Novel Method for Estimating Utility Harmonic Impedance for a Direct-Drive Permanent Magnet Synchronous Generator Wind Farm

被引:0
|
作者
Zhou, Runze [1 ]
Ma, Xiaoyang [1 ]
Xu, Rui [1 ]
Xiao, Xianyong [1 ]
Zhao, Jinshuai [1 ]
机构
[1] Sichuan Univ, Coll Elect Engn, Chengdu 610065, Peoples R China
来源
IEEE ACCESS | 2022年 / 10卷
关键词
Harmonic analysis; Power harmonic filters; Impedance; Wind farms; Mathematical models; Estimation; Impedance measurement; D-PMSG wind farm; power quality; utility-side harmonic impedance wind-farm-side harmonic impedance; POWER-SYSTEM; IDENTIFICATION;
D O I
10.1109/ACCESS.2022.3141312
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Accurate estimation of the utility harmonic impedance is significant for harmonic control and responsibility division. Traditional methods of estimating the utility harmonic impedance are valid on the premise that the harmonic impedance on the wind-farm side is significantly greater than that on the utility side. However, with the installation of filters and reactive power compensation devices in wind farms, traditional estimation methods are no longer applicable. The accuracy of most existing estimation methods depends only on the accuracy of the model. This can cause large errors in the estimation of the utility harmonic impedance on a wind farm. To address this challenge, this paper proposes a method for estimating the utility harmonic impedance for a direct-drive permanent magnet synchronous generator wind farm based on a modified model with measured data. The proposed method uses the measured data to modify a model to obtain a more accurate estimation of the utility harmonic impedance. The results of the simulation and case study indicated that the traditional estimation methods have large errors when the background harmonic fluctuates significantly or the wind-farm-side harmonic impedance is smaller than the utility-side harmonic impedance. In contrast, the proposed method has a higher accuracy for the above scenarios.
引用
收藏
页码:25872 / 25882
页数:11
相关论文
共 50 条
  • [21] Operating capability as a PQ/PV node of a direct-drive wind turbine based on a permanent magnet synchronous generator
    Fernandez, L. M.
    Garcia, C. A.
    Jurado, F.
    RENEWABLE ENERGY, 2010, 35 (06) : 1308 - 1318
  • [22] Optimal direct-drive permanent magnet wind generator systems for different rated wind speeds
    Li, H.
    Chen, Z.
    2007 EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-10, 2007, : 3592 - 3601
  • [23] Modeling and Stability Analysis of a Direct-Drive Direct-Grid Slip-Synchronous Permanent-Magnet Wind Generator
    Potgieter, Johannes H. J.
    Kamper, Maarten J.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (03) : 1738 - 1747
  • [24] The Research on Direct Drive Permanent Magnet Synchronous Wind Generator Vector Control
    Zhang, Jiaying
    Zhang, Liping
    RENEWABLE AND SUSTAINABLE ENERGY II, PTS 1-4, 2012, 512-515 : 798 - 802
  • [25] Dimensioning Optimization of the Permanent Magnet Synchronous Generator for Direct Drive Wind Turbines
    Enriquez Santiago, Jesus Antonio
    Lastres Danguillecourt, Orlando
    Ibanez Duharte, Guillermo
    Conde Diaz, Jorge Evaristo
    Verde Anorve, Antonio
    Hernandez Escobedo, Quetzalcoatl
    Pantoja Enriquez, Joel
    Verea, Laura
    Hernandez Galvez, Geovanni
    Dorrego Portela, Rafael
    Perea-Moreno, Alberto-Jesus
    ENERGIES, 2021, 14 (21)
  • [26] Design optimization and comparison of large direct-drive permanent magnet wind generator systems
    Li, Hui
    Chen, Zhe
    2007 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-4, 2007, : 1161 - 1166
  • [27] Control of Parallel Multirectifiers for a Direct-Drive Permanent-Magnet Wind Power Generator
    Xu, Zhuang
    Li, Rui
    Xu, Dianguo
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2013, 49 (04) : 1687 - 1696
  • [28] Optimal Design of a Direct-Drive Permanent Magnet Synchronous Generator for Small-Scale Wind Energy Conversion Systems
    Abbasian, Mohammadali
    Isfahani, Arash Hassanpour
    JOURNAL OF MAGNETICS, 2011, 16 (04) : 379 - 385
  • [29] Dynamic equivalencing method for wind farms with permanent magnet direct-drive wind turbines
    Li, Li-Cheng
    Ye, Lin
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2013, 41 (01): : 204 - 210
  • [30] Parameter identification of direct-drive permanent magnet synchronous generator based on EDMPSO-EKF
    Xiao, Qianghui
    Liao, Kaixian
    Shi, Chuandong
    Zhang, Yang
    IET RENEWABLE POWER GENERATION, 2022, 16 (05) : 1073 - 1086