The response of the benchmark building is investigated under across-wind loads. The governing equations of motion are solved by employing state space theory. Generally, the dampers are connected to successive floors of a building (Type-I arrangement). As the relative velocity and inter-storey drift between the alternate floors would be larger, the performance of dampers is studied by connecting them to alternate stories with two innovative (Type-II and Type-III) arrangements, and the comparison of response is made with that of the conventional (Type-I) arrangement. Optimization of location and number of dampers is also carried out with the help of a controllability index, which is obtained with the help of root-mean-square value of the inter-storey drift. Further, a parametric study of semi-active variable friction dampers and linear viscous dampers by varying gain multiplier and damping ratio, respectively, is carried out. From the numerical study, it is observed that Type-II and Type-III arrangements are found to be quite effective in reducing the response quantities. It is also found that a considerable amount of economy is achieved by optimization of location of dampers. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:497 / 514
页数:18
相关论文
共 50 条
  • [1] Optimization of MR Dampers for Wind-Excited Benchmark Tall Building
    Suthar, Sameer J.
    Patil, Veeranagouda B.
    Jangid, Radhey Shyam
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2022, 27 (04)
  • [2] Wind tunnel tests for wind-excited benchmark building
    Samali, B
    Kwok, KCS
    Wood, GS
    Yang, JN
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 2004, 130 (04): : 447 - 450
  • [3] Model predictive control of wind-excited building: Benchmark study
    Mei, G
    Kareem, A
    Kantor, JC
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 2004, 130 (04): : 459 - 465
  • [4] Dynamic Response Control of a Wind-Excited Tall Building with Distributed Multiple Tuned Mass Dampers
    Elias, Said
    Matsagar, Vasant
    Datta, T. K.
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2019, 19 (06)
  • [5] A benchmark problem for response control of wind-excited tall buildings
    Yang, JN
    Agrawal, AK
    Samali, B
    Wu, JC
    PROCEEDINGS OF IMAC-XIX: A CONFERENCE ON STRUCTURAL DYNAMICS, VOLS 1 AND 2, 2001, 4359 : 151 - 157
  • [6] OPTIMUM MULTIPLE TUNED MASS DAMPERS FOR THE WIND EXCITED BENCHMARK BUILDING
    Patil, Veeranagouda B.
    Jangid, Radhey Shyam
    JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2011, 17 (04) : 540 - 557
  • [7] Analysis of a Benchmark Building Installed with Tuned Mass Dampers under Wind and Earthquake Loads
    Elias, S.
    Rupakhety, R.
    Olafsson, S.
    SHOCK AND VIBRATION, 2019, 2019
  • [8] Seismic analysis of benchmark building installed with friction dampers
    Raut, Bhiva R.
    Jangid, R.S.
    IES Journal Part A: Civil and Structural Engineering, 2014, 7 (01): : 20 - 37
  • [9] Composite mass dampers for vibration control of wind-excited towers
    Yan, N
    Wang, CM
    Balendra, T
    JOURNAL OF SOUND AND VIBRATION, 1998, 213 (02) : 301 - 316
  • [10] Dynamic analysis of wind-excited truss tower with friction dampers
    Qu, WL
    Chen, ZH
    Xu, YL
    COMPUTERS & STRUCTURES, 2001, 79 (32) : 2817 - 2831