Selection of fiducial locations and performance metrics for point-based rigid-body registration

被引:6
|
作者
Franaszek, Marek [1 ]
Cheok, Geraldine S. [1 ]
机构
[1] NIST, Gaithersburg, MD 20899 USA
关键词
Point-based rigid-body registration; Performance metrics; Noise and bias in positional data; LOCALIZATION ERROR; PLACEMENT; ACCURACY; IMAGE;
D O I
10.1016/j.precisioneng.2016.09.010
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A method is described to select the location and number of fiducials used in point-based, rigid-body reg. istration of two coordinate frames. Two indices are introduced which are used to search for the optimum configuration of fiducials. They can be used to quickly evaluate a large number of configurations because no actual registration is involved in their calculation. Furthermore, configurations yielding small values of the indices correlate well with configurations which result in optimum registrations. Three registration performance metrics are discussed, and it is shown that optimization of different metrics leads to different selection of fiducial configurations. If an optimized configuration is selected as a starting configuration of N fiducials, the addition of extra fiducials does not significantly improve the registration in most cases. This work is based on 3D data acquired with three different instruments, each having different noise and bias characteristics. Published by Elsevier Inc.
引用
收藏
页码:362 / 374
页数:13
相关论文
共 50 条
  • [21] ON THE ESTIMATION OF RIGID-BODY TRANSFORMATION FOR TLS REGISTRATION
    Scaioni, Marco
    XXII ISPRS CONGRESS, TECHNICAL COMMISSION V, 2012, 39-B5 : 601 - 606
  • [22] A statistical model for point-based target registration error with anisotropic fiducial localizer error
    Wiles, Andrew D.
    Likholyot, Alexander
    Frantz, Donald D.
    Peters, Terry M.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (03) : 378 - 390
  • [23] An Accurate Point-Based Rigid Registration Method for Laser Tracker Relocation
    Wan, An
    Xu, Jing
    Miao, Dongjing
    Chen, Ken
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (02) : 254 - 262
  • [24] Point-Based Non-Rigid Surface Registration with Accuracy Estimation
    Hontani, Hidekata
    Watanabe, Wataru
    2010 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2010, : 446 - 452
  • [25] Estimation of Rigid-Body Registration Quality Using Registration Networks
    Datteri, Ryan
    Dawant, Benoit M.
    MEDICAL IMAGING 2012: IMAGE PROCESSING, 2012, 8314
  • [26] A new feature-based method for robust and efficient rigid-body registration of overlapping point clouds
    Cagatay Basdogan
    A. Cengiz Oztireli
    The Visual Computer, 2008, 24 : 679 - 688
  • [27] A new feature-based method for robust and efficient rigid-body registration of overlapping point clouds
    Oztireli, A. Cengiz
    Basdogan, Cagatay
    VISUAL COMPUTER, 2008, 24 (7-9): : 679 - 688
  • [28] A Coordinate Frame Useful for Rigid-Body Displacement Metrics
    Venkataramanujam, Venkatesh
    Larochelle, Pierre M.
    JOURNAL OF MECHANISMS AND ROBOTICS-TRANSACTIONS OF THE ASME, 2010, 2 (04):
  • [29] ON THE METRICS OF RIGID-BODY DISPLACEMENTS FOR INFINITE AND FINITE BODIES
    MARTINEZ, JMR
    DUFFY, J
    JOURNAL OF MECHANICAL DESIGN, 1995, 117 (01) : 41 - 47
  • [30] Evaluating intraoperative rigid-body registration with the AWIGS system
    Knoop, H
    Raczkowsky, J
    Wyslucha, U
    Flegele, T
    Wörn, H