Experimental Investigation of Time-Frequency Characteristics of Pressure Fluctuations in a Double-Suction Centrifugal Pump

被引:93
|
作者
Yao, Zhifeng [1 ]
Wang, Fujun [1 ]
Qu, Lixia [1 ]
Xiao, Ruofu [1 ]
He, Chenglian [2 ]
Wang, Min [1 ]
机构
[1] China Agr Univ, Coll Water Conservancy & Civil Engn, Beijing 100083, Peoples R China
[2] Design & Res Co Ltd, China Water Beifang Invest, Tianjin 300222, Peoples R China
基金
中国国家自然科学基金; 北京市自然科学基金;
关键词
double-suction centrifugal pump; experimental investigation; pressure fluctuation; adaptive optimal kernel; time-frequency distribution; UNSTEADY-FLOW; DIFFUSER PUMP; IMPELLER; FIELD;
D O I
10.1115/1.4004959
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Pressure fluctuation is the primary reason for unstable operations of double-suction centrifugal pumps. By using flush mounted pressure transducers in the semispiral suction chamber and the volute casing of a double-suction pump, the pressure fluctuation signals were obtained and recorded at various operating conditions. Spectral analyses were performed on the pressure fluctuation signals in both frequency domain and time-frequency domain based on fast Fourier transform (FFT) and an adaptive optimal-kernel time-frequency representation (AOK TFR). The results show that pressure fluctuations at the impeller rotating frequency and some lower frequencies dominated in the semispiral suction chamber. Pressure fluctuations at the blade passing frequency, the impeller rotating frequency, and their harmonic frequencies were identified in the volute casing. The amplitude of pressure fluctuation at the blade passing frequency significantly increased when the flow rate deviated from the design flow rate. At 107% of the design flow rate, the amplitude increased more than 254% than that at the design flow rate. The time-frequency characteristics of these pressure fluctuations were affected greatly by both operating conditions and measurement locations. At partial flow rates the pulsation had a great irregularity and the amplitudes at the investigated frequencies were much larger than ones at the design flow rate. An asymmetrical pressure fluctuation structure in the volute casing was observed at all flow rates. The pulsation behavior at the blade passing frequency was the most prominent near the volute tongue zone, and the pressure waves propagated in both the radial and circumferential directions. [DOI: 10.1115/1.4004959]
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Numerical simulation on transient characteristics of double-suction centrifugal pump system during opening valve processes
    Li, Yaojun
    Zhu, Qiang
    Liu, Zhuqing
    Yang, Wei
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2015, 46 (12): : 74 - 81
  • [42] Numerical investigation of losses in a double-suction multistage centrifugal pump and its mitigation using baffle plates
    Shamsuddeen, Mohamed Murshid
    Kim, Sung
    Abu Shahzer, Mohammad
    Ma, Sang-Bum
    Kim, Jin-Hyuk
    FRONTIERS IN ENERGY RESEARCH, 2022, 10
  • [43] Mechanisms of performance degradation in a double-suction centrifugal pump under inflow distortions
    Wang, Wei
    Liu, Boxing
    Lu, Jinling
    Feng, Jianjun
    Zhang, Lefu
    Luo, Xingqi
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2023, 237 (03) : 680 - 689
  • [44] Alternative Design of Double-Suction Centrifugal Pump to Reduce the Effects of Silt Erosion
    Dong, Jing
    Qian, Zhongdong
    Thapa, Biraj Singh
    Thapa, Bhola
    Guo, Zhiwei
    ENERGIES, 2019, 12 (01)
  • [45] Effects of flow rate and silt particle on vibration of a double-suction centrifugal pump
    Wang, Zhiyuan
    Qian, Zhongdong
    2020 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ADVANCED RELIABILITY AND MAINTENANCE MODELING (APARM), 2020,
  • [46] Effects of concentration and size of silt particles on the performance of a double-suction centrifugal pump
    Wang, Zhiyuan
    Qian, Zhongdong
    ENERGY, 2017, 123 (123) : 36 - 46
  • [47] DMD Analysis of Unsteady Flow of Impeller in Double-suction Centrifugal Pump as Turbine
    Miao S.
    Liu L.
    Wang X.
    Yang J.
    Wu J.
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2024, 55 (06): : 150 - 158
  • [48] Erosion Wear on Impeller of Double-Suction Centrifugal Pump due to Sediment Flow
    Shen, Z.
    Li, R.
    Han, W.
    Quan, H.
    Guo, R.
    JOURNAL OF APPLIED FLUID MECHANICS, 2020, 13 (04) : 1131 - 1142
  • [49] Energy loss analysis of a double-suction centrifugal pump using in pump mode and turbine mode
    Lei, Lei
    Wang, Tao
    Qiu, Bo
    Liu, Yunqi
    Yu, He
    Huang, Tengfei
    PHYSICS OF FLUIDS, 2024, 36 (06)
  • [50] Investigation of energy dissipation mechanism and the influence of vortical structures in a high-power double-suction centrifugal pump
    Deng, Qifan
    Pei, Ji
    Wang, Wenjie
    Sun, Ju
    PHYSICS OF FLUIDS, 2023, 35 (07)