Radiofrequency saturation induced bias in aqueductal cerebrospinal fluid flow quantification obtained using two-dimensional cine phase contrast magnetic resonance imaging

被引:5
|
作者
Ragunathan, Sudarshan [1 ]
Pipe, James G. [1 ]
机构
[1] Barrow Neurol Inst, Imaging Res, 350 W Thomas Rd, Phoenix, AZ 85013 USA
关键词
phase contrast MRI; radio frequency saturation; cerebrospinal fluid flow; bias; NORMAL-PRESSURE HYDROCEPHALUS; STROKE VOLUME; CSF FLOW; INTRACRANIAL-PRESSURE; MR; PHYSIOLOGY; ACCURACY;
D O I
10.1002/mrm.26883
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo explore the extent of bias in cerebrospinal fluid flow estimates due to radiofrequency saturation, and its possible impact on the use of two-dimensional cine phase contrast magnetic resonance imaging in the diagnosis and characterization of normal pressure hydrocephalus in patients. Theory and MethodsTheoretical signal equations were generated to describe saturation dependence on velocity. An experimental set of phase contrast magnetic resonance imaging scans with two different flip angles was used to show bias in flow estimates in a flow phantom, and in six different healthy volunteers. The cerebral aqueduct was targeted as the flow region of interest. ResultsData from a constant flow phantom showed a spatial distribution of voxels with significant bias in flow at the periphery of the flow region. The velocity difference (bias) maps of the cerebral aqueduct correlated with the spatial velocity gradients around peak systole and peak diastole, and high correlation with temporal velocity gradients during transition between systole and diastole. The aqueductal stroke volume for =30 degrees were found to be significantly higher than for =10 degrees using a Wilcoxon signed rank test. ConclusionThis work shows the extent of bias in cerebrospinal fluid flow quantification due to radiofrequency saturation effects. This clinical relevance of this error was presented with respect to shunt responsiveness among normal pressure hydrocephalus patients. Magn Reson Med 79:2067-2076, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:2067 / 2076
页数:10
相关论文
共 50 条
  • [21] Pulsatile cerebrospinal fluid flow measurement using phase-contrast magnetic resonance imaging in patients with cervical myelopathy
    Shibuya, R
    Yonenobu, K
    Koizumi, T
    Kato, Y
    Mitta, M
    Yoshikawa, H
    SPINE, 2002, 27 (10) : 1087 - 1093
  • [22] Cerebrospinal Fluid Flow Dynamics in Multiple Sclerosis Patients through Phase Contrast Magnetic Resonance Imaging
    Lagana, Maria Marcella
    Chaudhary, Anamika
    Balagurunathan, Deepa
    Utriainen, David
    Kokeny, Paul
    Feng, Wei
    Cecconi, Pietro
    Hubbard, David
    Haacke, E. Mark
    CURRENT NEUROVASCULAR RESEARCH, 2014, 11 (04) : 349 - 358
  • [23] Semiautomatic analysis of phase contrast magnetic resonance imaging of cerebrospinal fluid flow through the aqueduct of Sylvius
    Florez, Yudy Natalia
    Moratal, David
    Forner, Juana
    Marti-Bonmati, Luis
    Arana, Estanislao
    Guajardo-Hernandez, Ulises
    Millet-Roig, Jose
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2006, 19 (02) : 78 - 87
  • [24] An approach to objective analysis of cerebrospinal fluid flow dynamics with phase-contrast magnetic resonance imaging
    Ucar, Murat
    Tokgoz, Nil
    ACTA NEUROCHIRURGICA, 2014, 156 (11) : 2207 - 2208
  • [25] Semiautomatic Analysis of Phase Contrast Magnetic Resonance Imaging of Cerebrospinal Fluid Flow through the Aqueduct of Sylvius
    Yudy Natalia Flórez
    David Moratal
    Juana Forner
    Luis Martí-Bonmatí
    Estanislao Arana
    Ulises Guajardo-Hernández
    José Millet-Roig
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2006, 19 : 78 - 87
  • [26] An approach to objective analysis of cerebrospinal fluid flow dynamics with phase-contrast magnetic resonance imaging
    Murat Ucar
    Nil Tokgoz
    Acta Neurochirurgica, 2014, 156 : 2207 - 2208
  • [27] Quantification of cerebral circulation and shunt volume in a tentorial dural arteriovenous fistula using two-dimensional phase-contrast magnetic resonance imaging
    Youn, Sung Won
    Kim, Ho Kyun
    Lee, Hui Joong
    Lee, Jongmin
    ACTA RADIOLOGICA OPEN, 2014, 3 (05):
  • [28] In Vivo Quantification of Helical Blood Flow in Human Aorta by Time-Resolved Three-Dimensional Cine Phase Contrast Magnetic Resonance Imaging
    Morbiducci, Umberto
    Ponzini, Raffaele
    Rizzo, Giovanna
    Cadioli, Marcello
    Esposito, Antonio
    De Cobelli, Francesco
    Del Maschio, Alessandro
    Montevecchi, Franco Maria
    Redaelli, Alberto
    ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (03) : 516 - 531
  • [29] In Vivo Quantification of Helical Blood Flow in Human Aorta by Time-Resolved Three-Dimensional Cine Phase Contrast Magnetic Resonance Imaging
    Umberto Morbiducci
    Raffaele Ponzini
    Giovanna Rizzo
    Marcello Cadioli
    Antonio Esposito
    Francesco De Cobelli
    Alessandro Del Maschio
    Franco Maria Montevecchi
    Alberto Redaelli
    Annals of Biomedical Engineering, 2009, 37
  • [30] Accelerated two-dimensional cine DENSE cardiovascular magnetic resonance using compressed sensing and parallel imaging
    Xiao Chen
    Yang Yang
    Xiaoying Cai
    Daniel A. Auger
    Craig H. Meyer
    Michael Salerno
    Frederick H. Epstein
    Journal of Cardiovascular Magnetic Resonance, 18