Accurate dosimetry in 131I radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation

被引:0
|
作者
Dewaraja, YK
Wilderman, SJ
Ljungberg, M
Koral, KF
Zasadny, K
Kaminiski, MS
机构
[1] Univ Michigan, Med Ctr, Dept Radiol, Div Nucl Med, Ann Arbor, MI 48109 USA
[2] Lund Univ, Dept Med Radiat Phys, S-22100 Lund, Sweden
[3] Pfizer Global Res & Dev, Ann Arbor, MI USA
[4] Univ Michigan, Med Ctr, Dept Internal Med, Div Hematol & Oncol, Ann Arbor, MI 48109 USA
关键词
3-dimensional dosimetry; radioimmunotherapy; SPECT; Monte Carlo dosimetry; I-131;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
I-131 radionuclide therapy studies have not shown a strong relationship between tumor absorbed dose and response, possibly due to inaccuracies in activity quantification and dose estimation. The goal of this work was to establish the accuracy of I-131 activity quantification and absorbed dose estimation when patient-specific, 3-dimensional (3D) methods are used for SPECT reconstruction and for absorbed dose calculation. Methods: Clinically realistic voxel-phantom simulations were used in the evaluation of activity quantification and dosimetry. SPECT reconstruction was performed using an ordered-subsets expectation maximization (OSEM) algorithm with compensation for scatter, attenuation, and 3D detector response. Based on the SPECT image and a patient-specific density map derived from CT, 3D dosimetry was performed using a newly implemented Monte Carlo code. Dosimetry was evaluated by comparing mean absorbed dose estimates calculated directly from the defined phantom activity map with those calculated from the SPECT image of the phantom. Finally, the 3D methods were applied to a radioimmunotherapy patient, and the mean tumor absorbed dose from the new calculation was compared with that from conventional dosimetry obtained from conjugate-view imaging. Results: Overall, the accuracy of the SPECT-based absorbed dose estimates in the phantom was > 12% for targets down to 16 mL and up to 35% for the smallest 7-mL tumor. To improve accuracy in the smallest tumor, more OSEM iterations may be needed. The relative SD from multiple realizations was < 3% for all targets except for the smallest tumor. For the patient, the mean tumor absorbed dose estimate from the new Monte Carlo calculation was 7% higher than that from conventional dosimetry. Conclusion: For target sizes down to 16 mL, highly accurate and precise dosimetry can be obtained with 3D methods for SPECT reconstruction and absorbed dose estimation. In the future, these methods can be applied to patients to potentially establish correlations between tumor regression and the absorbed dose statistics from 3D dosimetry.
引用
收藏
页码:840 / 849
页数:10
相关论文
共 33 条
  • [31] Biodistribution and Dosimetry of Indigenously Produced 131I-Rituximab in B-Cell Lymphoma: Pilot Study Estimating Patient-Specific Dose Comparing 2 Different Dosimetric Methods
    Adnan, Aadil
    Deep, Kamal
    Kameswaran, Mythilli
    Nikam, Dilip
    Shanmukaih, Chandrakala
    Dash, Ashutosh
    Banerjee, Sharmila
    Basu, Sandip
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2019, 47 (04) : 292 - 299
  • [32] Development of Patient-specific 3-dimensional (3D) Dose Real Evaluation Systems Using a Novel Patient-based 3D Dose Scanner (P3DS) in Tomotherapy
    Lee, S.
    Shim, J.
    Chang, K.
    Cao, Y.
    Kim, J.
    Ko, J.
    Jeong, H.
    Yang, D.
    Park, Y.
    Kim, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S770 - S770
  • [33] Validation of Monte Carlo Simulated Tc-99m Absorbed-Dose-To-Water Inside a Custom SPECT/CT Phantom Using Active and Passive Dosimeters: A Novel Approach to Benchmarking Monte Carlo Methods for Targeted Radionuclide Therapy Dosimetry
    Bertinetti, A.
    Rodrigues, M.
    Palmer, B.
    Hammer, C.
    Hull, J.
    Vija, H.
    Culberson, W.
    MEDICAL PHYSICS, 2021, 48 (06)