Characterisation of adjacent pits with combined application of MFL and laser scanning techniques

被引:0
|
作者
Azizzadeh, T. [1 ]
Safizadeh, M. S. [1 ]
机构
[1] Iran Univ Sci & Technol, Dept Mech Engn, Tehran 16887, Iran
关键词
laser scanning; MFL; combination; adjacent pitting corrosion;
D O I
10.1784/insi.2018.60.2.84
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The most common corrosion defect found in pipelines is adjacent pits. Adjacent pits are a group of individual pits interacting with each other. Due to their geometry, discriminating between these defects and accurately sizing them is not possible using the traditional magnetic flux leakage (MFL) technique. Significant improvements in depth sizing accuracy can be obtained if sizing models can be optimised on high-resolution data that allows the shapes and actual dimensions of the adjacent pits to be more clearly discerned. This paper presents a new combination method of MFL and high-resolution laser scanning techniques for improving the accuracy of depth sizing of adjacent pits. MFL and laser scanning experiments have been conducted in a laboratory set-up on pits with different edge-to-edge distances. The results of the new combination method reveal how the additional laser scanning data, which allows increased distinction of individual pits, can help the MFL sizing model and improve the depth sizing accuracy.
引用
收藏
页码:84 / +
页数:7
相关论文
共 50 条
  • [31] Novel experimental techniques for semiconductor laser characterisation and optimisation
    Sweeney, Stephen J.
    PHYSICA SCRIPTA, 2004, T114 : 152 - 158
  • [32] EFFICIENT APPLICATION OF LASER SCANNING SYSTEM
    Nesterenko, E. A.
    JOURNAL OF MINING INSTITUTE, 2012, 199 : 344 - 348
  • [33] Experimental characterisation of a proton kernel model for pencil beam scanning techniques
    De Marzi, L.
    Da Fonseca, A.
    Moignier, C.
    Patriarca, A.
    Goudjil, F.
    Mazal, A.
    Buvat, I
    Herault, J.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 195 - 203
  • [34] Scanning techniques applied to the characterisation of P and N type multicrystalline silicon
    Martinuzzi, S.
    Palais, O.
    Ostapenko, S.
    MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING, 2006, 9 (1-3) : 230 - 235
  • [35] APPLICATION OF STEREOGRAPHIC TECHNIQUES TO SCANNING ELECTRON MICROSCOPE
    LANE, GS
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1969, 2 (07): : 565 - &
  • [36] Contemporary application of classical techniques in thyroid scanning
    Roman Junik
    Thyroid Research, 8 (Suppl 1)
  • [37] Assisted Scanning Techniques Optimization with Application in Biomechanics
    Braun, B. C.
    Rosca, I. C.
    Druga, C. N.
    Ionescu, M.
    INTERNATIONAL CONFERENCE ON ADVANCEMENTS OF MEDICINE AND HEALTH CARE THROUGH TECHNOLOGY, 2011, 36 : 376 - +
  • [38] APPLICATION OF INFORMATION EXTRACTION TECHNIQUES TO HUMAN SCANNING
    SOLOMON, AK
    FRIEDELL, HL
    QUASTERL.H
    SCIENCE, 1962, 136 (3519) : 885 - &
  • [39] Development of techniques for characterisation of scintillation materials for cryogenic application
    Mikhailik, V. B.
    Kraus, H.
    RADIATION MEASUREMENTS, 2013, 49 : 7 - 12
  • [40] SURFACE ANALYSIS TECHNIQUES AND THEIR APPLICATION TO MATERIALS CHARACTERISATION.
    Harris, P.G.
    Trigg, A.D.
    Materials and Design, 1988, 9 (03): : 127 - 134