The influence of aberrations in third harmonic generation microscopy

被引:6
|
作者
Thayil, Anisha [1 ]
Jesacher, Alexander [1 ]
Wilson, Tony [1 ]
Booth, Martin J. [1 ]
机构
[1] Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
基金
奥地利科学基金会; 英国生物技术与生命科学研究理事会; 英国工程与自然科学研究理事会;
关键词
aberrations; adaptive optics; harmonic generation; microscopy; 3RD-HARMONIC GENERATION; LASER; EMBRYOS;
D O I
10.1088/2040-8978/12/8/084009
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present an analysis of the effects of aberrations in third harmonic generation (THG) microscopy by considering different specimen geometries. Numerical simulations show the general trend that signal intensity and resolution are reduced as aberrations increase in amplitude. It is also shown that there are certain combinations of specimen structure and focusing position for which the presence of aberrations results in an increase in the image intensity. This occurs, for example, when there are several interfaces near the focal volume. The axial spreading of the excitation focal volume increases the characteristic coherence length for THG signal build-up, resulting in a significant contribution to the image brightness from axial planes near the focal plane. These results have important consequences for the interpretation of THG microscope images and for image based aberration correction in adaptive optics THG microscopy.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Third-harmonic generation microscopy in highly scattering media:: comment
    Schins, JM
    Müller, M
    APPLIED OPTICS, 2002, 41 (10) : 1995 - 1995
  • [42] Virtual optical biopsy of human adipocytes with third harmonic generation microscopy
    Tsai, Cheng-Kun
    Wang, Tzung-Dau
    Lin, Jong-Wei
    Hsu, Ron-Bin
    Guo, Lun-Zhang
    Chen, San-Tai
    Liu, Tzu-Ming
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (01): : 178 - 186
  • [43] Third-harmonic generation microscopy with Bessel beams: a numerical study
    Olivier, Nicolas
    Debarre, Delphine
    Mahou, Pierre
    Beaurepaire, Emmanuel
    OPTICS EXPRESS, 2012, 20 (22): : 24886 - 24902
  • [44] Signal epidetection in third-harmonic generation microscopy of turbid media
    Debarre, Delphine
    Olivier, Nicolas
    Beaurepaire, Emmanuel
    OPTICS EXPRESS, 2007, 15 (14): : 8913 - 8924
  • [45] Influence of third-order nonlinear and phase variations on third harmonic generation
    Zhao, Huajun
    Cheng, Zhengfu
    Shi, Dongping
    OPTIK, 2008, 119 (04): : 161 - 166
  • [46] Axial resolution enhancement of third harmonic generation microscopy by harmonic focal point axial modulation
    Dashtabi, Mahdi Mozdoor
    Arabanian, Atoosa Sadat
    Massudi, Reza
    APPLIED PHYSICS LETTERS, 2017, 110 (07)
  • [47] Simultaneous four-photon luminescence, third-harmonic generation, and second-harmonic generation microscopy of GaN
    Chu, SW
    Chan, MC
    Tai, SP
    Keller, S
    DenBaars, SP
    Sun, CK
    OPTICS LETTERS, 2005, 30 (18) : 2463 - 2465
  • [48] Harmonic Generation Microscopy
    Chen, Szu-Yu
    Sun, Chi-Kuang
    CURRENT TRENDS OF OPTICS AND PHOTONICS, 2015, 129 : 517 - 536
  • [49] Third-harmonic generation microscopy in highly scattering media: reply to comment
    Saloma, C
    APPLIED OPTICS, 2002, 41 (10) : 1996 - 1997
  • [50] Imaging of Corneal Incisions by Second- and Third-Harmonic Generation Microscopy
    Jay, L.
    Dion, C.
    Brocas, A.
    Singh, K.
    Kieffer, J. -C.
    Brunette, I.
    Ozaki, T.
    2010 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO) AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (QELS), 2010,