In vivo quantitative measurement of posterior capsule opacification after extracapsular cataract surgery

被引:73
|
作者
Hayashi, K
Hayashi, H
Nakao, F
Hayashi, F
机构
[1] Hayashi Eye Hosp, Hakata Ku, Fukuoka 812, Japan
[2] Fukuoka Univ, Sch Med, Dept Ophthalmol, Fukuoka 81401, Japan
关键词
D O I
10.1016/S0002-9394(98)00042-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To introduce a new in vivo quantitative measurement of posterior capsule opacification (PCO) after extracapsular cataract surgery and also to analyze the correlation between opacification density and the patient's visual acuity. METHODS: Prospectively, the opacification density value in the central 3-mm portion of the posterior capsule was quantitated by means of an area densitometry with the Scheimpflug photography system (EAS-1000). The EAS-1000 examination was performed on 40 eyes with clinically significant PCO both before and after undergoing Nd:YAG laser posterior capsulotomy, and on 10 eyes without PCO. The correlation between the opacification density value and the visual acuity was analyzed with a linear regression analysis. RESULTS: The mean opacification density values +/- SD were 48.8 +/- 29.5 computer-compatible tapes (CCT) steps in the PCO group before capsulotomy, 15.5 +/- 7.8 CCT steps in the PCO group after capsulotomy, and 12.9 +/- 4.9 CCT steps in the non-PCO group. The mean opacification density value in the PCO group before capsulotomy was significantly greater than that in the PCO group after capsulotomy or than that of the non-PCO group. A linear regression analysis determined that the opacification density value also correlated well with the visual acuity (R-2 = .808). CONCLUSIONS: We have established a new in vivo quantitative measurement of PCO. Because the opacification density value obtained by this measurement correlated well with the patient's visual acuity, we consider this measurement to be useful in both the research and clinical management of PCO. (C) 1998 by Elsevier Science Inc. All rights reserved.).
引用
收藏
页码:837 / 843
页数:7
相关论文
共 50 条
  • [41] Comparison of posterior capsule opacification after two different surgical methods of cataract extraction
    Nekolova, Jana
    Pozlerova, Jana
    Jiraskova, Nada
    Rozsival, Pavel
    Kadlecova, Jana
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (03) : 493 - 498
  • [42] Posterior capsule opacification in association with the cataract type and pseudoexfoliation.
    Amariotakis, AG
    Patsea, LE
    Parikakis, E
    Katsourakis, S
    Roungas, K
    Skouriotis, S
    Vourexaki, M
    Georgopoulos, GT
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S285 - S285
  • [43] Research Progress of Drug Prophylaxis for Lens Capsule Opacification after Cataract Surgery
    Zhang, Rong-Pei
    Xie, Zheng-Gao
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [44] Posterior capsule opacification in pediatric eyes with and without traumatic cataract
    Trivedi, Rupal H.
    Wilson, M. Edward
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (07): : 1461 - 1464
  • [45] Prevention of posterior capsule opacification using capsular tension in cataract surgery ring for zonular defects
    D'eliseo, D
    Pastena, B
    Longanesi, L
    Grisanti, F
    Negrini, V
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2003, 13 (02) : 151 - 154
  • [46] Impact of anterior capsule polishing on capsule opacification and capsule bend after age-related cataract surgery
    Huang, Feng
    Tong, Wentao
    Wang, Dandan
    Guan, Weichen
    Zhang, Zhewen
    Zhao, Yun-e
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (06): : 599 - 604
  • [47] Surgical prevention of posterior capsule opacification Part 1: Progress in eliminating this complication of cataract surgery
    Apple, DJ
    Peng, Q
    Visessook, N
    Werner, L
    Pandey, SK
    Escobar-Gomez, M
    Ram, J
    Whiteside, SB
    Schoderbeck, R
    Ready, EL
    Guindi, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (02): : 180 - 187
  • [48] Automated qualitative and quantitative assessment of posterior capsule opacification by Automated Quantification of After-Cataract II (AQUA II) system
    Kronschlaeger, Martin
    Siegl, Hannes
    Pinz, Axel
    Feichtenhofer, Christoph
    Buehl, Wolf
    Hirnschall, Nino
    Findl, Oliver
    BMC OPHTHALMOLOGY, 2019, 19 (1)
  • [49] Automated qualitative and quantitative assessment of posterior capsule opacification by Automated Quantification of After-Cataract II (AQUA II) system
    Martin Kronschläger
    Hannes Siegl
    Axel Pinz
    Christoph Feichtenhofer
    Wolf Buehl
    Nino Hirnschall
    Oliver Findl
    BMC Ophthalmology, 19
  • [50] Impact of anterior capsule polishing on anterior capsule opacification after cataract surgery: a randomized clinical trial
    Shah, S. K.
    Praveen, M. R.
    Kaul, A.
    Vasavada, A. R.
    Shah, G. D.
    Nihalani, B. R.
    EYE, 2009, 23 (08) : 1702 - 1706