摘要
We report on the development of high-sensitivity and compact Compton imaging systems built of large and position-sensitive Si(Li) and HPGe detectors. The primary goal of this effort is to provide improved capabilities in the passive detection of nuclear materials for homeland security. Our detectors are implemented in double-sided strip configuration, which-along with digital signal processing-provides energies and three-dimensional position information of individual gamma-ray interactions. gamma-Ray tracking algorithms then determine the scattering sequence of the y-ray, which in turn allows us-employing the Compton scattering formula-to reconstruct a cone of possible incident angles and ultimately an image. This Compton imaging concept enables large-field-of-view gamma-ray imaging without the use of a heavy collimator or aperture. The intrinsically high-energy resolution of the detectors used, the excellent position resolution we have demonstrated, both combined with the high efficiency of large-volume detectors is the basis for high Compton imaging sensitivity. These capabilities are being developed to identify and localize potential threat sources and to potentially increase the sensitivity in detecting weak sources out of the midst of natural, medical, or commercial sources. y-ray imaging provides a new degree of freedom to distinguish between spatial and temporal background fluctuations and compact threat sources. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:363 / 366
页数:4
相关论文
共 50 条
  • [31] FAST TIMING POSITION-SENSITIVE DETECTORS
    KLEIN, C
    TROTSCHER, J
    WOLLNIK, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 335 (1-2): : 146 - 147
  • [32] Noise analysis for position-sensitive detectors
    Narayanan, C
    Buckman, AB
    Busch-Vishniac, I
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1997, 46 (05) : 1137 - 1144
  • [33] POSITION-SENSITIVE DETECTORS AND WEISSENBERG DIFFRACTOMETERS
    PRINCE, E
    SANTORO, A
    ACTA CRYSTALLOGRAPHICA SECTION A, 1975, 31 : S234 - S234
  • [34] EPITAXIAL SILICON POSITION-SENSITIVE DETECTORS
    SHIRAISHI, F
    KIM, C
    KIM, H
    KIKUCHI, K
    HUSIMI, K
    OHKAWA, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) : 554 - 557
  • [35] High-Sensitivity Seawater Refraction Index Optical Measurement Sensor Based on a Position-Sensitive Detector
    Zhou, Guanlong
    Li, Liyan
    Zhou, Yan
    Chen, Xinyu
    SENSORS, 2024, 24 (07)
  • [36] POSITION - SENSITIVE DETECTORS Graphene/silicon position-sensitive detector has enhanced sensitivity, IR capability
    Wallace, John
    LASER FOCUS WORLD, 2018, 54 (03): : 15 - 17
  • [37] DEVELOPMENT OF POSITION-SENSITIVE SCINTILLATION DETECTORS
    ROGERS, EH
    WHITESID.H
    ARENS, JF
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (04): : 455 - 455
  • [38] DIGITAL PROCESSOR FOR POSITION-SENSITIVE DETECTORS
    FISCHER, BE
    NUCLEAR INSTRUMENTS & METHODS, 1977, 141 (01): : 173 - 181
  • [39] Position-sensitive vacuum photon detectors
    Gys, Thierry
    Joram, Christian
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 970
  • [40] Positioning resolution of the position-sensitive detectors in high background illumination
    Makynen, A
    Kostamovaara, J
    Myllyla, R
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1996, 45 (01) : 324 - 326