Indoor radon measurements in dwellings of Kulu area, Himachal Pradesh, using solid state nuclear track detectors

被引:42
|
作者
Singh, S [1 ]
Malhotra, R [1 ]
Kumar, J [1 ]
Singh, L [1 ]
机构
[1] Guru Nanak Dev Univ, Dept Phys, Amritsar 143005, Punjab, India
关键词
indoor radon; LR-115 type II films; etching;
D O I
10.1016/S1350-4487(01)00216-5
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In the present paper, the results of radon activity recorded in domestic regions of the Kulu area (Himachal Pradesh, India) known for uranium mineralisation are reported. Time integrated track etch technique has been used for the measurement of indoor radon levels. Bare cellulose nitrate LR-115 type II films have been used as detectors in the survey of radon. The calibration constant of 4.8 x 10(2) tracks cm(-2) day(-1) per WL of radon at equilibrium (which corresponds to 12.97 x 10(-2) tracks cm(-2) d(-1) per Bq m(-3)) determined by Subba Ramu et al. (Sci. Total Environ. 73 (1988) 245) has been used to express radon activity in Bq m(-3). In some of the dwellings the levels of radon activity are found to be quite high giving an annual exposure dose that crosses the safety limits set by the International Commission on Radiological Protection (ICRP, Protection against radon-222 at home and at work, ICRP Publication 65, Annals of the ICRP, 23 (2), 1993). A study of seasonal variations of indoor radon in some of the dwellings has also been carried out. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:505 / 508
页数:4
相关论文
共 50 条
  • [41] Radon emanation and uranium content in an endokarstic formation using solid state nuclear track detectors
    Oufni, L
    Misdaq, MA
    JOURNAL DE PHYSIQUE IV, 2005, 123 : 377 - 380
  • [42] Study of radon exhalation rates from coal using solid state nuclear track detectors
    Pranjal P. Gogoi
    Debajyoti Barooah
    Journal of Radioanalytical and Nuclear Chemistry, 2022, 331 : 1959 - 1965
  • [43] Assessing radon adsorption capacity in adsorbents using solid state nuclear track detectors (SSNTDs)
    Pressyanov, Dobromir S.
    RADIATION MEASUREMENTS, 2024, 176
  • [44] A study of radon emitted from building materials using solid state nuclear track detectors
    Amin, Rafat M.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2015, 8 (04) : 516 - 522
  • [45] Study of radon exhalation rates from coal using solid state nuclear track detectors
    Gogoi, Pranjal P.
    Barooah, Debajyoti
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2022, 331 (04) : 1959 - 1965
  • [46] Radon diffusion studies in some building materials using solid state nuclear track detectors
    Singh, S
    Kumar, J
    Singh, B
    Singh, J
    RADIATION MEASUREMENTS, 1999, 30 (04) : 461 - 464
  • [47] Study of indoor radon levels in Garhwal Himalayas using solid state nuclear track detector
    Ramola, RC
    RADON AND THORON IN THE HUMAN ENVIRONMENT, 1998, : 367 - 372
  • [48] Comparison of radon measurements done by solid state nuclear track detectors and electronic devices in the framework of an EU-radon project
    Jonsson, G
    Albarracin, D
    Bacmeister, GU
    Baixeras, C
    Climent, H
    Cotellessa, G
    Devantier, R
    Enge, W
    Freyer, K
    Font, LL
    Ghose, R
    Monnin, MM
    Sciocchetti, G
    Seidel, JL
    Treutler, HC
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 651 - 656
  • [49] RADON AND THORON DOSIMETRY BY PLASTIC SOLID-STATE NUCLEAR TRACK DETECTORS
    KHAN, HA
    AKBER, RA
    BUKHARI, KM
    SADDARUDIN, A
    NUCLEAR INSTRUMENTS & METHODS, 1977, 147 (01): : 125 - 131
  • [50] APPLICATION OF NUCLEAR TRACK DETECTORS FOR RADON RELATED MEASUREMENTS
    ABUJARAD, FA
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1988, 15 (1-4): : 525 - 534