Accelerated Cardiac T2 Mapping using Breath-hold Multiecho Fast Spin-Echo Pulse Sequence with k-t FOCUSS

被引:69
|
作者
Feng, Li [2 ]
Otazo, Ricardo [1 ]
Jung, Hong [3 ]
Jensen, Jens H. [1 ]
Ye, Jong C. [3 ]
Sodickson, Daniel K. [1 ]
Kim, Daniel [1 ]
机构
[1] NYU, Dept Radiol, Sch Med, Ctr Biomed Imaging, New York, NY 10012 USA
[2] NYU, Sch Med, Sackler Inst Grad Biomed Sci, New York, NY USA
[3] Korea Adv Inst Sci & Technol, Dept Bio & Brain Engn, Bioimaging & Signal Proc Lab, Taejon 305701, South Korea
基金
美国国家卫生研究院;
关键词
MRI; heart; multiecho FSE; T-2; compressed sensing; parallel imaging; k-t FOCUSS; CARDIOVASCULAR MAGNETIC-RESONANCE; MYOCARDIAL-INFARCTION; MRI; HEART; EDEMA; SENSE;
D O I
10.1002/mrm.22756
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cardiac T-2 mapping is a promising method for quantitative assessment of myocardial edema and iron overload. We have developed a new multiecho fast spin echo (ME-FSE) pulse sequence for breath-hold T-2 mapping with acceptable spatial resolution. We propose to further accelerate this new ME-FSE pulse sequence using k-t focal underdetermined system solver adapted with a framework that uses both compressed sensing and parallel imaging (e. g., sensitivity encoding) to achieve higher spatial resolution. We imaged 12 control subjects in midventricular short-axis planes and compared the accuracy of T-2 measurements obtained using ME-FSE with generalized autocalibrating partially parallel acquisitions and ME-FSE with k-t focal underdetermined system solver. For image reconstruction, we used a bootstrapping two-step approach, where in the first step fast Fourier transform was used as the sparsifying transform and in the final step principal component analysis was used as the sparsifying transform. When compared with T-2 measurements obtained using generalized autocalibrating partially parallel acquisitions, T-2 measurements obtained using k-t focal underdetermined system solver were in excellent agreement (mean difference = 0.04 msec; upper/lower 95% limits of agreement were 2.26/-22.19 msec, respectively). The proposed accelerated ME-FSE pulse sequence with k-t focal underdetermined system solver is a promising investigational method for rapid T-2 measurement of the heart with relatively high spatial resolution (1.7 x 1.7 mm(2)). Magn Reson Med 65:1661-1669, 2011. (C) 2011 Wiley-Liss, Inc.
引用
收藏
页码:1661 / 1669
页数:9
相关论文
共 50 条
  • [21] MR of focal liver lesions: Comparison of breath-hold and non-breath-hold hybrid RARE and conventional spin-echo T2-weighted pulse sequences
    Carpenter, KD
    Macaulay, SE
    Schulte, SJ
    Obregon, RG
    Nelson, RC
    Simon, HE
    Schmiedl, UP
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04): : 596 - 602
  • [22] Hepatic iron deposition in patients with sickle cell disease: Role of breath-hold multiecho T2*-weighted MRI sequence
    Awad, Fatma Mohamed
    Alshazly, Shereen Ahmed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2014, 45 (03): : 651 - 655
  • [23] Radial fast spin-echo method for T2-weighted imaging and T2 mapping of the liver
    Altbach, MI
    Outwater, EK
    Trouard, TP
    Krupinski, EA
    Theilmann, RJ
    Stopeck, AT
    Kono, M
    Gmitro, AF
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (02) : 179 - 189
  • [24] Evaluation of a single-breath-hold radial turbo-spin-echo sequence for T2 mapping of the liver at 3T
    Bencikova, Dianas
    Han, Fei
    Kannengieser, Stephan
    Raudner, Marcus
    Poetter-Lang, Sarah
    Bastati, Nina
    Reiter, Gert
    Ambros, Raphael
    Ba-Ssalamah, Ahmed
    Trattnig, Siegfried
    Krssak, Martin
    EUROPEAN RADIOLOGY, 2022, 32 (05) : 3388 - 3397
  • [25] Evaluation of a single-breath-hold radial turbo-spin-echo sequence for T2 mapping of the liver at 3T
    Diana Bencikova
    Fei Han
    Stephan Kannengieser
    Marcus Raudner
    Sarah Poetter-Lang
    Nina Bastati
    Gert Reiter
    Raphael Ambros
    Ahmed Ba-Ssalamah
    Siegfried Trattnig
    Martin Krššák
    European Radiology, 2022, 32 : 3388 - 3397
  • [26] A Technique for Rapid Single-Echo Spin-Echo T2 Mapping
    Sussman, Marshall S.
    Vidarsson, Logi
    Pauly, John M.
    Cheng, Hai-Ling Margaret
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (02) : 536 - 545
  • [27] Breath-hold fast recovery fast spin echo versus conventional non-breath-hold fast spin echo T2-weighted MR imaging of focal liver lesions
    Tseng, GY
    Thng, CH
    Wong, EH
    Tan, AGS
    Suman, P
    Quek, ST
    Ho, JTS
    Khoo, JKB
    Ooi, LLPJ
    Chow, PKH
    Chung, YFA
    Teh, CSC
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2003, 32 (04) : 450 - 454
  • [28] Fat-saturated dark-blood cardiac T2 mapping in a single breath-hold
    Hu, Chenxi
    Huber, Steffen
    Nguyen, Vinh
    Baldassarre, Lauren
    Mojibian, Hamid
    Peters, Dana
    MAGNETIC RESONANCE IMAGING, 2021, 81 : 24 - 32
  • [29] Feasibility of application of sensitivity encoding to the breath-hold T2-weighted turbo spin-echo sequence for evaluation of focal hepatic tumors
    Kim, YK
    Kim, CS
    Chung, GH
    Bin Jeon, S
    Lee, JM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) : 497 - 504