Boron neutron capture in prostate cancer cells

被引:17
|
作者
Yasui, Linda [1 ]
Kroc, Thomas [3 ]
Gladden, Samantha [1 ]
Andorf, Christine [4 ]
Bux, Sajit [2 ,5 ]
Hosmane, Narayan [2 ]
机构
[1] No Illinois Univ, Dept Biol Sci, De Kalb, IL 60115 USA
[2] No Illinois Univ, Dept Chem & Biochem, De Kalb, IL 60115 USA
[3] Fermilab Natl Accelerator Lab, Batavia, IL 60510 USA
[4] No Illinois Univ, Inst Neutron, Batavia, IL USA
[5] Kishwaukee Community Hosp, De Kalb, IL USA
基金
美国国家科学基金会;
关键词
Boron neutron capture; BPA; Cell survival; IN-VITRO; THERAPY; RADIATION; BOOST;
D O I
10.1016/j.apradiso.2011.07.001
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A modified enhanced thermal neutron beam (METNB) assembly at Fermilab was used to irradiate borylphenylalanine (BPA) treated human prostate cancer cells, DU 145. Acceptable cellular uptake levels of BPA and no BPA cytotoxicity were observed. In the absence of BPA, the relative biological effectiveness (RBE) of the METNB was determined to be 2.3-4.8 times greater than gamma rays. An additional 1.2 or 1.4 fold relative enhancement from boron neutron capture (REBNC) was observed for METNB irradiated DU 145 cells treated with 4.9 or 12 mM BPA, respectively. The additional cell killing of the BPA loaded DU 145 cells by the METNB at Fermilab is evidence for a BNC enhanced cell killing. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:6 / 12
页数:7
相关论文
共 50 条
  • [11] Boron delivery agents for neutron capture therapy of cancer
    Barth, Rolf F.
    Mi, Peng
    Yang, Weilian
    CANCER COMMUNICATIONS, 2018, 38 : 1 - 15
  • [12] Boron neutron capture therapy of cancer: Recent progress
    Li Zhao
    Weilian Yang
    Qing Lan
    Medicine Plus, 2024, 1 (03) : 30 - 33
  • [13] CANCER $40 million for boron neutron capture therapy
    Cross, Ryan
    CHEMICAL & ENGINEERING NEWS, 2018, 96 (12) : 13 - 13
  • [14] Neutron capture autoradiography for a study on boron neutron capture therapy
    Ogura, K
    Yamazaki, A
    Yanagie, H
    Eriguchi, M
    Lehmann, EH
    Küehne, G
    Bayon, G
    Maruyama, K
    Kobayashi, H
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 555 - 558
  • [15] Neutron dosimetry on phantom model of pancreatic cancer for boron neutron capture therapy
    Yanagie, H.
    Sakurai, Y.
    Ogura, K.
    Kobayashi, T.
    Furuya, Y.
    Sugiyama, H.
    Hisa, T.
    Ishikawa, M.
    Amemiya, K.
    Takahashi, H.
    Kobayashi, H.
    Tago, M.
    Masunaga, S.
    Ono, K.
    Nakagawa, K.
    Nakzawa, M.
    Eriguchi, M.
    KURRI Progress Report, 2003,
  • [16] Apoptosis of tumor cells in response to boron neutron capture therapy
    Yamamoto, T
    Matsumura, A
    Shibata, Y
    Yoshida, F
    Nakai, K
    Nose, T
    Horiguchi, Y
    Aizawa, M
    Nakajima, S
    Sakata, I
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 1293 - 1297
  • [17] Boron neutron capture therapy
    Kato, I
    ORAL ONCOLOGY, 2005, 1 (01) : 63 - 63
  • [18] Boron neutron capture therapy
    Beddoe, AH
    BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (835): : 665 - 667
  • [19] Boron Neutron Capture Therapy
    Kim, Kyung-O
    Kim, Soon Young
    Kim, Jong Kyung
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 197 - 200
  • [20] Boron neutron capture therapy
    Freemantle, M