Performance of the beam phase measurement system for LEDA

被引:0
|
作者
Power, JF [1 ]
Barr, D [1 ]
Gilpatrick, JD [1 ]
Kasemir, K [1 ]
Shurter, RB [1 ]
Stettler, M [1 ]
机构
[1] Univ Calif Los Alamos Natl Lab, Los Alamos, NM 87545 USA
来源
BEAM INSTRUMENTATION WORKSHOP 2000 | 2000年 / 546卷
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Low Energy Demonstration Accelerator (LEDA) facility diagnostics include beam phase measurements [1]. Beam signals at 350 MHz from capacitive probes are down-converted to 2 MHz for processing. The phase measurement process includes amplitude leveling, digital sampling of the I and Q vectors, DSP filtering and calibration, and serving of the data to the network. All hardware is fielded in the VXI format and controlled with a PC. Running under Windows NT, a LabVIEW(R) program controls the operation of the system and serves the data, via channel access, to the EPICS control system. The design and operational performance to date of the system is described.
引用
收藏
页码:535 / 540
页数:6
相关论文
共 50 条
  • [31] Beam Measurement System in NSRL
    Sun Baogen
    Journal of Systems Engineering and Electronics, 2000, (03) : 9 - 13
  • [32] AN AUTOMATED BEAM MEASUREMENT SYSTEM
    IRICK, SC
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 498 : 204 - 211
  • [33] Measurement of cyclotron beam phase space
    Pandit, VS
    Sarma, PR
    Bhandari, RK
    CYCLOTRONS AND THEIR APPLICATIONS 1998, 1999, : 189 - 192
  • [34] BEAM-PHASE MEASUREMENT STUDIES
    WHITE, WH
    DUELLI, B
    JONES, RJ
    NUCLEAR INSTRUMENTS & METHODS, 1962, 18 (NOV): : 601 - 605
  • [35] Initial operation of the LEDA beam-induced fluorescence diagnostic
    Kamperschroer, JH
    Gilpatrick, JD
    Gurd, PA
    Madsen, DW
    Martinez, DG
    O'Hara, JF
    Sage, J
    Schaefer, TL
    Shurter, RB
    Stettler, MW
    BEAM INSTRUMENTATION WORKSHOP 2000, 2000, 546 : 456 - 463
  • [36] Beam diameter measurement in focused ion beam system
    Zhang, Haibo
    Zhenkong Kexue yu Jishu Xuebao/Vacuum Science and Technology, 2000, 20 (05): : 319 - 321
  • [37] Analysis on the Effect of Phase Noise on the Performance of Satellite Communication and Measurement System
    Liu, Xuan
    Lu, Hongmin
    He, Yifeng
    Wu, Fulin
    Zhang, Chengxi
    Wang, Xiaoliang
    SYMMETRY-BASEL, 2023, 15 (11):
  • [38] Development of a fast scintillator based beam phase measurement system for compact superconducting cyclotrons
    Bhattacharjee, Tanushyam
    Dey, Malay Kanti
    Dhara, Partha
    Roy, Suvodeep
    Debnath, Jayanta
    Bhole, Rajendra Balakrishna
    Dutta, Atanu
    Pradhan, Jedidiah
    Pal, Sarbajit
    Pal, Gautam
    Roy, Amitava
    Chakrabarti, Alok
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (05):
  • [39] APT/LEDA RFQ vacuum pumping system
    Shen, S
    Kishiyama, K
    Parker, JM
    Wilson, NG
    Schrage, D
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 3625 - 3627
  • [40] Performance measurement system
    Kanji, GK