Accuracy assessment for infrared camera laboratory radiometric calibration

被引:0
|
作者
Xie Xu-fen [1 ]
Zhang Wei [1 ]
Nie Hong-bin [1 ]
Cao Yi-ming [1 ]
Wang Qiang [1 ]
Wang Hong-yuan [1 ]
机构
[1] Harbin Inst Technol, Res Ctr Space Opt Engn, Harbin 150080, Peoples R China
关键词
radiometric calibration; uncertainty; imaging chain; TM;
D O I
10.1117/12.900566
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An accuracy assessment method of infrared camera laboratory radiometric calibration was studied for the sake of validation of space infrared camera measured data. Firstly, image process of infrared camera was analyzed and modeled on laboratory radiometric calibration, a model of linear radiometric calibration coefficient synthesized impact chain was built; secondly, based on the model, a model of uncertainty of linear radiometric calibration coefficient was built; finally, An experiment verified the validity of the model. The results of experiment indicate that the difference between the assessment value and maximum experiment value is 0.08% and the difference between the assessment value and average of experiment values is 0.79% at gain uncertainty assessment, the difference between the assessment value and maximum experiment value is 0.7%, the difference between the assessment value and average of experiment values is 0.18% at offset uncertainty assessment, the uncertainty of coefficients of radiometric calibration get from experiments is basically consistent with the assessment. The method of accuracy assessment of radiometric calibration combined with chain factors uncertainty can avoid omitting and repetition in uncertainty estimation; optimization of camera used for quantification can be designed on the method.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Radiometric Calibration Accuracy of GOES Sounder Infrared Channels
    Yu, Fangfang
    Wu, Xiangqian
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2013, 51 (03): : 1187 - 1199
  • [2] Radiometric calibration of compact infrared camera (CIRC) for earth observation
    Kato, E. (katoh.eri@jaxa.jp), 1600, M Y U Scientific Publishing Division (26):
  • [3] Ad hoc radiometric calibration of a thermal-infrared camera
    Vidas, Stephen
    Moghadam, Peyman
    2013 INTERNATIONAL CONFERENCE ON DIGITAL IMAGE COMPUTING: TECHNIQUES & APPLICATIONS (DICTA), 2013, : 125 - 132
  • [4] Radiometric Calibration of Compact Infrared Camera (CIRC) for Earth Observation
    Kato, Eri
    Katayama, Haruyoshi
    Naitoh, Masataka
    Harada, Masatomo
    Nakamura, Ryoko
    Sakai, Michito
    Nakajima, Yasuhiro
    Nakau, Koji
    Tange, Yoshio
    Sato, Ryota
    SENSORS AND MATERIALS, 2014, 26 (04) : 199 - 214
  • [5] Absolute Radiometric Calibration Accuracy of the Atmospheric Infrared Sounder (AIRS)
    Pagano, Thomas S.
    Aumann, Hartmut H.
    Schindler, Rudolf
    Elliott, Denis
    Broberg, Steve
    Overoye, Kenneth
    Weiler, Margaret H.
    EARTH OBSERVING SYSTEMS XIII, 2008, 7081
  • [6] Radiometric calibration of photographic camera with a composite plane array CCD in laboratory
    Li J.
    Zhao J.-K.
    Chang M.
    Hu X.-R.
    Li, Jing (lijing@opt.ac.cn), 2017, Chinese Academy of Sciences (25): : 73 - 83
  • [7] RADIOMETRIC CALIBRATION OF A MULTISPECTRAL CAMERA
    Mansouri, A.
    Sanchez, M.
    Marzani, F. S.
    Gouton, P.
    COMPUTER VISION AND GRAPHICS (ICCVG 2004), 2006, 32 : 273 - 278
  • [8] Assessment of Camera Calibration Towards Accuracy Requirement
    Hassan, Mohd. Faizury Abol
    Ma'arof, Ismail
    Samad, Abd. Manan
    2014 IEEE 10TH INTERNATIONAL COLLOQUIUM ON SIGNAL PROCESSING & ITS APPLICATIONS (CSPA 2014), 2014, : 123 - 128
  • [9] Effects of point-spread function on calibration and radiometric accuracy of CCD camera
    Du, H
    Voss, KJ
    APPLIED OPTICS, 2004, 43 (03) : 665 - 670
  • [10] Radiometric calibration for InSb FPA camera
    Zahler, M
    INFRARED TECHNOLOGY AND APPLICATIONS XXIII, PTS 1 AND 2, 1997, 3061 : 850 - 857