Robotic Partial Nephrectomy with Indocyanine Green Fluorescence Navigation

被引:15
|
作者
Gadus, Lukas [1 ,2 ]
Kocarek, Jiri [3 ]
Chmelik, Frantisek [1 ]
Matejkova, Marketa [1 ]
Heracek, Jiri [3 ]
机构
[1] Mil Univ Hosp, Dept Urol, Prague 16902, Czech Republic
[2] Charles Univ Prague, Fac Med 1, Prague 12108, Czech Republic
[3] Charles Univ Prague, Dept Urol, Fac Med 1, Prague 12800, Czech Republic
关键词
LAPAROSCOPIC PARTIAL NEPHRECTOMY; RENAL-CELL CARCINOMA; CLAMP PARTIAL NEPHRECTOMY; OFF-CLAMP; RADICAL NEPHRECTOMY; ANGIOGRAPHY; OUTCOMES;
D O I
10.1155/2020/1287530
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Partial nephrectomy (PN) is a recommended type of treatment of localised renal tumors. Real-time intraoperative imaging technique, such as fluorescence imaging with indocyanine green (ICG) administration helps to improve intraoperative and postoperative outcomes in patients who underwent PN. Our work presents results of patients who underwent robotic PN with ICG navigation. A total of 37 patients underwent robotic PN with application of ICG between April 2015 and May 2019. A total amount of 5 mg of ICG was applied intravenously, and then robotic PN was performed with fluorescent imaging. ICG was used by the surgeon's decision according to unfavourable anatomical properties of tumor or to high R.E.N.A.L. nephrometry score. An exact border between perfused and nonperfused tissue was detected, and exact tumor's branch of the renal artery was clamped. Robotic PN with ICG-fluorescence imaging navigation was performed in 37 cases with a preoperative average diameter of tumor of 31 mm. The mean surgery time was 133 minutes, and the mean estimated blood loss was 190 mL. Arterial clamping was performed in 35 cases. The mean duration of warm ischemia was 14 minutes. Application of ICG enabled specific tumor-supplying vessel clamping in 25 cases. Two complications of grade II according to the Clavien-Dindo classification occurred intraoperatively, and one complication of grade III was observed. Renal function changes showed favourable results for the cases with superselective clamping. Finally, an administration of ICG eases superselective clamping of tumor-specific branch of renal artery and helps to preserve normal renal function with acceptable oncological results.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] "Ride the Green Light": Indocyanine Green-marked Off-clamp Robotic Partial Nephrectomy for Totally Endophytic Renal Masses
    Simone, Giuseppe
    Tuderti, Gabriele
    Anceschi, Umberto
    Ferriero, Mariaconsiglia
    Costantini, Manuela
    Minisola, Francesco
    Vallati, Giulio
    Pizzi, Giuseppe
    Guaglianone, Salvatore
    Misuraca, Leonardo
    Gallucci, Michele
    EUROPEAN UROLOGY, 2019, 75 (06) : 1008 - 1014
  • [42] Indocyanine green (ICG) fluorescence technology in pediatric robotic surgery
    Esposito, Ciro
    Masieri, Lorenzo
    Cerulo, Mariapina
    Castagnetti, Marco
    Del Conte, Fulvia
    Di Mento, Claudia
    Esposito, Giorgia
    Tedesco, Francesco
    Carulli, Roberto
    Continisio, Leonardo
    Chiodi, Annalisa
    Escolino, Maria
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)
  • [43] The Utility of Indocyanine Green Fluorescence Imaging During Robotic Adrenalectomy
    Colvin, Jennifer
    Zaidi, Nisar
    Berber, Eren
    JOURNAL OF SURGICAL ONCOLOGY, 2016, 114 (02) : 153 - 156
  • [44] Robotic Posterior Retroperitoneal Adrenalectomy with Indocyanine Green (ICG) Fluorescence
    Takahashi, H.
    Berber, E.
    ANNALS OF SURGICAL ONCOLOGY, 2017, 24 : S40 - S40
  • [45] INTRAOPERATIVE USE OF FLUORESCENCE IMAGING DURING ROBOTIC PARTIAL NEPHRECTOMY
    Donin, Nicholas
    Kim, Cadence
    Chiu, Jason
    Stifelman, Michael
    JOURNAL OF UROLOGY, 2012, 187 (04): : E163 - E164
  • [46] Editorial Comment to Laparoscopic partial nephrectomy for the horseshoe kidney with indocyanine green fluorescence guidance under the modified supine position
    Kanno, Toru
    IJU CASE REPORTS, 2022, 5 (04) : 263 - 263
  • [47] Real-time Vessel Navigation Using Indocyanine Green Fluorescence during Robotic or Laparoscopic Gastrectomy for Gastric Cancer
    Kim, Mina
    Son, Sang-Yong
    Cui, Long-Hai
    Shin, Ho-Jung
    Hur, Hoon
    Han, Sang-Uk
    JOURNAL OF GASTRIC CANCER, 2017, 17 (02) : 145 - 153
  • [48] Laparoscopic Repeat Hepatectomy with Indocyanine Green Fluorescence Navigation: A Case Report
    Yoshioka, Masato
    Taniai, Nobuhiko
    Kawano, Youichi
    Shimizu, Tetsuya
    Kondo, Ryota
    Kaneya, Yohei
    Aoki, Yuto
    Yoshida, Hiroshi
    JOURNAL OF NIPPON MEDICAL SCHOOL, 2019, 86 (05) : 291 - 295
  • [49] Utilization of indocyanine green for ureteral identification with robotic firefly fluorescence imaging
    Mueller, M. G.
    Abdeen, A.
    Kenton, K.
    Culligan, P.
    Glazier, D.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2020, 222 (03) : S843 - S843
  • [50] Indocyanine green (ICG) fluorescence in robotic hepatobiliary surgery: A systematic review
    Potharazu, Archit V.
    Gangemi, Antonio
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2023, 19 (01):