Rate-scanning modified adiabatic calorimeter

被引:11
|
作者
Moon, IK [1 ]
Jeong, YH [1 ]
机构
[1] POHANG UNIV SCI & TECHNOL,BASIC SCI RES CTR,KYUNGBUK 790784,SOUTH KOREA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1996年 / 67卷 / 10期
关键词
D O I
10.1063/1.1147063
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have developed a continuous cooling method, as a simple modification of adiabatic calorimetry which typically operates in the heating mode, with the capability of varying the scanning rate in the range of 0.01-2 K/min. This method allows us to determine the absolute value of specific heat of a liquid or solid during cooling as well as during heating in the temperature range between 100 and 400 K. The typical specific heat data of a supercooled liquid [Ca(NO3)(2)](0.4)(KNO3)(0.6) agree well with results by other methods. (C) 1996 American Institute of Physics.
引用
收藏
页码:3553 / 3556
页数:4
相关论文
共 50 条
  • [21] Enthalpy of solution of carbohydrates using a modified differential scanning calorimeter
    Schwarz, FP
    JOURNAL OF SOLUTION CHEMISTRY, 1996, 25 (05) : 471 - 484
  • [22] Studies of thermokinetics in an adiabatic calorimeter .1. Design and testing of an adiabatic automatic calorimeter
    Zhan, S
    Liu, J
    Qin, Z
    Deng, Y
    JOURNAL OF THERMAL ANALYSIS, 1995, 45 (06): : 1403 - 1410
  • [23] Enthalpy of Solution of Carbohydrates Using a Modified Differential Scanning Calorimeter
    Ctr. for Adv. Res. in Biotechnology, Natl. Inst. of Std. and Technology, 9600 Gudelsky Drive, Rockville, MD 20850, United States
    J. Solut. Chem., 5 (471-484):
  • [24] NOTE TO ARTICLE - DESIGN AND APPLICATION OF ON ADIABATIC CALORIMETER FOR MEASURING DOSE RATE IN A REACTOR
    STOLTE, S
    ATOMKERNENERGIE, 1970, 16 (01): : 90 - &
  • [25] ADIABATIC CALORIMETER FOR SMALL SAMPLES
    TUNNICLIFF, DD
    BADLEY, JH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1960, 31 (09): : 953 - 958
  • [26] ADAPTATION OF AN ADIABATIC CALORIMETER TO LIQUIDS
    SEMMAR, N
    TANGUIER, JL
    KLEINCLAUSS, J
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1994, 37 (08) : 1227 - 1233
  • [27] THERMAL REGULATOR FOR ADIABATIC CALORIMETER
    GERASIMOV, VV
    EMELYANO.KA
    TOPCHAN, LS
    INDUSTRIAL LABORATORY, 1969, 35 (07): : 1063 - +
  • [28] IMPROVED ADIABATIC TITRATION CALORIMETER
    AMDUR, S
    MARINSKY, JA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1973, 44 (09): : 1234 - 1238
  • [29] FOIL ADIABATIC CALORIMETER.
    Suchkov, V.P.
    Tarasov, M.D.
    Shcherbak, Yu.P.
    Instruments and experimental techniques New York, 1987, 30 (5 Pt 1): : 1076 - 1080
  • [30] Development of an adiabatic laser calorimeter
    Kawate, E
    Hanssen, LM
    Kaplan, SG
    Datla, RV
    OPTICAL DIAGNOSTIC METHODS FOR INORGANIC MATERIALS II, 2000, 4103 : 133 - 144