3-dimensional dosimetry;
radioimmunotherapy;
SPECT;
Monte Carlo dosimetry;
I-131;
D O I:
暂无
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
I-131 radionuclide therapy studies have not shown a strong relationship between tumor absorbed dose and response, possibly due to inaccuracies in activity quantification and dose estimation. The goal of this work was to establish the accuracy of I-131 activity quantification and absorbed dose estimation when patient-specific, 3-dimensional (3D) methods are used for SPECT reconstruction and for absorbed dose calculation. Methods: Clinically realistic voxel-phantom simulations were used in the evaluation of activity quantification and dosimetry. SPECT reconstruction was performed using an ordered-subsets expectation maximization (OSEM) algorithm with compensation for scatter, attenuation, and 3D detector response. Based on the SPECT image and a patient-specific density map derived from CT, 3D dosimetry was performed using a newly implemented Monte Carlo code. Dosimetry was evaluated by comparing mean absorbed dose estimates calculated directly from the defined phantom activity map with those calculated from the SPECT image of the phantom. Finally, the 3D methods were applied to a radioimmunotherapy patient, and the mean tumor absorbed dose from the new calculation was compared with that from conventional dosimetry obtained from conjugate-view imaging. Results: Overall, the accuracy of the SPECT-based absorbed dose estimates in the phantom was > 12% for targets down to 16 mL and up to 35% for the smallest 7-mL tumor. To improve accuracy in the smallest tumor, more OSEM iterations may be needed. The relative SD from multiple realizations was < 3% for all targets except for the smallest tumor. For the patient, the mean tumor absorbed dose estimate from the new Monte Carlo calculation was 7% higher than that from conventional dosimetry. Conclusion: For target sizes down to 16 mL, highly accurate and precise dosimetry can be obtained with 3D methods for SPECT reconstruction and absorbed dose estimation. In the future, these methods can be applied to patients to potentially establish correlations between tumor regression and the absorbed dose statistics from 3D dosimetry.
机构:
Bhabha Atom Res Ctr, Tata Mem Ctr Annexe, Radiat Med Ctr, Mumbai, Maharashtra, India
Homi Bhabha Natl Inst, Mumbai, Maharashtra, IndiaBhabha Atom Res Ctr, Tata Mem Ctr Annexe, Radiat Med Ctr, Mumbai, Maharashtra, India
Adnan, Aadil
Deep, Kamal
论文数: 0引用数: 0
h-index: 0
机构:
Homi Bhabha Natl Inst, Mumbai, Maharashtra, India
Cama & Albless Hosp, Radiat Safety Syst Div, Mumbai, Maharashtra, IndiaBhabha Atom Res Ctr, Tata Mem Ctr Annexe, Radiat Med Ctr, Mumbai, Maharashtra, India
Deep, Kamal
Kameswaran, Mythilli
论文数: 0引用数: 0
h-index: 0
机构:
Homi Bhabha Natl Inst, Mumbai, Maharashtra, India
Cama & Albless Hosp, Radiopharmaceut Div, Mumbai, Maharashtra, IndiaBhabha Atom Res Ctr, Tata Mem Ctr Annexe, Radiat Med Ctr, Mumbai, Maharashtra, India
Kameswaran, Mythilli
Nikam, Dilip
论文数: 0引用数: 0
h-index: 0
机构:
Cama & Albless Hosp, Dept Radiotherapy & Oncol, Mumbai, Maharashtra, IndiaBhabha Atom Res Ctr, Tata Mem Ctr Annexe, Radiat Med Ctr, Mumbai, Maharashtra, India
Nikam, Dilip
Shanmukaih, Chandrakala
论文数: 0引用数: 0
h-index: 0
机构:
King Edward Mem Hosp, Dept Hematol, Mumbai, Maharashtra, IndiaBhabha Atom Res Ctr, Tata Mem Ctr Annexe, Radiat Med Ctr, Mumbai, Maharashtra, India
Shanmukaih, Chandrakala
Dash, Ashutosh
论文数: 0引用数: 0
h-index: 0
机构:
Homi Bhabha Natl Inst, Mumbai, Maharashtra, India
Cama & Albless Hosp, Radiopharmaceut Div, Mumbai, Maharashtra, IndiaBhabha Atom Res Ctr, Tata Mem Ctr Annexe, Radiat Med Ctr, Mumbai, Maharashtra, India
Dash, Ashutosh
Banerjee, Sharmila
论文数: 0引用数: 0
h-index: 0
机构:
Bhabha Atom Res Ctr, Tata Mem Ctr Annexe, Radiat Med Ctr, Mumbai, Maharashtra, India
Homi Bhabha Natl Inst, Mumbai, Maharashtra, IndiaBhabha Atom Res Ctr, Tata Mem Ctr Annexe, Radiat Med Ctr, Mumbai, Maharashtra, India
Banerjee, Sharmila
Basu, Sandip
论文数: 0引用数: 0
h-index: 0
机构:
Bhabha Atom Res Ctr, Tata Mem Ctr Annexe, Radiat Med Ctr, Mumbai, Maharashtra, India
Homi Bhabha Natl Inst, Mumbai, Maharashtra, IndiaBhabha Atom Res Ctr, Tata Mem Ctr Annexe, Radiat Med Ctr, Mumbai, Maharashtra, India