A Year Around System Simulation for An Experimental Set-Up of A Thermosyphon Solar Water Heater in Thailand

被引:0
|
作者
Ekanayake, E. M. U. N. [1 ]
Limmeechokchai, Bundit [2 ]
机构
[1] Univ Peradeniya, Dept Elect & Elect Engn, Peradeniya, Sri Lanka
[2] Thammasat Univ, SIIT, Mech Engn Program, Sustainable Energy & Low Carbon Res Unit, Pathum Thani, Thailand
关键词
Thermo-syphon solar water heater; Solar Collector Efficiency; Collector Temperature; Collector Operating Point; Renewable Energy;
D O I
10.1109/icue49301.2020.9307043
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Due to the high cost and environmental impacts fossil fuel, solar energy remains the most efficient alternative source of energy for water heating. A Solar Water Heater is a widely used apparatus in Thailand as an application of solar thermal energy. In this project a prevailing experimental set up of a thermosyphon solar water heater was used to experiment, model and simulate the yearly performance. The results of the simulations were based on a solar water with a collector surface of 2.16 m(2), facing south with a tilt angle of 14 degrees and a storage tank of 150 litres, operated at SIIT, Thammasat University in Pathum Thani. After the experimental data modelling a yearly simulation was carried using solar radiation levels and ambient temperatures as inputs to the simulation. After the yearly simulation, the average collector efficiency is 49 %, average collector temperature is 48 degrees C and average Storage temperature is 47 degrees C.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Experimental investigation of temperature and flow distribution in a thermosyphon solar water heating system
    Chuawittayawuth, K
    Kumar, S
    RENEWABLE ENERGY, 2002, 26 (03) : 431 - 448
  • [32] An Experimental Study of PCM-Incorporated Thermosyphon Solar Water Heating System
    Murali, G.
    Mayilsamy, K.
    Arjunan, T. V.
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2015, 12 (09) : 978 - 986
  • [33] Experimental studies on heat transfer and friction factor characteristics of thermosyphon solar water heater system fitted with spacer at the trailing edge of twisted tapes
    Jaisankar, S.
    Radhakrishnan, T. K.
    Sheeba, K. N.
    APPLIED THERMAL ENGINEERING, 2009, 29 (5-6) : 1224 - 1231
  • [34] Modeling, simulation and experimental set-up of a renewable hydrogen-based domestic microgrid
    Valverde, L.
    Rosa, F.
    del Real, A. J.
    Arce, A.
    Bordons, C.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2013, 38 (27) : 11672 - 11684
  • [35] Spatial double physical pendulum with axial excitation: computer simulation and experimental set-up
    Ludwicki M.
    Awrejcewicz J.
    Kudra G.
    International Journal of Dynamics and Control, 2015, 3 (01) : 1 - 8
  • [36] THEORETICAL AND EXPERIMENTAL INVESTIGATION OF THE EVACUATED TUBE SOLAR WATER HEATER SYSTEM
    Sakulchangsatjatai, Phrut
    Wannagosit, Chaiwat
    Kammuang-Lue, Niti
    Terdtoon, Pradit
    THERMAL SCIENCE, 2020, 24 (02): : 795 - 808
  • [37] EXPERIMENTAL SET-UP AND NUMERICAL SIMULATION OF A METHANE-LEAN OXYGEN DIFFUSION FLAME
    Prisecaru, Tudor
    Prisecaru, Malina
    Stanciu, Dorin
    Dobrovicescu, Alexandru
    METALURGIA INTERNATIONAL, 2010, 15 (05): : 62 - 67
  • [38] Experimental set-up with a linear motor drive system for magnetorheological dampers testing
    Jastrzebski, Lukasz
    Micek, Piotr
    2024 25TH INTERNATIONAL CARPATHIAN CONTROL CONFERENCE, ICCC 2024, 2024,
  • [39] STUDYING THE WATER REGIME OF THE SOIL - PLANT SYSTEM IN A STRESS DIAGNOSIS SET-UP
    Farkas, Csilla
    Csorba, Szilveszter
    Lukacs, Andras
    CEREAL RESEARCH COMMUNICATIONS, 2008, 36 : 1703 - 1706
  • [40] Dynamic Modelling of a Water Distribution Laboratory set-up System with SCADA Capabilities
    Sahlan, Shafishuhaza
    Eek, Rickey Ting Pek
    Anuar, Aiman Najmi
    Rosli, Khairul Ijlal
    Ab Rahim, Mohamad Fadzli
    Shan, Tan Wen
    Hasan, Nur Shahida
    Manaf, Mohamad Shukri Abdul
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2022, 14 (01): : 203 - 214