The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a finite element study

被引:152
|
作者
Hansson, S
Werke, M
机构
[1] Astra Tech AB, Dept Res & Dev, S-43121 Molndal, Sweden
[2] Swedish Inst Prod Engn Res, S-43153 Molndal, Sweden
关键词
thread profile; thread size; stress; bone; implant; SINGLE TOOTH IMPLANTS; CONICAL FIXTURE DESIGN; ORAL IMPLANTS; FIXATION; BEHAVIOR; SMOOTH; TISSUE; STRAIN;
D O I
10.1016/S0021-9290(03)00164-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Assuming that high stress peaks in the bone can trigger bone resorption a screw-shaped bone implant should be given such a design that the peak stresses arising in the bone, as a result of a certain load, are minimized. Using idealized assumptions the aim of the study was to analyse the effect of variations of the size and the profile of the thread of an axially loaded, screw-shaped, bone implant upon the magnitude of the stress peaks in cortical bone. The investigation was performed by means of axisymmetric finite element analysis. It was found that the shape of the thread profile has a profound effect upon the magnitude of the stresses in the bone and that very small threads of a favourable profile can be quite effective. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1247 / 1258
页数:12
相关论文
共 50 条
  • [1] The Effect of Dental Implant Materials and Thread Profiles-A Finite Element and Statistical Study
    Shafi, Aisyah Ahmad
    Kadir, Mohammed Rafiq Abdul
    Sulaiman, Eshamsul
    Abu Kasim, Noor Hayaty
    Abu Kassim, Noor Lide
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2013, 3 (04) : 509 - 513
  • [2] Finite element method simulation of thread off failure on casing thread connection
    Wang, L.
    Chen, Z.N.
    Tong, D.C.
    Zou, J.X.
    Zang, Y.
    Beijing Keji Daxue Xuebao/Journal of University of Science and Technology Beijing, 2001, 23 (02):
  • [3] Impact of screw thread shape on stress transfer in bone: a finite element study
    Tetteh, Emmanuel
    McCullough, Matthew B. A.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 (09) : 518 - 523
  • [4] The Effect of Implant Thread Design on Stress Distribution in Anisotropic Bone with Different Osseointegration Conditions: A Finite Element Analysis
    Mosavar, Alireza
    Ziaei, Alireza
    Kadkhodaei, Mahmoud
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (06) : 1317 - 1326
  • [5] Finite element modeling of external thread rolling
    Domblesky, J.P.
    Feng, F.
    Wire Industry, 2001, 68 (814): : 110 - 115
  • [6] A study of the helical effect on the thread connection by three dimensional finite element analysis
    Chen, JJ
    Shih, YS
    NUCLEAR ENGINEERING AND DESIGN, 1999, 191 (02) : 109 - 116
  • [7] The effect of thread geometry on the stress distribution in the bone around implant: 2-D finite element analysis.
    Salimee, P
    Thanapalin, T
    Dechaumphai, P
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 648 - 648
  • [8] Analysis of the Effect of Thread Depth in Four Different Thread Designs on the Stress Distribution at the Implant-bone Interface Using Finite Element Analysis - A Comparative Three-Dimensional In vitro Study
    Patwari, Swati
    Sahu, Jeeban
    Samanta, Satyaki
    Bharti, Shreya
    Saha, Dipanwita
    Manna, Rohan
    JOURNAL OF THE INTERNATIONAL CLINICAL DENTAL RESEARCH ORGANIZATION, 2024, 16 (01) : 48 - 54
  • [9] New Finite-Element Model of Thread Rolling
    Lee, MinCheol
    Jang, SooJin
    Han, SeungSang
    Yoon, DukJae
    Joun, ManSoo
    STEEL RESEARCH INTERNATIONAL, 2010, 81 (09) : 214 - 217
  • [10] Finite element analysis of thread stripping of a threaded assembly
    Martínez-Martínez, M
    Ferrand, A
    Guillot, J
    COMPUTATIONAL METHODS IN CONTACT MECHANICS V, 2001, 5 : 263 - 272