Poor results from the isoelastic total hip replacement - 14-17-year follow-up of 149 cementless prostheses

被引:33
|
作者
Trebse, R
Milosev, I
Kovac, S
Mikek, M
Pisot, V
机构
[1] Valdoltra Orthopaed Hosp, Ankaran 6280, Slovenia
[2] Jozef Stefan Inst, Dept Phys & Organ Chem, Ljubljana 1001, Slovenia
[3] Novo Mesto Gen Hosp, Novo Mesto 8000, Slovenia
关键词
D O I
10.1080/00016470510030535
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background To overcome the mismatch between a stiff stem and the more elastic bone, the concept of isoelasticity was introduced in the 1970s. This concept was based on the assumption that the implant and the bone should deform as one unit to avoid stress shielding. The Robert Mathys ( RM) cementless total hip replacement ( THR) was one of the earliest isoelastic designs. Patients and methods From 1984 to 1987, we performed 149 total hip replacements in 135 patients ( 92 women, mean age 47 ( 21 - 72) years) using third- generation Mathys isoelastic polyacetal stem with stainless-steel heads and polyethylene cementless acetabular cups. 11 patients died before revision or before the examination for this study, and 14 were lost to follow- up. Average follow- up time for the remaining 110 patients was 15 ( 14 - 17) years. Results To date, 69 hips ( 64 patients) have been revised, 5 due to infection. The 10- year survival rate for any reason was 70% ( 66 - 74). In the 46 remaining patients ( 53 hips), the average HHS was 80 ( 39 - 100) points. 13 of these were regarded as radiographic failures, with an average HHS of 75 points. Interpretation The performance of this prosthesis was unacceptably poor. Higher debris production and poor primary fixation are believed to be the main reason for the high failure rate.
引用
收藏
页码:169 / 176
页数:8
相关论文
共 50 条
  • [41] Cementless Total Hip Arthroplasty With a High Hip Center for Hartofilakidis Type B Developmental Dysplasia of the Hip: Results of Midterm Follow-Up
    Chen, Min
    Luo, Zheng-Liang
    Wu, Ke-Rong
    Zhang, Xiao-Qi
    Ling, Xiao-Dong
    Shang, Xi-Fu
    JOURNAL OF ARTHROPLASTY, 2016, 31 (05): : 1027 - 1034
  • [42] 3-YEAR FOLLOW-UP AFTER TOTAL HIP-REPLACEMENT FOR RADIOOSTEONECROSIS OF THE ACETABULUM
    AIGNER, C
    EHALL, R
    STAMPFEL, O
    WIENER KLINISCHE WOCHENSCHRIFT, 1995, 107 (23) : 726 - 730
  • [43] Patients on the waiting list for total hip replacement: a 1-year follow-up study
    Bachrach-Lindstrom, Margareta
    Karlsson, Susanne
    Pettersson, Lars-Goran
    Johansson, Torsten
    SCANDINAVIAN JOURNAL OF CARING SCIENCES, 2008, 22 (04) : 536 - 542
  • [44] Long-Term Results Using the Straight Tapered Femoral Cementless Hip Stem in Total Hip Arthroplasty: A Minimum of Twenty-Year Follow-Up
    Ateschrang, Atesch
    Weise, Kuno
    Weller, Siegfried
    Stoeckle, Ulrich
    de Zwart, Peter
    Ochs, Bjoern Gunnar
    JOURNAL OF ARTHROPLASTY, 2014, 29 (08): : 1559 - 1565
  • [45] TOTAL HIP-ARTHROPLASTY USING ISOELASTIC FEMORAL STEMS - A 7-YEAR TO 9-YEAR FOLLOW-UP IN 108 PATIENTS
    NIINIMAKI, T
    PURANEN, J
    JALOVAARA, P
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (03): : 413 - 418
  • [46] THE 5-YEAR TO 7-YEAR FOLLOW-UP RESULTS WITH THE RM ISOELASTIC HOP ENDOPROSTHESIS
    TRAGER, D
    UNFALLCHIRURG, 1989, 92 (06): : 301 - 304
  • [47] LONG-TERM RESULTS OF REVISION TOTAL HIP-REPLACEMENT - A FOLLOW-UP REPORT
    PELLICCI, PM
    WILSON, PD
    SLEDGE, CB
    SALVATI, EA
    RANAWAT, CS
    POSS, R
    CALLAGHAN, JJ
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (04): : 513 - 516
  • [48] Results of 10 years' follow-up of ceramic-ceramic couples in total hip replacement
    Mohajer, M. Azizbaig
    Plattner, F.
    Graf, R.
    BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2007, : 205 - 210
  • [49] Cementless total hip arthroplasty using a threaded cup and a rectangular tapered stem - Follow-up for ten to 17 years
    Pospischill, M
    Knahr, K
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (09): : 1210 - 1215
  • [50] THE VARIABILITY OF FOLLOW-UP BONE SCANS AFTER ASYMPTOMATIC TOTAL HIP PROSTHESES
    UTZ, JA
    LULL, RJ
    GALVIN, EG
    JOURNAL OF NUCLEAR MEDICINE, 1983, 24 (05) : P72 - P73