A Comparative Study of Video Signals for Non-contact Heart Rate Measurement

被引:0
|
作者
Lueangwattana, Chanya [1 ]
Kondo, Toshiaki [1 ]
Haneishi, Hideaki [2 ]
机构
[1] Thammasat Univ, Sirindhorn Int Inst Technol, Sch Informat Comp & Commun Technol, Pathum Thani, Thailand
[2] Chiba Univ, Ctr Frontier Med Engn, Chiba 2638522, Japan
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper describes a comparative study of the various color signals for non-contact heart rate (HR) measurement on a video sequence. The color signals include red, green, blue, hue, the principal components of the red, green, and blue signals from video data. Experimental results prove that hue and the 3rd principal component are the most effective signals for the HR measurement. Experimental results also show that the two signals behave differently to different lighting conditions. Thus, we have integrated the two signals and achieved an improved performance than those based on a single color signal.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Non-contact Video-based Pulse Rate Measurement on a Mobile Service Robot
    Stricker, Ronny
    Mueller, Steffen
    Gross, Horst-Michael
    2014 23RD IEEE INTERNATIONAL SYMPOSIUM ON ROBOT AND HUMAN INTERACTIVE COMMUNICATION (IEEE RO-MAN), 2014, : 1056 - 1062
  • [32] Non-Contact Heart Rate Measurement From Facial Video Data Using a 2D-VMD Scheme
    Das, Mousumi
    Choudhary, Tilendra
    Bhuyan, M. K.
    Sharma, L. N.
    IEEE SENSORS JOURNAL, 2022, 22 (11) : 11153 - 11161
  • [33] A non-contact heart rate estimation method using video magnification and neural networks
    Moya-Albor, Ernesto
    Brieva, Jorge
    Ponce, Hiram
    Martinez-Villasenor, Lourdes
    IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2020, 23 (04) : 56 - 62
  • [34] NON-CONTACT PHOTOPLETHYSMOGRAM AND INSTANTANEOUS HEART RATE ESTIMATION FROM INFRARED FACE VIDEO
    Martinez, Natalia
    Bertran, Martin
    Sapiro, Guillermo
    Wu, Hau-Tieng
    2019 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2019, : 2020 - 2024
  • [35] An Emerging Method of the Non-contact Displacement Measurement by Video
    Ma, Jichen
    Xiao, Junjiang
    Liu, Ruolei
    Zhu, Jinlong
    PROCEEDINGS OF THE 2016 INTERNATIONAL FORUM ON ENERGY, ENVIRONMENT AND SUSTAINABLE DEVELOPMENT (IFEESD), 2016, 75 : 261 - 268
  • [36] Non-contact and real-time measurement of heart rate and heart rate variability using microwave reflectometry
    Mase, A.
    Kogi, Y.
    Maruyama, T.
    Tokuzawa, T.
    Sakai, F.
    Kunugita, M.
    Koike, T.
    Hasegawa, H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (01):
  • [37] A novel non-contact heart rate measurement method based on EEMD combined with FastICA
    Shi, Yingli
    Qiu, Jian
    Peng, Li
    Han, Peng
    Luo, Kaiqing
    Liu, Dongmei
    PHYSIOLOGICAL MEASUREMENT, 2023, 44 (05)
  • [38] Non-contact and through-clothing measurement of the heart rate using ultrasound vibrocardiography
    Jeger-Madiot, Nathan
    Gateau, Jerome
    Fink, Mathias
    Ing, Ros-Kiri
    MEDICAL ENGINEERING & PHYSICS, 2017, 50 : 96 - 102
  • [39] Live embryo detection using a non-contact heart rate measurement of chicken eggs
    Bakunda, John Ngunga
    Pongchalee, Pornthep
    Sutapun, Boonsong
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS VIII, 2018, 10821
  • [40] Non-contact detection of human heart rate with Kinect
    Liqian Zhou
    Ming Yin
    Xi Xu
    Xinpan Yuan
    Xiaojun Liu
    Cluster Computing, 2019, 22 : 8199 - 8206