The DRE, the digital readout electronics for Athena X-IFU

被引:11
|
作者
Ravera, Laurent [1 ,2 ]
Cara, Christophe [3 ]
Teresa Ceballos, Maria [4 ]
Barcons, Xavier [4 ]
Barret, Didier [1 ,2 ]
Cledassou, Rodolphe [5 ]
Clenet, Antoine [1 ,2 ]
Cobo, Beatriz [4 ]
Doumayrou, Eric [3 ]
den Hartog, Roland H. [6 ]
van Leeuven, Bert-Joost [6 ]
van Loon, Dennis [6 ]
Mas-Hesse, Jose Miguel [7 ]
Pigot, Claude [3 ]
Pointecouteau, Etienne [1 ,2 ]
机构
[1] Univ Toulouse, UPS OMP, IRAP, Toulouse, France
[2] CNRS, IRAP, F-31028 Toulouse 4, France
[3] CEA SAP, F-91191 Gif Sur Yvette, France
[4] IFCA CSIC UC, Santander 39005, Spain
[5] CNES, F-31401 Toulouse 9, France
[6] SRON, NL-3584 CA Utrecht, Netherlands
[7] CAB CSIC INTA, Madrid 28691, Spain
关键词
Readout Electronics; Frequency Domain Multiplexing; Baseband Feedback; Optimal Filtering;
D O I
10.1117/12.2055750
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
We are developing the digital readout electronics (DRE) of the X-Ray Integral Field Unit (X-IFU), one of the two Athena focal plane instruments. This subsystem is made of two main parts: the DRE-DEMUX and the DRE-EP. With a frequency domain multiplexing (FDM) the DRE-DEMUX makes the readout of the 3 840 Transition Edge Sensors (TES) in 96 channels of 40 pixels each. It provides the AC signals to voltage-bias the TES, it demodulates the detector's data which are readout by a SQUID and low noise amplifiers and it linearizes the detection chain to increase its dynamic range. The feedback is computed with a specific technique, so called baseband feedback (BBFB) which ensures that the loop is stable even with long propagation and processing delays (i.e. a few mu s) and with high frequency AC-bias (up to 5 MHz). This processing is partly analogue (anti aliasing and reconstruction filters) but mostly digital. The digital firmware is simultaneously applied to all the pixels in digital integrated circuits. After the demultiplexing the interface between the DRE-DEMUX and the DRE-EP has to cope with a data rate of 61.44 Gbps to transmit the data of the individual pixels. Then, the DRE-EP detects the events and computes their energy and grade according to their spectral quality: low resolution, medium resolution and high resolution (i.e. if two consecutive events are too close the estimate of the energy is less accurate). This processing is done in LEON based processor boards. At its output the DRE-EP provides the control unit of the instrument with a list including for each event its time of arrival, its energy, its location on the focal plane and its grade.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] The Cryogenic AntiCoincidence Detector for ATHENA X-IFU: The Project Status
    Macculi, C.
    Argan, A.
    Brienza, D.
    D'Andrea, M.
    Lotti, S.
    Minervini, G.
    Piro, L.
    Biasotti, M.
    Barusso, L.
    Gatti, F.
    Rigano, M.
    Torrioli, G.
    Fiorini, M.
    Molendi, S.
    Uslenghi, M.
    Cavazzuti, E.
    Volpe, A.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2020, 199 (1-2) : 416 - 424
  • [42] The Cryogenic AntiCoincidence Detector for ATHENA X-IFU: a program overview
    Macculi, C.
    Argan, A.
    D'Andrea, M.
    Lotti, S.
    Laurenza, M.
    Piro, L.
    Biasotti, M.
    Corsini, D.
    Gatti, F.
    Torrioli, G.
    Fiorini, M.
    Molendi, S.
    Uslenghi, M.
    Mineo, T.
    Bulgarelli, A.
    Fioretti, V.
    Cavazzuti, E.
