Radiographic Measurement of Cochlear Duct Length in an Indian Cadaveric Population-Importance of Custom Fit Cochlear Implant Electrodes

被引:4
|
作者
Singh, Anup [1 ]
Kumar, Rajeev [1 ]
Manchanda, Smita [2 ]
Bhalla, Ashu Seith [2 ]
Sagar, Prem [1 ]
Irugu, David Victor Kumar [1 ]
机构
[1] All India Inst Med Sci, Dept Otolaryngol & Head & Neck Surg, Room 4057,4th Floor,Teaching Block, New Delhi 110029, India
[2] All India Inst Med Sci, Dept Radiodiag, New Delhi, India
关键词
cochlear implantation; cochlear duct; tomography; adult; cadaver; AIDED 3-DIMENSIONAL RECONSTRUCTION; VARIABILITY; SIZE; CORTI; ORGAN;
D O I
10.1055/s-0040-1701272
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Introduction Successful cochlear implantation requires an appropriate insertion depth of the electrode, which depends on cochlear duct length CDL). The CDL can vary due to ethnic factors. Objective The objective of the current study was to determine the CDL in an Indian adult cadaveric population. Methods The present was a cadaveric study using the temporal bones obtained after permission of the Institutional Review Board. The temporal bones were subjected to high- resolution computed tomography (HRCT), and the double oblique reformatted CT images were reconstructed through the basal turn of the cochlea. The reformatted images were then viewed in the minimum-intensity projection (minIP) mode, and the 'A' value (the diameter of the basal turn of the cochlea) was calculated. The CDL was then measured using the formula CDL = 4.16A - 4 (Alexiades et al). The data analysis was performed using the Microsoft Excel software, version 2016. Results A total of 51 temporal bones were included for imaging analysis. The CDL varied from 27.6mm to 33.4mm, with a mean length of 30.7mm. There was no statistically significant difference between the two sides. Conclusion The CDL can be calculated with preoperative high-resolution CT, and can provide a roadmap for effective cochlear implant electrode insertion. The populationbased anatomical variability needs to be taken into account to offer the most efficient and least traumatic insertion of the electrode.
引用
收藏
页码:E492 / E495
页数:4
相关论文
共 2 条
  • [1] Surgical Experience in Pre-Operative Measurement of Cochlear Duct Length in Cochlear Implant Surgery
    Ngu, Chien Ying Vincent
    Tang, Ing Ping
    Narayanan, Prepageran
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2025, 77 (02) : 821 - 827
  • [2] Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection
    Thomas, Jan Peter
    Klein, Hannah
    Haubitz, Imme
    Dazert, Stefan
    Voelter, Christiane
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (04):