A novel anthropomorphic multimodality phantom for MRI-based radiotherapy quality assurance testing

被引:21
|
作者
Singhrao, Kamal [1 ]
Fu, Jie [1 ]
Wu, Holden H. [2 ]
Hu, Peng [2 ]
Kishan, Amar U. [1 ]
Chin, Robert K. [1 ]
Lewis, John H. [3 ]
机构
[1] Univ Calif Los Angeles, Dept Radiat Oncol, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Dept Radiol, Los Angeles, CA 90095 USA
[3] Cedars Sinai Med Ctr, Dept Radiat Oncol, Los Angeles, CA 90048 USA
关键词
anthropomorphic; MRI; multimodality; phantom; QA; radiotherapy; RADIATION-THERAPY; RELAXATION-TIMES; PROSTATE RADIOTHERAPY; IN-VIVO; CT; TISSUE; SYSTEM; SCANS; 1.5T;
D O I
10.1002/mp.14027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Increased utilization of magnetic resonance imaging (MRI) in radiotherapy has caused a growing need for phantoms that provide tissue-like contrast in both computed tomography (CT) and MRI images. Such phantoms can be used to compare MRI-based processes with CT-based clinical standards. Here, we develop and demonstrate the clinical utility of a three-dimensional (3D)-printed anthropomorphic pelvis phantom containing materials capable of T-1, T-2, and electron density matching for a clinically relevant set of soft tissues and bone. Methods The phantom design was based on a male pelvic anatomy template with thin boundaries separating tissue types. Slots were included to allow insertion of various dosimeters. The phantom structure was created using a 3D printer. The tissue compartments were filled with carrageenan-based materials designed to match the T-1 and T-2 relaxation times and electron densities of the corresponding tissues. CT and MRI images of the phantom were acquired and used to compare phantom T-1 and T-2 relaxation times and electron densities to literature-reported values for human tissue. To demonstrate clinical utility, the phantom was used for end-to-end testing of an MRI-only treatment simulation and planning workflow. Based on a T-2-weighted MRI image, synthetic CT (sCT) images were created using a statistical decomposition algorithm (MRIPlanner, Spectronic Research AB, Sweden) and used for dose calculation of volumetric-modulated arc therapy (VMAT) and seven-field intensity-modulated radiation therapy (IMRT) prostate plans. The plans were delivered on a Truebeam STX (Varian Medical Systems, Palo Alto, CA), with film and a 0.3 cc ion chamber used to measure the delivered dose. Doses calculated on the CT and sCTs were compared using common dose volume histogram metrics. Results T-1 and T-2 relaxation time and electron density measurements for the muscle, prostate, and bone agreed well with literature-reported in vivo measurements. Film analysis resulted in a 99.7% gamma pass rate (3.0%, 3.0 mm) for both plans. The ion chamber-measured dose discrepancies at the isocenter were 0.36% and 1.67% for the IMRT and VMAT plans, respectively. The differences in PTV D98% and D95% between plans calculated on the CT and 1.5T/3.0 T-derived sCT images were under 3%. Conclusion The developed phantom provides tissue-like contrast on MRI and CT and can be used to validate MRI-based processes through comparison with standard CT-based processes.
引用
收藏
页码:1443 / 1451
页数:9
相关论文
共 50 条
  • [41] Phantom-based quality assurance for multicenter quantitative MRI in locally advanced cervical cancer
    van Houdt, Petra J.
    Kallehauge, Jesper F.
    Tanderup, Kari
    Nout, Remi
    Zaletelj, Marko
    Tadic, Tony
    van Kesteren, Zdenko J.
    van den Berg, Cornelius A. T.
    Georg, Dietmar
    Cote, Jean-Charles
    Levesque, Ives R.
    Swamidas, Jamema
    Malinen, Eirik
    Telliskivi, Sven
    Brynolfsson, Patrik
    Mahmood, Faisal
    van der Heide, Uulke A.
    RADIOTHERAPY AND ONCOLOGY, 2020, 153 : 114 - 121
  • [42] Quality Assurance of Clinical MRI Scanners Using ACR MRI Phantom: Preliminary Results
    Chien-Chuan Chen
    Yung-Liang Wan
    Yau-Yau Wai
    Ho-Ling Liu
    Journal of Digital Imaging, 2004, 17 : 279 - 284
  • [43] MR Simulator Quality Assurance Technique Using an ACR MRI Phantom Based on 3D MR Sequence to Accommodate Radiotherapy Applications
    Ho, C.
    Wong, O.
    Yuan, J.
    Cheung, K.
    Yu, S.
    MEDICAL PHYSICS, 2018, 45 (06) : E544 - E544
  • [44] Reproducible phantom for quality assurance in abdominal MRI focussing kidney imaging
    Wolf, Marcos
    Kommer, Stefan
    Fembek, Sebastian
    Droeszler, Uwe
    Koerner, Tito
    Berg, Andreas
    Schmid, Albrecht Ingo
    Moser, Ewald
    Meyerspeer, Martin
    FRONTIERS IN PHYSICS, 2022, 10
  • [45] AUTOMATED LOW CONTRAST DETECTION FOR ACR MRI PHANTOM QUALITY ASSURANCE
    Madamesila, Joseph
    Golestani, Ali
    RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S136 - S137
  • [46] An Evaluation of Fiducial Marker Visibility for MR-Guided Radiotherapy in a 3D-Printed Anthropomorphic Multimodality Phantom
    Singhrao, K.
    Gao, Y.
    Fu, J.
    Guo, M.
    Yang, Y.
    Hu, P.
    Kishan, A.
    King, C.
    Lewis, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E442 - E442
  • [47] Multimodality MRI-based radiomics for aggressiveness prediction in papillary thyroid cancer
    Dai, Zedong
    Wei, Ran
    Wang, Hao
    Hu, Wenjuan
    Sun, Xilin
    Zhu, Jie
    Li, Hong
    Ge, Yaqiong
    Song, Bin
    BMC MEDICAL IMAGING, 2022, 22 (01)
  • [48] Multimodality MRI-based radiomics for aggressiveness prediction in papillary thyroid cancer
    Zedong Dai
    Ran Wei
    Hao Wang
    Wenjuan Hu
    Xilin Sun
    Jie Zhu
    Hong Li
    Yaqiong Ge
    Bin Song
    BMC Medical Imaging, 22
  • [49] Segmentation precision of abdominal anatomy for MRI-based radiotherapy
    Noel, Camille E.
    Zhu, Fan
    Lee, Andrew Y.
    Hu, Yanle
    Parikh, Parag J.
    MEDICAL DOSIMETRY, 2014, 39 (03) : 212 - 217
  • [50] CBCT and MRI-based workflows for online adaptive radiotherapy
    Behrens, C. P.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S857 - S857