PV module degradation analysis and impact on settings of overcurrent protection devices

被引:41
|
作者
Dhoke, Amit [1 ]
Sharma, Rahul [1 ]
Saha, Tapan Kumar [1 ]
机构
[1] Univ Queensland, Sch Informat Technol & Elect Engn, Brisbane, Qld 4072, Australia
关键词
PV module; Degradation; Fuse; Fault current; PV system; String fault; SILICON PHOTOVOLTAIC MODULES; SYSTEMS; PERFORMANCE; FAULTS; RELIABILITY; CHALLENGES; PARAMETERS; ARRAYS;
D O I
10.1016/j.solener.2017.12.013
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Degradation of photovoltaic (PV) modules is inevitable regardless of the size of a PV plant. While it is understood that degradation leads to a reduction in power generation, the effects of module degradation on PV plant protection system remains somewhat unclear. Considering that most of the PV plant protection system settings are based on modules in good conditions without degradation, it is imperative to evaluate the effect of module degradation on fault detectability by conventional protection infrastructure to ensure safety and reliability of PV plants. The purpose of this paper is to investigate the relationship between the levels of module degradation and PV plant faults including fault current levels, fault locations and types of faults. An experimental setup comprising of 16 modules of varying degradation levels is used to generate multiple short circuit fault scenarios. The results indicate that degradation results in a decrease in string current, which may lead to an increased likelihood of fault undetectability using conventional protection settings.
引用
收藏
页码:360 / 367
页数:8
相关论文
共 50 条
  • [41] State of Art of Fault Current Limiters and their Impact on Overcurrent Protection
    Orpe, S.
    Nair, Nirmal-Kumar C.
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 483 - 487
  • [42] Impact of hailstorm on the performance of PV module: a review
    Gupta, Vinay
    Sharma, Madhu
    Pachauri, Rupendra
    Babu, K. N. Dinesh
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2022, 44 (01) : 1923 - 1944
  • [43] Coordination of the Time Overcurrent Relay Protection Settings in Medium Voltage Electric Power Grids
    Mehmed-Hamza, Mediha
    Stanchev, Plamen
    7TH INTERNATIONAL CONFERENCE ON ENERGY EFFICIENCY AND AGRICULTURAL ENGINEERING (EE&AE), 2020,
  • [44] On Differences between Bathtub Curves and Linear Degradation Describing PV Module Degradation
    von Roedern, Bolko
    RELIABILITY OF PHOTOVOLTAIC CELLS, MODULES, COMPONENTS, AND SYSTEMS VI, 2013, 8825
  • [45] Impact of Renewable Energy Integration on Overcurrent Protection in Distribution Network
    Yuan, Huan
    Guan, Zhe
    Kong, Hanjie
    Zhang, Baohui
    Huang, Renmou
    Wu, Weiming
    Li, Ye
    Guo, Danyang
    2015 27TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2015, : 5111 - 5116
  • [46] Impact of PV Module Mismatch on the PV Array Energy Yield and Comparison of Module, String and Central MPPT
    Bakas, Panagiotis
    Marinopoulos, Antonis
    Stridh, Bengt
    2012 38TH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2012, : 1393 - 1398
  • [47] Meeting USB and IEEE 1394 overcurrent protection requirements using PolySwitch devices
    Wiener, P
    Witham, J
    WESCON/97 - CONFERENCE PROCEEDINGS, 1997, : 442 - 475
  • [48] Accurate Analysis of Solar PV Module
    Kumar, Alok
    Gupta, Rajesh
    2018 INTERNATIONAL CONFERENCE ON COMPUTING, POWER AND COMMUNICATION TECHNOLOGIES (GUCON), 2018, : 467 - 471
  • [49] Coordination of Conductors and Overcurrent Protecting Devices, for Protection against Sustained Overloads.
    Toniolo, S.B.
    Elettrotecnica, 1974, 61 (3 bis): : 285 - 288
  • [50] Image Analysis of PV Module Electroluminescence
    Lai, T.
    Ramirez, C.
    Potter, B. G., Jr.
    Simmons-Potter, K.
    RELIABILITY OF PHOTOVOLTAIC CELLS, MODULES, COMPONENTS, AND SYSTEMS X, 2017, 10370