    SPACE TELESCOPES AND INSTRUMENTATION 2016: ULTRAVIOLET TO GAMMA RAY, 2016, 9905
  • [43] The Cryogenic AntiCoincidence Detector for ATHENA X-IFU: The Project Status
    C. Macculi
    A. Argan
    D. Brienza
    M. D’Andrea
    S. Lotti
    G. Minervini
    L. Piro
    M. Biasotti
    L. Ferrari Barusso
    F. Gatti
    M. Rigano
    G. Torrioli
    M. Fiorini
    S. Molendi
    M. Uslenghi
    E. Cavazzuti
    A. Volpe
    Journal of Low Temperature Physics, 2020, 199 : 416 - 424
  • [44] The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence Detector
    D'Andrea, M.
    Macculi, C.
    Torrioli, G.
    Argan, A.
    Brienza, D.
    Lotti, S.
    Minervini, G.
    Piro, L.
    Biasotti, M.
    Barusso, L. Ferrari
    Gatti, F.
    Rigano, M.
    Volpe, A.
    Battistelli, E. S.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2020, 199 (1-2) : 65 - 72
  • [45] The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence Detector
    M. D’Andrea
    C. Macculi
    G. Torrioli
    A. Argan
    D. Brienza
    S. Lotti
    G. Minervini
    L. Piro
    M. Biasotti
    L. Ferrari Barusso
    F. Gatti
    M. Rigano
    A. Volpe
    E. S. Battistelli
    Journal of Low Temperature Physics, 2020, 199 : 65 - 72
  • [46] Demonstrator model of the warm front-end electronics for the ATHENA mission's X-IFU instrument
    Gonzalez, Manuel
    Prele, Damien
    Chen, Si
    Ardellier, Florence
    Givaudan, Alain
    Courty, Bernard
    Blin, Sylvie
    Oger, Ronan
    Monier, Guy
    Colognes, Stephane
    Pailot, Damien
    Coleiro, Alexis
    Varniere, Peggy
    Goldwurm, Andrea
    SPACE TELESCOPES AND INSTRUMENTATION 2022: ULTRAVIOLET TO GAMMA RAY, 2022, 12181
  • [47] Estimates for the background of the ATHENA X-IFU instrument: the Cosmic Rays contribution
    Lotti, Simone
    Macculi, Claudio
    D'Andrea, Matteo
    Fioretti, Valentina
    Dondero, Paolo
    Mantero, Alfonso
    Minervini, Gabriele
    Argan, Andrea
    Piro, Luigi
    SPACE TELESCOPES AND INSTRUMENTATION 2018: ULTRAVIOLET TO GAMMA RAY, 2018, 10699
  • [48] The Cryo-Harness Technology for the Athena X-IFU Detection Chain
    Geoffray, H.
    Adams, J.
    Fossecave, H.
    Cucchetti, E.
    Bellouard, E.
    Peille, P.
    Daniel, C.
    Maisonnave, O.
    Guilhem, E.
    Jolly, A.
    Maussang, I.
    Jackon, B.
    Bandler, S.
    Doriese, B.
    Durkin, M.
    van der Kuur, J.
    van Leeuwen, B. J.
    Kiviranta, M.
    Prele, D.
    Ravera, L.
    Parot, Y.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2024, 215 (3-4) : 177 - 183
  • [49] Preliminary Mechanical Characterization of Thermal Filters for the X-IFU Instrument on Athena
    Barbera, Marco
    Lo Cicero, Ugo
    Sciortino, Luisa
    Parodi, Giancarlo
    D'Anca, Fabio
    Giglio, Paolo
    Bonura, Salvatore Ferruggia
    Nuzzo, Flavio
    Escobar, Antonio Jimenez
    Ciaravella, Angela
    Collura, Alfonso
    Varisco, Salvatore
    Samain, Valerie
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2018, 193 (5-6) : 793 - 798
  • [50] Preliminary Mechanical Characterization of Thermal Filters for the X-IFU Instrument on Athena
    Marco Barbera
    Ugo Lo Cicero
    Luisa Sciortino
    Giancarlo Parodi
    Fabio D’Anca
    Paolo Giglio
    Salvatore Ferruggia Bonura
    Flavio Nuzzo
    Antonio Jimenez Escobar
    Angela Ciaravella
    Alfonso Collura
    Salvatore Varisco
    Valerie Samain
    Journal of Low Temperature Physics, 2018, 193 : 793 - 798