Application of Zero-Sequence Filter on Transformer Differential Protection

被引:0
|
作者
Cimadevilla, Roberto
机构
关键词
Zero-sequence filter; phantom tertiary; three-legged transformer; differential unit; directional comparison unit; harmonic blocking;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Delta-Wye transformer connections create discontinuities in the zero-sequence network as the zero-sequence current can flow at one side of the transformer without flowing at the other side. This effect generates a zero-sequence differential current that can make the differential unit trip. Traditional solutions applied to remove the zero sequence differential current where based on delta connected CTs. Zero-sequence filters in digital relays are software implemented. In many digital relays the zero sequence filter can be enabled or disabled. On the other hand, some relays can remove the zero-sequence current calculated from the phase currents or from the ground currents (currents measured in the neutral grounding). This paper reviews the transformer configurations that require the enabling of the zero-sequence filter by taking into account not only the connection group but also the construction of the magnetic core (this aspect is not always considered), explaining in detail the phantom or virtual tertiary effect of three-legged wye-wye transformers. Real false trips due to this effect are included. The paper also explains the differences between both methods used for the zero-sequence current calculation (the one based on the phase currents and the one based on the ground current). The influence on the differential unit, harmonic restraint and common external fault detectors is analyzed. The first method can lead to a reduction of the differential current and to an erroneous phase selection during an internal fault. However, "2 out of 3" logics both for harmonic blocking and for a phase directional comparison unit can be implemented increasing the stability. The second method provides very good sensibility and phase selection but does not allow the implementation of the "2 out of 3" logics reducing the stability. Cases based on real events and RTDS simulations are reviewed.
引用
收藏
页码:785 / 814
页数:30
相关论文
共 50 条
  • [41] Harmonics filtering method used for generator longitudinal zero-sequence voltage protection
    Zhejiang University, Hangzhou 310027, China
    Dianli Xitong Zidonghue, 2008, 14 (68-72):
  • [42] Zero-sequence harmonics current minimization using zero-blocking transformer and shunt LC passive filters
    Syafrudin, M
    Hadzer, CM
    Sutanto, J
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 116 - 120
  • [43] Zero-sequence current differential phase selection based on three-sequence differential currents similar principle
    Liu, Huanzhang
    Wang, Xingguo
    Li, Ming
    Zhou, Zexin
    Du, Dingxiang
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2013, 37 (16): : 92 - 95
  • [44] A Novel Technique for Reducing Leakage Current by Application of Zero-Sequence Voltage
    Ayano, Hideki
    Murakami, Kouhei
    Matsui, Yoshihiro
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (04) : 3094 - 3100
  • [45] Zero-sequence harmonics current minimization using zero-blocking reactor and Zig-Zag transformer
    Song, Qipeng
    Yin, Zhongdong
    Xue, Jinhui
    Zhou, Lixia
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 1758 - 1764
  • [46] A Novel Technique for Reducing Leakage Current by Application of Zero-Sequence Voltage
    Ayano, Hideki
    Murakami, Kouhei
    Matsui, Yoshihiro
    2014 INTERNATIONAL POWER ELECTRONICS CONFERENCE (IPEC-HIROSHIMA 2014 - ECCE-ASIA), 2014, : 2385 - 2391
  • [47] ZERO-SEQUENCE REPRESENTATION OF OVERHEAD LINES
    NAHMAN, JM
    ARCHIV FUR ELEKTROTECHNIK, 1982, 65 (4-5): : 209 - 217
  • [48] Zero-Mode Inrush Current Characteristics and Zero-Sequence Protection Countermeasure Under Sympathetic Interaction
    Pan, Yuanlin
    Yin, Xianggen
    Yin, Xin
    Lai, Jinmu
    Xu, Cheng
    Han, Ke
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (05) : 3669 - 3678
  • [49] Coordination of Superconductive Fault Current Limiters With Zero-Sequence Current Protection of Transmission Lines
    Li, Bin
    Li, Chao
    Guo, Fengrui
    Xin, Ying
    Wang, Chuncheng
    Pang, Xueyue
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2014, 24 (05)
  • [50] Regionalized Zero-sequence Protection for Low-resistance Grounded System with Distributed Generator
    Qiao Y.
    Wu H.
    Wu T.
    Li X.
    Hou X.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2023, 47 (10): : 186 - 194