Direct measurement of cochlear parameters for automatic calculation of the cochlear duct length

被引:27
|
作者
Khurayzi, Tawfiq [1 ]
Almuhawas, Fida [1 ]
Sanosi, Abdulrahman [1 ]
机构
[1] King Saud Univ KSU, Coll Med, King Abdullah Ear Specialist Ctr KAESC, Dept Otolaryngol, Riyadh 11451, Saudi Arabia
关键词
DEEP ELECTRODE INSERTION; MORPHOLOGY; CORTI; ORGAN; RECONSTRUCTION; VARIABILITY; SIZE;
D O I
10.5144/0256-4947.2020.218
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Cochlear morphology and cochlear duct length (CDL) play important roles in the selection of appropriate electrodes. Cochlear parameters such as diameter (A value) and width (B value) are used as inputs for calculating the CDL. Current measurements of these parameters are inefficient and time consuming. Recently developed otological planning software (OTOPLAN) allows surgeons to directly measure these parameters and then automatically calculate the CDL. OBJECTIVES: The primary objective was to validate this new software for measuring the cochlear parameters and CDL. The secondary aim was to investigate the correlation between each cochlear parameter with the calculated CDL. DESIGN: Retrospective. SETTINGS: Ear specialist hospital. PATIENTS AND METHODS: The measurement of cochlear diameter (A value) was chosen as the validation parameter. To do this, the A value was measured by a neurotologist on the new OTOPLAN planning software and was validated to the one measured on the currently used DICOM viewer. Upon the validation of the OTOPLAN software, the other two cochlear parameters, namely width (B value) and height (H value) were measured, and CDL was automatically calculated. Finally, the correlation of all parameters with the CDL was statistically analyzed. MAIN OUTCOME MEASURES: Validation of OTOPLAN and CDL estimation. SAMPLE SIZE: 88 ears. RESULTS: There was no significant difference between the A-value measured on the DICOM viewing software and that on the new planning software by the two independent neurotologists (P=.27). Both Aand B-values showed a high positive correlation to the CDL. However, the B-value showed a stronger correlation to the CDL than the A-value (r=0.63 for A, and r=0.96 for B). CONCLUSION: The direct measurement of cochlea parameters and automatic calculation of the CDL could improve the efficiency of clinical workflow and make otology surgeons more independent. Moreover, the cochlear width (B) has a strong correlation to the CDL. Thus, we suggest using the combination of A and B to accurately estimate the CDL rather than using only one. LIMITATIONS: Single center and small sample size.
引用
收藏
页码:212 / 218
页数:7
相关论文
共 50 条
  • [1] Automatic Cochlear Duct Length Estimation for Selection of Cochlear Implant Electrode Arrays
    Rivas, Alejandro
    Cakir, Ahmet
    Hunter, Jacob B.
    Labadie, Robert F.
    Zuniga, M. Geraldine
    Wanna, George B.
    Dawant, Benoit M.
    Noble, Jack H.
    OTOLOGY & NEUROTOLOGY, 2017, 38 (03) : 339 - 346
  • [2] Cochlear Implantation: Evaluation of Cochlear Duct Length (CDL)
    Mueller-Graff, Fraryz-Tassilo
    Rak, Kristen
    LARYNGO-RHINO-OTOLOGIE, 2022, 101 (05) : 428 - 441
  • [3] Surgical Experience in Pre-Operative Measurement of Cochlear Duct Length in Cochlear Implant Surgery
    Ngu, Chien Ying Vincent
    Tang, Ing Ping
    Narayanan, Prepageran
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2025, 77 (02) : 821 - 827
  • [4] On the accuracy of cochlear duct length measurement in computed tomographic images
    G. Jakob Lexow
    Marcel Kluge
    Nils-Claudius Gellrich
    Thomas Lenarz
    Omid Majdani
    Thomas S. Rau
    European Archives of Oto-Rhino-Laryngology, 2018, 275 : 1077 - 1085
  • [5] Dependence of Cochlear Duct Length Measurement on the Resolution of the Imaging Dataset
    Spahn, Bjoern
    Ilgen, Lukas
    Neun, Tilmann
    Mueller-Graff, Franz-Tassilo
    Schendzielorz, Philipp
    Hagen, Rudolf
    Althoff, Daniel
    Zabler, Simon
    Rak, Kristen
    OTOLOGY & NEUROTOLOGY, 2024, 45 (03) : e234 - e240
  • [6] On the accuracy of cochlear duct length measurement in computed tomographic images
    Lexow, G. Jakob
    Kluge, Marcel
    Gellrich, Nils-Claudius
    Lenarz, Thomas
    Majdani, Omid
    Rau, Thomas S.
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2018, 275 (05) : 1077 - 1085
  • [7] Use of MRI to determine cochlear duct length in patients undergoing cochlear implantation
    Nash, Robert
    Otero, Sofia
    Lavy, Jeremy
    COCHLEAR IMPLANTS INTERNATIONAL, 2019, 20 (02) : 57 - 61
  • [8] Enhancing cochlear duct length estimation by incorporating second-turn parameters
    Alahmadi, Asma
    Abdelsamad, Yassin
    Dhanasingh, Anandhan
    Almuhawas, Fida
    Alsanosi, Abdulrahman
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [9] Enhancing cochlear duct length estimation by incorporating second-turn parameters
    Asma Alahmadi
    Yassin Abdelsamad
    Anandhan Dhanasingh
    Fida Almuhawas
    Abdulrahman Alsanosi
    Scientific Reports, 13
  • [10] Radiographic Measurement of Cochlear Duct Length in an Indian Cadaveric Population-Importance of Custom Fit Cochlear Implant Electrodes
    Singh, Anup
    Kumar, Rajeev
    Manchanda, Smita
    Bhalla, Ashu Seith
    Sagar, Prem
    Irugu, David Victor Kumar
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2020, 24 (04) : E492 - E495