The dose discrepancies between Monte Carlo calculations and measurements in the build-up region for high-energy photon beams

被引:0
|
作者
Fu, Y [1 ]
Li, S [1 ]
Ayyangar, K [1 ]
Enke, C [1 ]
机构
[1] Univ Nebraska, Med Ctr, Omaha, NE 68182 USA
关键词
D O I
10.1118/1.1998007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To study the dose discrepancies between Monte Carlo calculations and measurements in the build‐up region for high energy photon beams. There are previous studies which show that neutrons present in a high‐energy photon beam are unlikely to be responsible for the reported discrepancies (Ding et al 2002, Hartmann Siantar et al 2001) in the build‐up region for large fields. It is necessary to figure out if the discrepancy could be a result of flaws in the Monte Carlo simulation or uncertainties in the measured data in the build‐up region. Method and Materials: The EGSnrc Monte Carlo code, BEAMnrc, has been used to simulate dose distributions produced by 23MV photon beams from a Siemens Primus Linac for 5×5cm2, 10×10 cm2, 15×15 cm2, 25×25 cm2 and 40×40 cm2 field sizes. The simulation of the accelerator was accomplished in two stages. The stored phase space file from the first stage was used repeatedly for the second stage as source data. The corresponding depth‐dose curves in the build‐up region for the above field sizes were measured in the solid water by a plane parallel chamber and in water by a cylindrical chamber. Results: Comparisons between the calculations and measurements reveal the dose discrepancies in the build‐up region fields increase with increasing field size. However, the differences between the measurements by different measurement detectors are far less than those between the calculations and measurements. Conclusion: The discrepancy is caused by the simulation itself. Just as Hartmann Siantar C L et al (2001) hypothesized, it may be caused by a source of electrons in the accelerator head that was not fully accounted for in the treatment head simulation. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2014 / 2014
页数:1
相关论文
共 50 条
  • [21] DOSE CALCULATIONS FOR HIGH-ENERGY ELECTRON AND PHOTON BEAMS
    CUNNINGHAM, JR
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1989, 13 (03) : 241 - 250
  • [22] Comparison of Different Build-Up Factor Calculations with Monte Carlo Simulations
    Bednar, David
    Listjak, Martin
    Slimak, Andrej
    Necas, Vladimir
    APPLIED PHYSICS OF CONDENSED MATTER (APCOM 2019), 2019, 2131
  • [23] Surface and build-up region dose characteristics for high energy photons
    Bilge, Hatice
    Kucucuk, Halil
    Yondem, Serpil
    Cakir, Aydin
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2006, 21 (04): : 168 - 173
  • [24] Dose calculation accuracy in the build-up region of flattening filter-free photon beams
    De Puysseleyr, A.
    Lechner, W.
    Georg, D.
    De Wagter, C.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S71 - S72
  • [25] ADVANCED KERNEL METHODS VERSUS MONTE CARLO BASED DOSE CALCULATIONS FOR HIGH ENERGY PHOTON BEAMS
    Georg, D.
    Winkler, P.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S59 - S59
  • [26] VARIATION IN POSITION OF CENTRAL AXIS MAXIMUM BUILD-UP POINT WITH FIELD SIZE FOR HIGH-ENERGY PHOTON BEAMS
    ALMOND, P
    VANROOSE.E
    BROWNE, R
    MILCAMP, J
    WILLIAMS, CB
    BRITISH JOURNAL OF RADIOLOGY, 1970, 43 (516): : 911 - &
  • [27] Accuracy of Monte Carlo Dose Calculations with Kilovoltage Photon Beams
    Bazalova, M.
    Graves, E.
    MEDICAL PHYSICS, 2011, 38 (06) : 3871 - +
  • [28] DOSE CONVERSION AND WALL CORRECTION FACTORS FOR FRICKE DOSIMETRY IN HIGH-ENERGY PHOTON BEAMS - ANALYTICAL MODEL AND MONTE-CARLO CALCULATIONS
    MA, CM
    NAHUM, AE
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (01): : 93 - 114
  • [29] Build-Up Region Dosimetry of Megavoltage Photon Beams for Breast Radiotherapy
    Ahmad, M.
    Deng, J.
    Lincoln, H.
    Nguyen, K. T.
    Griffin, M. E.
    Chen, Z.
    Nath, S.
    Moran, M.
    Husain, Z.
    Nath, R.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [30] The Perturbation Correction Factors for Plane-Parallel Ion Chamber Dose Measurements in the Build-Up Region of Megavoltage Photon Beams
    Yoshiyama, F.
    Araki, F.
    Ono, T.
    MEDICAL PHYSICS, 2010, 37 (06)