Details of in-situ foam propagation exposed with magnetic resonance imaging

被引:12
|
作者
Wassmuth, FR [1 ]
Green, KA [1 ]
Randall, L [1 ]
机构
[1] Alberta Res Council, Petr Recovery Inst, Edmonton, AB T6H 5X2, Canada
关键词
D O I
10.2118/71300-PA
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper demonstrates the application of magnetic resonance imaging (MRI) to steady- and unsteady-state foam flow in porous media. Foam corefloods with and without surfactant preadsorption are discussed. The MRI instrument proved to be a useful tool in determining the in-situ saturation distributions during foam-flow experiments, with resolutions unmatched by other imaging techniques.
引用
收藏
页码:135 / 145
页数:11
相关论文
共 50 条
  • [31] Characteristics of ductal carcinoma in situ in magnetic resonance imaging
    Facius, Mirjam
    Renz, Diane M.
    Neubauer, Henning
    Boettcher, Joachim
    Gajda, Mieczyslaw
    Camara, Oumar
    Kaiser, Werner A.
    CLINICAL IMAGING, 2007, 31 (06) : 394 - 400
  • [32] VERSATILITY OF IN-SITU POLURETHANE FOAM.
    Colvin, B.G.
    Insulation Journal (Rickmansworth, England), 1987, 31 (09): : 26 - 28
  • [33] Brain magnetic resonance imaging of infants exposed prenatally to buprenorphine
    Kahila, H.
    Kivitie-Kallio, S.
    Halmesmaki, E.
    Valanne, L.
    Autti, T.
    ACTA RADIOLOGICA, 2007, 48 (02) : 228 - 231
  • [34] Magnetic resonance imaging of leukoencephalopathy in amnestic workers exposed to organotin
    Lee, Eunmi
    Park, Ji Eun
    Iida, Mayu
    Fujie, Tomoya
    Kaji, Toshiyuki
    Ichihara, Gaku
    Weon, Young Cheol
    Kim, Yangho
    NEUROTOXICOLOGY, 2016, 57 : 128 - 135
  • [35] Magnetic resonance imaging of human knee joint functionality under variable compressive in-situ loading and axis alignment
    Schad, Philipp
    Wollenweber, Maximilian
    Thuering, Johannes
    Schock, Justus
    Eschweiler, Joerg
    Palm, Giulia
    Radermacher, Klaus
    Eckstein, Felix
    Prescher, Andreas
    Kuhl, Christiane
    Truhn, Daniel
    Nebelung, Sven
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 110
  • [36] Magnetic resonance imaging versus mammography for diagnosing ductal carcinoma in-situ (DCIS) around invasive breast cancer
    Schrading, S.
    Kuhl, C. K.
    EJC SUPPLEMENTS, 2010, 8 (03): : 223 - 223
  • [37] Magnetic resonance imaging analysis on the in-situ mixing zone of CO 2 miscible displacement flows in porous media
    20142817932276
    1600, American Institute of Physics Inc. (115):
  • [38] Magnetic resonance imaging versus mammography for diagnosing ductal carcinoma in-situ (DCIS) around invasive breast cancer
    Schrading, S.
    Gnatzy, A.
    Wardelmann, E.
    Braun, M.
    Schild, H.
    Kuhl, C. K.
    JOURNAL OF CLINICAL ONCOLOGY, 2008, 26 (15)
  • [39] IN-SITU MAGNETIZING EXPERIMENTS USING COHERENT MAGNETIC IMAGING IN TEM
    MCVITIE, S
    CHAPMAN, JN
    ZHOU, L
    HEYDERMAN, LJ
    NICHOLSON, WAP
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1995, 148 (1-2) : 232 - 236
  • [40] 3-DIMENSIONAL MAGNETIC-RESONANCE-IMAGING OF A LIQUID FOAM
    PRAUSE, BA
    GLAZIER, JA
    GRAVINA, SJ
    MONTEMAGNO, CD
    JOURNAL OF PHYSICS-CONDENSED MATTER, 1995, 7 (40) : L511 - L516