Radiofrequency saturation induced bias in aqueductal cerebrospinal fluid flow quantification obtained using two-dimensional cine phase contrast magnetic resonance imaging

被引:5
|
作者
Ragunathan, Sudarshan [1 ]
Pipe, James G. [1 ]
机构
[1] Barrow Neurol Inst, Imaging Res, 350 W Thomas Rd, Phoenix, AZ 85013 USA
关键词
phase contrast MRI; radio frequency saturation; cerebrospinal fluid flow; bias; NORMAL-PRESSURE HYDROCEPHALUS; STROKE VOLUME; CSF FLOW; INTRACRANIAL-PRESSURE; MR; PHYSIOLOGY; ACCURACY;
D O I
10.1002/mrm.26883
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo explore the extent of bias in cerebrospinal fluid flow estimates due to radiofrequency saturation, and its possible impact on the use of two-dimensional cine phase contrast magnetic resonance imaging in the diagnosis and characterization of normal pressure hydrocephalus in patients. Theory and MethodsTheoretical signal equations were generated to describe saturation dependence on velocity. An experimental set of phase contrast magnetic resonance imaging scans with two different flip angles was used to show bias in flow estimates in a flow phantom, and in six different healthy volunteers. The cerebral aqueduct was targeted as the flow region of interest. ResultsData from a constant flow phantom showed a spatial distribution of voxels with significant bias in flow at the periphery of the flow region. The velocity difference (bias) maps of the cerebral aqueduct correlated with the spatial velocity gradients around peak systole and peak diastole, and high correlation with temporal velocity gradients during transition between systole and diastole. The aqueductal stroke volume for =30 degrees were found to be significantly higher than for =10 degrees using a Wilcoxon signed rank test. ConclusionThis work shows the extent of bias in cerebrospinal fluid flow quantification due to radiofrequency saturation effects. This clinical relevance of this error was presented with respect to shunt responsiveness among normal pressure hydrocephalus patients. Magn Reson Med 79:2067-2076, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:2067 / 2076
页数:10
相关论文
共 50 条
  • [1] Analysis of aqueductal cerebrospinal fluid flow after endoscopic aqueductoplasty by using cine phase-contrast magnetic resonance imaging
    Schroeder, HWS
    Schweim, C
    Schweim, KH
    Gaab, MR
    JOURNAL OF NEUROSURGERY, 2000, 93 (02) : 237 - 244
  • [2] Evaluation of aqueductal cerebrospinal fluid flow dynamics with phase-contrast cine magnetic resonance imaging in normal pediatric cases
    Ozturk, Mehmet
    Sigirci, Ahmet
    Unlu, Serkan
    CLINICAL IMAGING, 2016, 40 (06) : 1286 - 1290
  • [3] Quantitative analysis of cerebrospinal fluid flow in patients with cervical spondylosis using cine phase-contrast magnetic resonance imaging
    Watabe, N
    Tominaga, T
    Shimizu, H
    Koshu, K
    Yoshimoto, T
    NEUROSURGERY, 1999, 44 (04) : 779 - 784
  • [4] Quantitative analysis of cerebrospinal fluid flow in patients with cervical spondylosis using cine phase-contrast magnetic resonance imaging - Comments
    Knopp, EA
    Cooper, PR
    NEUROSURGERY, 1999, 44 (04) : 784 - 784
  • [5] Quantification of cerebrospinal fluid flow in dogs by cardiac-gated phase-contrast magnetic resonance imaging
    Christen, Muriel A.
    Schweizer-Gorgas, Daniela
    Richter, Henning
    Joerger, Fabiola B.
    Dennler, Matthias
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (01) : 333 - 340
  • [6] Analysis of cerebrospinal fluid flow dynamics and morphology in Chiari I malformation with cine phase-contrast magnetic resonance imaging
    Wang, Cheng-Shi
    Wang, Xing
    Fu, Chu-Hua
    Wei, Lu-Qing
    Zhou, Dai-Quan
    Lin, Jiang-Kai
    ACTA NEUROCHIRURGICA, 2014, 156 (04) : 707 - 713
  • [7] Analysis of cerebrospinal fluid flow dynamics and morphology in Chiari I malformation with cine phase-contrast magnetic resonance imaging
    Cheng-Shi Wang
    Xing Wang
    Chu-Hua Fu
    Lu-Qing Wei
    Dai-Quan Zhou
    Jiang-Kai Lin
    Acta Neurochirurgica, 2014, 156 : 707 - 713
  • [8] Quantitative Evaluation of Normal Aqueductal Cerebrospinal Fluid Flow Using Phase-Contrast Cine MRI According to Age and Sex
    Oner, Zulal
    Kahraman, Aysegul Sagir
    Kose, Evren
    Oner, Serkan
    Kavakli, Ahmet
    Cay, Mahmut
    Ozbag, Davut
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2017, 300 (03): : 549 - 555
  • [9] CINE MAGNETIC-RESONANCE-IMAGING OF PULSATILE CEREBROSPINAL-FLUID FLOW USING CSPAMM
    WAYTE, SC
    REDPATH, TW
    BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (803): : 1088 - 1095
  • [10] Quantitative Analysis of Cerebrospinal Fluid Flow in Complex Regions by Using Phase Contrast Magnetic Resonance Imaging
    Florez, Natalia
    Bouzerar, Roger
    Moratal, David
    Meyer, Marc-Etienne
    Marti-Bonmati, Luis
    Baledent, Olivier
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2011, 21 (03) : 290 - 297