The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a finite element study

被引:152
|
作者
Hansson, S
Werke, M
机构
[1] Astra Tech AB, Dept Res & Dev, S-43121 Molndal, Sweden
[2] Swedish Inst Prod Engn Res, S-43153 Molndal, Sweden
关键词
thread profile; thread size; stress; bone; implant; SINGLE TOOTH IMPLANTS; CONICAL FIXTURE DESIGN; ORAL IMPLANTS; FIXATION; BEHAVIOR; SMOOTH; TISSUE; STRAIN;
D O I
10.1016/S0021-9290(03)00164-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Assuming that high stress peaks in the bone can trigger bone resorption a screw-shaped bone implant should be given such a design that the peak stresses arising in the bone, as a result of a certain load, are minimized. Using idealized assumptions the aim of the study was to analyse the effect of variations of the size and the profile of the thread of an axially loaded, screw-shaped, bone implant upon the magnitude of the stress peaks in cortical bone. The investigation was performed by means of axisymmetric finite element analysis. It was found that the shape of the thread profile has a profound effect upon the magnitude of the stresses in the bone and that very small threads of a favourable profile can be quite effective. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1247 / 1258
页数:12
相关论文
共 50 条
  • [41] Thread Forming of a Micro Screw for Storage Devices using Finite Element Analysis
    Lee, H. W.
    Song, J. H.
    Lee, G. A.
    Lee, H. J.
    Park, K. D.
    ADVANCES IN MATERIALS AND PROCESSING TECHNOLOGIES II, PTS 1 AND 2, 2011, 264-265 : 1613 - +
  • [42] Acceleration of finite element analysis by PC cluster with broadcast and multi-thread
    Matsuda, A
    Miyakawa, Y
    Ichikawa, M
    Kato, T
    SIMULATION OF MATERIALS PROCESSING: THEORY, METHODS AND APPLICATIONS, 2001, : 183 - 187
  • [43] The effect of thread pattern upon implant osseointegration
    Abuhussein, Heba
    Pagni, Giorgio
    Rebaudi, Alberto
    Wang, Hom-Lay
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (02) : 129 - 136
  • [44] Study on a New Forming Method-Thread Rolling by Crystal Plasticity Finite Element Simulation
    Zhang, Yuheng
    Hu, Zhiqing
    Guo, Liming
    METALS, 2021, 11 (03) : 1 - 16
  • [45] Effects of custom-made and thread dental implant systems on the stress distribution in alveolar bone: a 3-dimensional finite element analysis
    Zhang, Xiao
    Xie, Zhangong
    Feng, Wei
    Chen, Xianshuai
    Chen, Jianyu
    SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS II, PTS 1 AND 2, 2014, 475-476 : 1487 - +
  • [46] Three-Dimensional Finite Element Investigation into Effects of Implant Thread Design and Loading Rate on Stress Distribution in Dental Implants and Anisotropic Bone
    Alemayehu, Dawit-Bogale
    Jeng, Yeau-Ren
    MATERIALS, 2021, 14 (22)
  • [47] Dental implant thread profile optimization using Taguchi approach
    Khened, Vineet
    Bhandarkar, Shubham
    Dhatrak, Pankaj
    MATERIALS TODAY-PROCEEDINGS, 2022, 62 : 3344 - 3349
  • [48] Effect of Thread Design Parameters on Central Screw Loosening: A 3D Finite Element Analysis
    Xu, Liang-wei
    Cheng, Kang-jie
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2024, 44 (04) : 556 - 564
  • [49] Finite Element Modeling And Simulation For Vibration-assisted Extrusion Tapping Of Internal Thread
    Li, Y. Y.
    Zhao, S. D.
    4TH MANUFACTURING ENGINEERING SOCIETY INTERNATIONAL CONFERENCE (MESIC 2011), 2012, 1431 : 711 - 718
  • [50] Three-dimensional finite element analysis of the mechanical properties of helical thread connection
    Yang Guoqing
    Hong Jun
    Zhu Linbo
    Li Baotong
    Xiong Meihua
    Wang Fei