Identification of the Most Accurate Spectral-domain Optical Coherence Tomography Parameters in Eyes With Early High-Tension and Low-Tension Glaucoma

被引:2
|
作者
Gracitelli, Carolina P. B. [1 ,3 ]
Moreno, Pilar A. [1 ,2 ]
Leite, Mauro T. [1 ]
Prata, Tiago S. [1 ,2 ]
机构
[1] Univ Fed Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
[2] Hosp Oftalmol Med Olhos, Osasco, Brazil
[3] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, 9500 Gilman Dr, La Jolla, CA 92093 USA
关键词
spectral-domain optical coherence tomography; ganglion cells; nerve fiber layer; NERVE-FIBER LAYER; GANGLION-CELL COMPLEX; VISUAL-FIELD SENSITIVITY; OPEN-ANGLE GLAUCOMA; OCULAR HYPERTENSION; FOURIER-DOMAIN; THICKNESS; DIAGNOSIS; DAMAGE; OCT;
D O I
10.1097/IJG.0000000000000406
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of the study was to compare the diagnostic ability of macular ganglion cell complex (GCC) and peripapillary retinal nerve fiber layer (pRNFL) thickness in high-tension glaucoma (HTG) and low-tension glaucoma (LTG). Patients and Methods: Glaucoma was defined as glaucomatous optic neuropathy and reproducible visual field defects. Patients were classified as having LTG if untreated intraocular pressure was <= 21mm Hg on 2 different occasions. Only eyes with early glaucoma (mean deviation < -6 dB) were included. All patients underwent spectral-domain optical coherence tomography (SDOCT) imaging. Results: A total of 56 normal subjects, 64 HTG patients, and 35 LTG patients were enrolled. Overall, after adjusting for mean deviation and age, the average pRNFL thickness in eyes with LTG was 18.7 mm thinner than in eyes with HTG (17% difference, P < 0.01). In the HTG group, no significant difference was found between areas under the receiver operating characteristic curve (AUCs) for average GCC and average pRNFL thicknesses (0.77 vs. 0.68, P = 0.06). In the LTG group, average pRNFL thickness had a significantly larger AUC compared with average GCC thickness (0.95 vs. 0.81, P < 0.001). Comparing AUCs between HTG and LTG groups, although the average GCC had similar AUCs in both groups (P = 0.47), the average pRNFL thickness had a significantly larger AUC in the LTG group (P < 0.001). Conclusions: In eyes with early glaucoma, the pRNFL thickness scan seems to be a more accurate SDOCT protocol to identify those with LTG compared with the GCC thickness scan.
引用
收藏
页码:854 / 859
页数:6
相关论文
共 50 条
  • [31] Longitudinal Analysis of Progression in Glaucoma Using Spectral-Domain Optical Coherence Tomography
    Wessel, Julia M.
    Horn, Folkert K.
    Tornow, Ralf P.
    Schmid, Matthias
    Mardin, Christian Y.
    Kruse, Friedrich E.
    Juenemann, Anselm G.
    Laemmer, Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (05) : 3613 - 3620
  • [32] Measurement of Photoreceptor Layer in Glaucoma: A Spectral-Domain Optical Coherence Tomography Study
    Fan, Ning
    Huang, Nina
    Lam, Dennis Shun Chiu
    Leung, Christopher Kai-shun
    JOURNAL OF OPHTHALMOLOGY, 2011, 2011
  • [33] Macular Imaging for Glaucoma Using Spectral-domain Optical Coherence Tomography: A Review
    Wong, Jessica J.
    Chen, Teresa C.
    Shen, Lucy Q.
    Pasquale, Louis R.
    SEMINARS IN OPHTHALMOLOGY, 2012, 27 (5-6) : 160 - 166
  • [34] Reproducibility of Spectral-Domain Optical Coherence Tomography Measurements in Adult and Pediatric Glaucoma
    Ghasia, Fatema F.
    El-Dairi, Mays
    Freedman, Sharon F.
    Rajani, Anand
    Asrani, Sanjay
    JOURNAL OF GLAUCOMA, 2015, 24 (01) : 55 - 63
  • [35] Likelihood Ratios for Glaucoma Diagnosis Using Spectral-Domain Optical Coherence Tomography
    Lisboa, Renato
    Mansouri, Kaweh
    Zangwill, Linda M.
    Weinreb, Robert N.
    Medeiros, Felipe A.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (05) : 918 - 926
  • [36] Evaluation of anterior chamber parameters with spectral-domain optical coherence tomography
    Isabel Pinilla Lozano
    Carmen López de la Fuente
    Francisco Segura
    Elvira Orduna Hospital
    Ana Sánchez-Cano
    Japanese Journal of Ophthalmology, 2018, 62 : 209 - 215
  • [37] Evaluation of anterior chamber parameters with spectral-domain optical coherence tomography
    Pinilla Lozano, Isabel
    Lopez de la Fuente, Carmen
    Segura, Francisco
    Orduna Hospital, Elvira
    Sanchez-Cano, Ana
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2018, 62 (02) : 209 - 215
  • [38] Spectral-Domain Optical Coherence Tomography for Early Detection of Hydroxychloroquine Toxicity
    Pandya, Hemang K.
    Porter, Hunter
    Shah, Vinay A.
    Mandal, Nawajes A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [39] Quantitative differences between the optic nerve head and peripapillary retina in low-tension and high-tension primary open-angle glaucoma
    Eid, TE
    Spaeth, GL
    Moster, MR
    Augsburger, JJ
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 124 (06) : 805 - 813
  • [40] Sensitivity and Specificity of Time-Domain versus Spectral-Domain Optical Coherence Tomography in Diagnosing Early to Moderate Glaucoma
    Chang, Robert T.
    Knight, O'Rese J.
    Feuer, William J.
    Budenz, Donald L.
    OPHTHALMOLOGY, 2009, 116 (12) : 2294 - 2299