Cone Beam Digital Tomosynthesis (CBDT): An alternative to Cone Beam Computed Tomography (CBCT) for image-guided radiation therapy

被引:5
|
作者
Pang, G
Au, P
O'Brien, P
Bani-Hashemi, A
Svatos, M
Rowlands, JA
机构
[1] Dept Radiat Oncol, Toronto, ON, Canada
[2] Univ Toronto, Dept Med Biophys, Sunnybrook & Womens Coll, Hlth Sci Ctr, Toronto, ON, Canada
[3] Toronto Sunnybrook Reg Canc Ctr, Toronto, ON, Canada
[4] Siemens Med Solut USA Inc, Concord, CA USA
关键词
D O I
10.1118/1.1998514
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the feasibility of using a new imaging technique, i.e., Cone Beam Digital Tomosynthesis (CBDT) as an alternative to the Cone Beam Computed Tomography (CBCT) approach for creating 3D cross sectional images of a patient in the radiotherapy treatment room. Method and Materials: Similar to the CBCT approach, the CBDT uses an x‐ray source (either a kV source or a MV source on a Linac or another radiation‐emitting device) and an x‐ray detector to acquire projection data by rotating them around a patient simultaneously. Unlike CBCT, CBDT utilizes partial scans, typically in the range of 20–60 degrees of gantry arc. The main advantage of the CBDT approach is that it takes less time to perform image acquisition and reconstruction. An experimental CBDT system has been built on a Linac with a recently developed flat‐panel detector. A novel filtered backprojection algorithm was developed for CBDT reconstructions. CBDT phantom images have been generated for different degrees of gantry arc and beamline configurations and compared to those from CBCT. Results: Cross‐sectional images of a Rando phantom were generated with comparable image quality to CBCT using as small as ∼ 22 degree gantry arc. The planes of CBDT reconstruction are orthogonal to the x‐ray beam at the midpoint of the arc. These reconstructed planes are of particular relevance to image‐guided radiation therapy, because they depict anatomy along planes that are most relevant to the treatment beam, i.e., orthogonal to the beam axis. Conclusion: We have demonstrated the feasibility of using CBDT to acquire cross‐sectional images of an object in the treatment room to guide radiotherapy treatment. Compared to CBCT, the CBDT approach is much faster with acceptable image quality in the planes most relevant to the treatment. Conflict of Interest: This work was supported by Siemens Medical Solutions USA, Inc. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2126 / 2126
页数:1
相关论文
共 50 条
  • [31] Investigating the Possibility of Using Cone Beam Computed Tomography (CBCT) for Radiation Therapy Treatment Planning
    E. N. Lykova
    E. P. Morozova
    S. S. Khromov
    A. P. Chernyaev
    Moscow University Physics Bulletin, 2021, 76 : 233 - 239
  • [32] Investigating the Possibility of Using Cone Beam Computed Tomography (CBCT) for Radiation Therapy Treatment Planning
    Lykova, E. N.
    Morozova, E. P.
    Khromov, S. S.
    Chernyaev, A. P.
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2021, 76 (04) : 233 - 239
  • [33] IMAGE-GUIDED RADIOTHERAPY (IGRT) FOR PROSTATE CANCER COMPARING kV IMAGING OF FIDUCIAL MARKERS WITH CONE BEAM COMPUTED TOMOGRAPHY (CBCT)
    Barney, Brandon M.
    Lee, R. Jeffrey
    Handrahan, Diana
    Welsh, Keith T.
    Cook, J. Taylor
    Sause, William T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (01): : 301 - 305
  • [34] Beam alignment and image distortion assessment of dental cone beam computed tomography (CBCT) system
    Rabba, J. A.
    Jaafar, H. A.
    Jafri, M. Z. M.
    Suhaimi, F. M.
    Osman, N. D.
    11TH INTERNATIONAL SEMINAR ON MEDICAL PHYSICS (ISMP) 2019, 2020, 1497
  • [35] Quantitative evaluation of a cone beam computed tomography (CBCT)-CT deformable image registration method for adaptive radiation therapy
    Lawson, J. D.
    Schreibmann, E.
    Jani, A. B.
    Fox, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S709 - S709
  • [36] Comparison of thermoplastic masks and knee wedge as immobilization devices for image-guided pelvic radiation therapy using Cone Beam Computed Tomography
    Anand, Mridul
    Parikh, Ankita
    Shah, Sonal
    INDIAN JOURNAL OF CANCER, 2020, 57 (02) : 182 - 186
  • [37] Quantitative evaluation of cone-beam computed tomography in target volume definition for offline image-guided radiation therapy of prostate cancer
    Wang, Weihu
    Wu, Qiuwen
    Yan, Di
    RADIOTHERAPY AND ONCOLOGY, 2010, 94 (01) : 71 - 75
  • [38] On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT)
    Bak, Jino
    Jeong, Kyoungkeun
    Keum, Ki Chang
    Park, Suk Won
    RADIATION ONCOLOGY JOURNAL, 2006, 24 (04): : 294 - 299
  • [39] Kilo-voltage cone-beam CT for image-guided radiation therapy
    Sonke, JJ
    Remeijer, P
    Betgen, A
    Lebesque, J
    van Herk, M
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S70 - S70
  • [40] Analysis of Interfractional Setup Variation with Image Guided Radiation Therapy Using KV Cone Beam Computed Tomography
    Choi, K.
    Lee, J.
    Yoon, J.
    Lee, J.
    Park, J.
    Suh, T.
    MEDICAL PHYSICS, 2011, 38 (06)