Lymph node extraction of radiopaque nanoparticulates in the rabbit as measured in vivo with CT

被引:12
|
作者
Wolf, GL
Shore, MT
Bessin, G
McIntire, GL
Bacon, ER
Illig, KJ
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Ctr Imaging & Pharmaceut Res, Boston, MA 02114 USA
[2] Nycomed, Wayne, PA USA
关键词
percutaneous lymphography; radiopaque nanoparticulates; in vivo physiology; rabbit; computer tomography;
D O I
10.1016/S1076-6332(99)80062-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The purpose of this study was to estimate in vivo extraction of lymphographic material in the popliteal node of the rabbit. Materials and Methods. Serial quantitative computed tomography (CT) of target tissues in four legs of two rabbits was performed after subcutaneous injection of an improved lymphographic contrast agent. Massage was used as a lymphotrophic intervention. Results. At 15 minutes, the mean change in Hounsfield units measured 815 in the popliteal node, 219 in afferent lymphatic vessels, and 127 in efferent lymphatic vessels. The nodal extraction of nanoparticulates from the lymph was approximately 55%. Nodal massage allowed the amount of nanoparticulate remaining in sinusoidal lymph to be estimated. Conclusion. Functional CT performed with timed studies, proper radiopaque materials, and physiologic interventions can depict in vivo lymphatic physiology under minimally invasive conditions.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 50 条
  • [31] Tumor size measured by multidetector CT in resectable colon cancer: correlation with regional lymph node metastasis and N stage
    Mou, Anna
    Li, Hang
    Chen, Xiao-li
    Fan, Yang-hua
    Pu, Hong
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2021, 19 (01)
  • [32] Tumor size measured by multidetector CT in resectable colon cancer: correlation with regional lymph node metastasis and N stage
    Anna Mou
    Hang Li
    Xiao-li Chen
    Yang-hua Fan
    Hong Pu
    World Journal of Surgical Oncology, 19
  • [33] SPECT CT in breast sentinel lymph node scintigraphy
    Dosoretz, C. L.
    Horin, Ben
    Vainshtein, P.
    Yoffe, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S225 - S225
  • [34] In vivo lymph node CEST-Dixon MRI in breast cancer patients with metastatic lymph node involvement
    Donahue, Manus J.
    Donahue, Paula M. C.
    Jones, R. Sky
    Garza, Maria
    Lee, Chelsea
    Patel, Niral J.
    Cooper, Andrea
    De Vis, Jill B.
    Meszoely, Ingrid
    Crescenzi, Rachelle
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (02) : 670 - 680
  • [35] Lymph node staging in gastrointestinal cancer. Combination of methylene blue-assisted lymph node dissection and ex vivo sentinel lymph node mapping
    Maerkl, B.
    Arnholdt, H.
    PATHOLOGE, 2012, 33 : 325 - 330
  • [36] LYMPH-NODE METASTASES - DIAGNOSIS BY LYMPHOGRAPHY AND CT
    FEUERBACH, S
    RUPP, N
    ROSSMANN, W
    HELLER, HJ
    ROTHENBERGER, G
    TAUBER, R
    SCHMIDT, G
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1979, 130 (03): : 323 - 328
  • [37] Pancreatoblastoma With Metastatic Retroperitoneal Lymph Node and PET/CT
    Corrias, Giuseppe
    Ragucci, Monica
    Basturk, Olca
    Saba, Luca
    Mannelli, Lorenzo
    CLINICAL NUCLEAR MEDICINE, 2017, 42 (11) : E482 - E483
  • [38] Automatic Mediastinal Lymph Node Detection in Chest CT
    Feuerstein, Marco
    Deguchi, Daisuke
    Kitasaka, Takayuki
    Iwano, Shingo
    Imaizumi, Kazuyoshi
    Hasegawa, Yoshinori
    Suenaga, Yasuhito
    Mori, Kensaku
    MEDICAL IMAGING 2009: COMPUTER-AIDED DIAGNOSIS, 2009, 7260
  • [39] Mirror-Image Lymph Node in FDG PET/CT and SPECT/CT for Sentinel Node Detection
    Domenech, Beatriz
    Paredes, Pilar
    Rubi, Sebastia
    Pahisa, Jaume
    Vidal-Sicart, Sergi
    Pons, Francesca
    CLINICAL NUCLEAR MEDICINE, 2014, 39 (03) : E241 - E242
  • [40] In vivo differences of cement quality measured with CT
    Werhahn, C
    Neubert, O
    Zwonitzer, R
    CAR '97 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1997, 1134 : 73 - 78