4D Lung Reconstruction with Phase Optimization

被引:0
|
作者
Lyksborg, Mark [1 ]
Paulsen, Rasmus [1 ]
Brink, Carsten [2 ]
Larsen, Rasmus [1 ]
机构
[1] Tech Univ Denmark, Informat & Math Modeling, Bldg 321, DK-2800 Lyngby, Denmark
[2] Odense Univ Hosp, Lab Radiat Phys, DK-5000 Odense M, Denmark
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS | 2010年 / 25卷
关键词
Registration; Motion Correction; 4D Lung CT; L-BFGS; Optimization;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper investigates and demonstrates a 4D lung CT reconstruction/registration method which results in a complete volumetric model of the lung that deforms according to a respiratory motion field. The motion field is estimated iteratively between all available slice samples and a reference volume which is updated on the fly. The method is two part and the second part of the method aims to correct wrong phase information by employing another iterative optimizer. This two part iterative optimization allows for complete reconstruction at any phase and it will be demonstrated that it is better than using an optimization which does not correct for phase errors. Knowing how the lung and any tumors located within the lung deforms is relevant in planning the treatment of lung cancer.
引用
收藏
页码:2227 / 2230
页数:4
相关论文
共 50 条
  • [11] PRIOR: Prior-Regularized Iterative Optimization Reconstruction For 4D CBCT
    Hu, Dianlin
    Zhang, Yikun
    Liu, Jin
    Zhang, Yi
    Coatrieux, Jean Louis
    Chen, Yang
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (11) : 5551 - 5562
  • [12] Validation of 4D CT Image Reconstruction Using a 3D Lung Phantom
    Zheng, Y.
    Girbino, M.
    Oshinsky, R.
    Vroege, L.
    Jesseph, F.
    Lee, S.
    Yuan, J.
    Machtay, M.
    Sohn, J.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [13] 4D Dose Reconstruction in Lung From Discontinuous Cyclotron Proton Beam Delivery
    Ugarte, V.
    Yeo, I.
    Ghebremedhin, A.
    Patyal, B.
    MEDICAL PHYSICS, 2018, 45 (06) : E257 - E257
  • [14] Optimization of 4D PET/CT
    Pan, Tinsu
    Mawlawi, Osama
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [15] A parallelized 4D reconstruction algorithm for vascular structures and motions based on energy optimization
    Xinglong Liu
    Fei Hou
    Aimin Hao
    Hong Qin
    The Visual Computer, 2015, 31 : 1431 - 1446
  • [16] A parallelized 4D reconstruction algorithm for vascular structures and motions based on energy optimization
    Liu, Xinglong
    Hou, Fei
    Hao, Aimin
    Qin, Hong
    VISUAL COMPUTER, 2015, 31 (11): : 1431 - 1446
  • [17] Optimal gating compared to 3D and 4D PET reconstruction for characterization of lung tumours
    Wouter van Elmpt
    James Hamill
    Judson Jones
    Dirk De Ruysscher
    Philippe Lambin
    Michel Öllers
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 843 - 855
  • [18] Optimal gating compared to 3D and 4D PET reconstruction for characterization of lung tumours
    van Elmpt, Wouter
    Hamill, James
    Jones, Judson
    De Ruysscher, Dirk
    Lambin, Philippe
    Ollers, Michel
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (05) : 843 - 855
  • [19] 4D Iterative Reconstruction in Cardiac CT
    Bruder, H.
    Raupach, R.
    Allmendinger, T.
    Sunnegardh, J.
    Stierstorfer, K.
    Flohr, T.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [20] 4D image reconstruction for emission tomography
    Reader, Andrew J.
    Verhaeghe, Jeroen
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (22): : R371 - R418