Mass transfer and chemical reaction in hollow-fiber membrane reactors

被引:9
|
作者
Li, K [1 ]
Tan, XY
机构
[1] Univ Bath, Dept Chem Engn, Bath BA2 7AY, Avon, England
[2] Shandong Inst Technol, Dept Chem Engn, Shandong 255012, Peoples R China
关键词
D O I
10.1002/aic.690470219
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Theoretical models developed describe hollow-fiber memebrane reactors (modules), in which membrane functions as an efficient reactant distributor and the chemical reaction takes place either in the hollow-fiber lumen or in the shell side. Effects of various design and operating parameters, and physical properties on the performance of the reactors were studied. Simulation results indicated that the axial dispersion has to be considered when the chemical reaction takes place in the shell side. It, however, may be neglected when Pe > 40. Theoretical results further revealed that the mass-transfer direction of the reactant through the membrane might be reversed when the chemical reaction in the liquid is extremely fast. Experimental data in the literature obtained from water-treatment processes agreed satisfactorily with the theoretical solutions. Based on the developed solution method, the reaction kinetic parameters can also be obtained conveniently.
引用
收藏
页码:427 / 435
页数:9
相关论文
共 50 条
  • [41] IN-STREAM HOLLOW-FIBER MEMBRANE AERATION
    Weiss, Peter T.
    Gulliver, John S.
    Semmens, Michael J.
    Journal of Hydraulic Engineering, 1998, 124 (06): : 579 - 588
  • [42] MORPHOLOGY AND PERFORMANCE OF POLYSULFONE HOLLOW-FIBER MEMBRANE
    LEE, SH
    KIM, JJ
    KIM, SS
    KIM, UY
    JOURNAL OF APPLIED POLYMER SCIENCE, 1993, 49 (03) : 539 - 548
  • [43] HOLLOW-FIBER MODULES MADE WITH HOLLOW-FIBER FABRIC
    WICKRAMASINGHE, SR
    SEMMENS, MJ
    CUSSLER, EL
    JOURNAL OF MEMBRANE SCIENCE, 1993, 84 (1-2) : 1 - 14
  • [44] In-stream hollow-fiber membrane aeration
    Dept. of Civ. Engrg., Univ. of Hartford, West Hartford, CT 06117, United States
    不详
    不详
    J. Hydraul. Eng., 6 (579-588):
  • [45] Modeling the mass transfer in solvent-extraction processes with hollow-fiber membranes
    Bocquet, S
    Torres, A
    Sanchez, J
    Rios, GM
    Romero, J
    AICHE JOURNAL, 2005, 51 (04) : 1067 - 1079
  • [46] Analytical solution to mass transfer in laminar flow in hollow fiber with heterogeneous chemical reaction
    Loney, NW
    CHEMICAL ENGINEERING SCIENCE, 1996, 51 (16) : 3995 - 3999
  • [48] Mass transfer characteristics of a continuously operated hollow-fiber membrane contactor and stripper unit for CO2 capture
    Nieminen, H.
    Jarvinen, L.
    Ruuskanen, V.
    Laari, A.
    Koiranen, T.
    Ahola, J.
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2020, 98
  • [49] Heat and mass transfer in hollow-fiber modules for direct contact membrane distillation: Integral transforms solution and parametric analysis
    Lisboa, Kleber Marques
    Brito de Souza, Jose Roberto
    Naveira-Cotta, Carolina Palma
    Cotta, Renato Machado
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2019, 109
  • [50] Oxygen Transfer Model for a Flow-Through Hollow-Fiber Membrane Biofilm Reactor
    Gilmore, Kevin R.
    Little, John C.
    Smets, Barth F.
    Love, Nancy G.
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2009, 135 (09) : 806 - 814