Adding in vivo quantitative 1H MR spectroscopy to improve diagnostic accuracy of breast MR imaging:: Preliminary results of observer performance study at 4.0 T

被引:91
|
作者
Meisamy, S
Bolan, PJ
Baker, EH
Pollema, MG
Le, CT
Kelcz, F
Lechner, MC
Luikens, BA
Carlson, RA
Brandt, KR
Amrami, KK
Nelson, MT
Everson, LI
Emory, TH
Tuttle, TM
Yee, D
Garwood, M
机构
[1] Res Med Sch, Ctr Magnet Resonance, Dept Radiol, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Radiol, Minneapolis, MN 55455 USA
[3] Univ Minnesota, Dept Biostat, Minneapolis, MN 55455 USA
[4] Univ Minnesota, Dept Surg, Minneapolis, MN 55455 USA
[5] Univ Minnesota, Dept Med, Minneapolis, MN 55455 USA
[6] Univ Minnesota, Ctr Canc, Minneapolis, MN 55455 USA
[7] Univ Wisconsin Hosp & Clin, Dept Radiol, Madison, WI 53792 USA
[8] Pk Nicollet Breast Ctr, Dept Radiol, Minneapolis, MN USA
[9] Suburban Radiol Consultants, Dept Radiol, Minneapolis, MN USA
[10] Mayo Clin, Dept Radiol, Rochester, MN USA
关键词
D O I
10.1148/radiol.2362040836
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine whether the addition of in vivo quantitative hydrogen 1 (H-1) magnetic resonance (MR) spectroscopy can improve the radiologist's diagnostic accuracy in interpreting breast MR images to distinguish benign from malignant lesions. MATERIALS AND METHODS: The study was approved by the institutional review board and, where appropriate, was compliant with the Health Insurance Portability and Accountability Act. All patients provided written informed consent. Fifty-five breast MR imaging cases-one lesion each in 55 patients aged 24-66 years with biopsy-confirmed findings-were retrospectively evaluated by four radiologists. Patients were examined with contrast material-enhanced fat-suppressed T1-weighted 4.0-T MR imaging. The concentration of total choline-containing compounds (tCho) was quantified by using single-voxel H-1 MR spectroscopy. For each case, the radiologists were asked to give the percentage probability of malignancy, the Breast Imaging and Reporting Data System category, and a recommendation for patient treatment. Two interpretations were performed for each case: The initial interpretation was based on the lesion's morphologic features and time-signal intensity curve, and the second interpretation was based on the lesion's morphologic features, time-signal intensity curve, and tCho concentration. Receiver operating characteristic (ROC), Wilcoxon signed rank, K statistic, and accuracy (based on the area under the ROC curve) analyses were performed. RESULTS: Of the 55 lesions evaluated, 35 were invasive carcinomas and 20 were benign. The addition of H-1 MR spectroscopy resulted in higher sensitivity, specificity, accuracy, and interobserver agreement for all four radiologists. More specifically, two of the four radiologists achieved a significant improvement in sensitivity (P = .03, P = .03), and all four radiologists achieved a significant improvement in accuracy (P = .01, P = .05, P = .009, P < .001). CONCLUSION: Current study results suggest that the addition of quantitative H-1 MR spectroscopy to the breast MR imaging examination may help to improve the radiologist's ability to distinguish benign from malignant breast lesions. (c) RSNA, 2005.
引用
收藏
页码:465 / 475
页数:11
相关论文
共 50 条
  • [21] In Vivo High-Resolution Localized 1H MR Spectroscopy in the Awake Rat Brain at 7 T
    Xu, Su
    Ji, Yadong
    Chen, Xi
    Yang, Yihong
    Gullapalli, Rao P.
    Masri, Radi
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (04) : 937 - 943
  • [22] Application of LCModel for quality control and quantitative in vivo 1H MR spectroscopy by short echo time STEAM sequence
    Hajek, Milan
    Burian, Martin
    Dezortova, Monika
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2000, 10 (01) : 6 - 17
  • [23] Short TE in vivo 1H MR spectroscopic imaging at 1.5 T:: acquisition and automated spectral analysis
    Soher, BJ
    Vermathen, P
    Schuff, N
    Wiedermann, D
    Meyerhoff, DJ
    Weiner, MW
    Maudsley, AA
    MAGNETIC RESONANCE IMAGING, 2000, 18 (09) : 1159 - 1165
  • [24] 1H MR Spectroscopy and Diffusion-Weighted Imaging of the Breast: Are They Useful Tools for Characterizing Breast Lesions Before Biopsy?
    Tozaki, Mitsuhiro
    Fukuma, Eisuke
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) : 840 - 849
  • [25] Editorial for "Multi-Parametric Ageing Study Across Adulthood in the Leg Through Quantitative MR Imaging, 1H Spectroscopy and 31P Spectroscopy at 3T"
    Krssak, Martin
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025, 61 (01) : 362 - 363
  • [26] 1H MR spectroscopy with external reference solution at 1.5 T for differentiating malignant and benign breast lesions: comparison using qualitative and quantitative approaches
    Mizukoshi, Waka
    Kozawa, Eito
    Inoue, Kaiji
    Saito, Naoko
    Nishi, Naoko
    Saeki, Toshiaki
    Kimura, Fumiko
    EUROPEAN RADIOLOGY, 2013, 23 (01) : 75 - 83
  • [27] 1H MR spectroscopy with external reference solution at 1.5 T for differentiating malignant and benign breast lesions: comparison using qualitative and quantitative approaches
    Waka Mizukoshi
    Eito Kozawa
    Kaiji Inoue
    Naoko Saito
    Naoko Nishi
    Toshiaki Saeki
    Fumiko Kimura
    European Radiology, 2013, 23 : 75 - 83
  • [28] Study of lipid metabolism by estimating the fat fraction in different breast tissues and in various breast tumor sub-types by in vivo 1H MR spectroscopy
    Agarwal, Khushbu
    Sharma, Uma
    Mathur, Sandeep
    Seenu, Vurthaluru
    Parshad, Rajinder
    Jagannathan, Naranamangalam R.
    MAGNETIC RESONANCE IMAGING, 2018, 49 : 116 - 122
  • [29] Predicting Pathological Response to Neoadjuvant Chemotherapy in Breast Cancer With Quantitative 1H MR Spectroscopy using the External Standard Method
    Tozaki, Mitsuhiro
    Sakamoto, Masaaki
    Oyama, Yu
    Maruyama, Katsuya
    Fukuma, Eisuke
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (04) : 895 - 902
  • [30] White matter and cerebral metabolite changes in children undergoing treatment for acute lymphoblastic leukemia:: Longitudinal study with MR imaging and 1H MR spectroscopy
    Chu, WCW
    Chik, KW
    Chan, YL
    Yeung, DKW
    Roebuck, DJ
    Howard, RG
    Li, CK
    Metreweli, C
    RADIOLOGY, 2003, 229 (03) : 659 - 669