Response of wind-excited benchmark building installed with dampers

被引:16
|
作者
Patil, V. B. [1 ]
Jangid, R. S. [1 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Bombay 400076, Maharashtra, India
来源
关键词
SEMIACTIVE FRICTION DAMPERS; SEISMIC STRUCTURES; VISCOUS DAMPER; MODAL CONTROL;
D O I
10.1002/tal.523
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The response of the benchmark building is investigated under across-wind loads. The governing equations of motion are solved by employing state space theory. Generally, the dampers are connected to successive floors of a building (Type-I arrangement). As the relative velocity and inter-storey drift between the alternate floors would be larger, the performance of dampers is studied by connecting them to alternate stories with two innovative (Type-II and Type-III) arrangements, and the comparison of response is made with that of the conventional (Type-I) arrangement. Optimization of location and number of dampers is also carried out with the help of a controllability index, which is obtained with the help of root-mean-square value of the inter-storey drift. Further, a parametric study of semi-active variable friction dampers and linear viscous dampers by varying gain multiplier and damping ratio, respectively, is carried out. From the numerical study, it is observed that Type-II and Type-III arrangements are found to be quite effective in reducing the response quantities. It is also found that a considerable amount of economy is achieved by optimization of location of dampers. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:497 / 514
页数:18
相关论文
共 50 条
  • [31] DYNAMIC RESPONSE AND RELIABILITY ANALYSIS OF WIND-EXCITED WIND TURBINE SYSTEMS
    He, Guang-Ling
    Li, Jie
    ISISS '2009: INNOVATION & SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2, 2009, : 1518 - 1525
  • [32] Optimal placement of passive dampers on seismic and wind-excited buildings using combinatorial optimization
    Dept. of Civ. and Environ. Eng., University of California, Irvine, CA 92697, United States
    J Intell Mater Syst Struct, 12 (997-1014):
  • [33] Optimal placement of passive dampers on seismic and wind-excited buildings using combinatorial optimization
    Agrawal, AK
    Yang, JN
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 1999, 10 (12) : 997 - 1014
  • [34] Extreme value of wind-excited response considering influence of bandwidth
    Huang, Guoqing
    Chen, Xinzhong
    Li, Mingshui
    Peng, Liuliu
    JOURNAL OF MODERN TRANSPORTATION, 2013, 21 (02): : 125 - 134
  • [35] Evaluation of peak resultant response for wind-excited tall buildings
    Chen, Xinzhong
    Huang, Guoqing
    ENGINEERING STRUCTURES, 2009, 31 (04) : 858 - 868
  • [36] Extreme value of wind-excited response considering influence of bandwidth
    Guoqing Huang
    Xinzhong Chen
    Mingshui Li
    Liuliu Peng
    Journal of Modern Transportation, 2013, (02) : 125 - 134
  • [37] Hybrid simulation of thunderstorm outflows and wind-excited response of structures
    Solari, Giovanni
    Rainisio, Davide
    De Gaetano, Patrizia
    MECCANICA, 2017, 52 (13) : 3197 - 3220
  • [38] Stochastic response estimation of wind-excited structures with uncertain parameters
    Jin, WL
    Song, ZG
    ADVANCES IN STOCHASTIC STRUCTURAL DYNAMICS, 2003, : 247 - 253
  • [39] Hybrid simulation of thunderstorm outflows and wind-excited response of structures
    Giovanni Solari
    Davide Rainisio
    Patrizia De Gaetano
    Meccanica, 2017, 52 : 3197 - 3220
  • [40] Semiactive Wind Response Control of 76-story Benchmark Building with Smart Piezoelectric Friction Dampers
    Dong, Ping
    Fan, Jian
    ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 2196 - 2201