Emergency Face-Mask Removal Effectiveness: A Comparison of Traditional and Nontraditional Football Helmet Face-Mask Attachment Systems

被引:6
|
作者
Swartz, Erik E. [1 ]
Belmore, Keith [2 ]
Decoster, Laura C. [3 ]
Armstrong, Charles W. [4 ]
机构
[1] Univ New Hampshire, Dept Kinesiol, Durham, NH 03824 USA
[2] Plymouth State Univ, Plymouth, NH USA
[3] New Hampshire Musculoskeletal Inst, Manchester, NH USA
[4] Univ Toledo, Toledo, OH USA
关键词
spine injuries; protective equipment; emergency management; COMBINED TOOL APPROACH; MOVEMENT; EFFICIENCY; PLAYERS; MOTION;
D O I
10.4085/1062-6050-45.6.560
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Context: Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. Objective: To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Design: Controlled laboratory study. Setting: Applied biomechanics laboratory. Participants: Twenty-five certified athletic trainers. Intervention(s): The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (OR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a backup cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Main Outcome Measure(s): Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (alpha = .05) with follow-up comparisons to test for differences. Results: Removal success was 100% (48 of 48) for OR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F(4,20) = 48.87, P = .001), with times ranging from 33.96 +/- 14.14 seconds for QR to 99.22 +/- 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F(4,20) = 16.25, P = .001), with range of motion from 10.10 degrees +/- 3.07 degrees for OR to 16.91 degrees +/- 5.36 degrees for TradAlt. Differences also were detected in RPE during face-mask removal (F(4,20) = 43.20, P = .001), with participants reporting average perceived difficulty ranging from 1.44 +/- 1.19 for OR to 3.68 +/- 1.70 for TradAlt. Conclusions: The OR and Trad trials resulted in superior results. When trials required cutting loop straps, results deteriorated.
引用
收藏
页码:560 / 569
页数:10
相关论文
共 50 条
  • [41] Comparison of chamber and face-mask 6.6-hour exposures to ozone on pulmonary function and symptoms responses
    Adams, WC
    INHALATION TOXICOLOGY, 2002, 14 (07) : 745 - 764
  • [42] Effect of a short training on neonatal face-mask ventilation performance in a low resource setting
    Mazza, Alessandro
    Cavallin, Francesco
    Cappellari, Anita
    Divisic, Antuan
    Grbin, Ivana
    Akakpo, Jean
    Moukaila, Abdou Razak
    Trevisanuto, Daniele
    PLOS ONE, 2017, 12 (10):
  • [43] NONINVASIVE FACE-MASK MECHANICAL VENTILATION IN PATIENTS WITH ACUTE HYPERCAPNIC RESPIRATORY-FAILURE
    ABOUSHALA, N
    MEDURI, GU
    CHEST, 1993, 103 (04) : 1304 - 1305
  • [44] CONTINUOUS POSITIVE AIRWAY PRESSURE APPLIED BY MEANS OF A TIGHT-FITTING FACE-MASK
    ACKERMAN, BD
    STEIN, MP
    SOMMER, JS
    SCHUMACHER, M
    JOURNAL OF PEDIATRICS, 1974, 85 (03): : 408 - 411
  • [45] A framework for effective face-mask contact modeling based on finite element analysis for custom design of a facial mask
    Kwon, Yun-Jae
    Kim, Jin-Gyun
    Lee, Wonsup
    PLOS ONE, 2022, 17 (07):
  • [46] A BEARDED FACE-MASK HELMET FROM THE COLLECTION OF THE NATIONAL MUSEUM IN BELGRADE AN EXAMPLE OF MUTUAL INFLUENCES OF ARMAMENT TRADITIONS AT THE ROMAN FRONTIER
    Negin, Andrey E.
    ARCHAOLOGISCHES KORRESPONDENZBLATT, 2015, 45 (04): : 535 - 547
  • [47] Face mask removal is safer than helmet removal for emergent airway access in American football
    Swartz, Erik E.
    Mihalik, Jason P.
    Beltz, Nora M.
    Day, Molly A.
    Decoster, Laura C.
    SPINE JOURNAL, 2014, 14 (06): : 996 - 1004
  • [48] The efficiency of tools used to retract a football helmet face mask
    Knox, KE
    Kleiner, DM
    JOURNAL OF ATHLETIC TRAINING, 1997, 32 (03) : 211 - 215
  • [49] Binasopharyngeal airway: a useful dedicated airway device in both elective and emergency difficult or impossible face-mask ventilation scenarios
    Jain, A.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 116 (06) : E897 - E897
  • [50] Combined tool approach is 100% successful for emergency football face mask removal
    Copeland, Aaron J.
    Decoster, Laura C.
    Swartz, Erik E.
    Gattie, Eric R.
    Gale, Stephanie D.
    CLINICAL JOURNAL OF SPORT MEDICINE, 2007, 17 (06): : 452 - 457