The effects of heparin coated circuits on pulmonary injury -: A clinical study

被引:0
|
作者
Kazaz, H [1 ]
Oto, Ö [1 ]
Sariosmanoglu, N [1 ]
Hazan, E [1 ]
机构
[1] Dokuz Eylul Univ, Dept Thorac & Cardiovasc Surg, Izmir, Turkey
来源
JOURNAL OF CARDIOVASCULAR SURGERY | 2003年 / 44卷 / 05期
关键词
cardiopulmonary bypass; coated materials; biocompatible; heparin; complement activation; lung; physiopathology;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim Heparin-coated circuits have dramatic effects on the coagulation cascade, but their role on complement activation has not been clearly defined. in this clinical study the effect of heparin-coated circuits on static lung compliance and pulmonary vascular resistance is described. Methods. Thirty patients were randomly divided into two groups: with either a heparin-coated circuit or an identical but non-coated circuit control group. in the heparin-coated group, all the blood contacting surfaces were treated with immobilized heparin (Duraflo II.) Results. Early postoperative pulmonary function is determined with measurements of static lung compliance, pulmonary vascular resistance and arterial blood gases. Static lung compliance was significantly better in the heparin coated (HC) group in the early postoperative period (p=0.001). Pulmonary vascular resistance was significantly lower in the heparin-coated (HC) group in the early postoperative period (p=0.001). Conclusion. We believe that the method of heparin binding may play a role in its diminished effect on complement activation, but the general augmentation of the circuit's biocompatibility may explain its beneficial effect on pulmonary vascular resistance and static lung compliance.
引用
收藏
页码:611 / 615
页数:5
相关论文
共 50 条
  • [41] Heparin Coated Circuits Influence Tissue Factor Induction in Mononuclear Cell
    S Amato
    F Marotta
    M Pasino
    S Odino
    G Calza
    L Zannini
    P G Mori
    Pediatric Research, 1999, 45 : 764 - 764
  • [42] Sequestration of Antimicrobial Agents in Xcoating and Heparin-Coated Extracorporeal Membrane Oxygenation Circuits: An In Vitro Study
    Kato, Takafumi
    Enokiya, Tomoyuki
    Morikawa, Yoshihiko
    Okuda, Masahiro
    Imai, Hiroshi
    ASAIO JOURNAL, 2023, 69 (01) : E23 - E27
  • [43] CLINICAL SMOKE-INHALATION INJURY - PULMONARY EFFECTS
    HAPONIK, EF
    OCCUPATIONAL MEDICINE-STATE OF THE ART REVIEWS, 1993, 8 (03): : 431 - 468
  • [44] Complete heparin-coated (CBAS) cardio-pulmonary bypass and reduced systemic heparin dose; Effects on coagulation and fibrinolysis
    Ovrum, E
    Brosstad, F
    Holen, EA
    Tangen, G
    Abdelnoor, M
    Oystese, R
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1996, 10 (06) : 449 - 455
  • [45] Biocompatibility of heparin-coated cardiopulmonary bypass circuits in coronary patients with left ventricular dysfunction is superior to PMEA-coated circuits
    Kutay, Veysel
    Noyan, Tevfik
    Ozcan, Sedat
    Melek, Yasin
    Ekim, Hasan
    Yakut, Cevat
    JOURNAL OF CARDIAC SURGERY, 2006, 21 (06) : 572 - 577
  • [46] Heparin-coated cardiopulmonary bypass circuit: Clinical effects in pediatric cardiac surgery
    Miyaji, K
    Hannan, RL
    Ojito, J
    Jacobs, JP
    White, JA
    Burke, RP
    JOURNAL OF CARDIAC SURGERY, 2000, 15 (03) : 194 - 198
  • [47] Heparin-bonded circuits: clinical outcomes and costs
    Mahoney, C. Brown
    PERFUSION-UK, 1998, 13 (03): : 192 - 204
  • [48] Effects of heparin and lisofylline on pulmonary function after smoke inhalation injury in an ovine model
    Tasaki, O
    Mozingo, DW
    Dubick, MA
    Goodwin, CW
    Yantis, LD
    Pruitt, BA
    CRITICAL CARE MEDICINE, 2002, 30 (03) : 637 - 643
  • [49] Heparin-coated circuits reduce occult myocardial damage during CPB:: a randomized, single blind clinical trial
    Belboul, A
    Löfgren, C
    Storm, C
    Jungbeck, M
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (05) : 580 - 586
  • [50] Experimental pulmonary embolism: Effects of the thrombus and attenuation of pulmonary artery injury by low-molecular-weight heparin
    Rectenwald, JE
    Deatrick, KB
    Sukheepod, P
    Lynch, EM
    Moore, AJ
    Moaveni, DM
    Deywer, NA
    Luke, CE
    Upchurch, GR
    Wakefield, TW
    Kunkel, SL
    Henke, PK
    JOURNAL OF VASCULAR SURGERY, 2006, 43 (04) : 800 - 808