Method of thickness measurement for transparent specimens with chromatic confocal microscopy

被引:49
|
作者
Yu, Qing [1 ]
Zhang, Kun [1 ]
Cui, Changcai [2 ]
Zhou, Ruilan [1 ]
Cheng, Fang [1 ]
Ye, Ruifang [1 ]
Zhang, Yi [1 ]
机构
[1] Huaqiao Univ, Coll Mech Engn & Automat, Xiamen 361021, Peoples R China
[2] Huaqiao Univ, Inst Mfg Technol, Xiamen 361021, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
10.1364/AO.57.009722
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this paper, a new method for measuring the thickness of transparent specimens using chromatic confocal microscopy (CCM) is presented. The conventional CCM thickness measurement model relies on capturing the focal points on the upper and lower surfaces of a transparent specimen. This model has strict specimen placement tolerance and a limited measurement range. In order to overcome these limitations, a new thickness measurement model was developed by adding an auxiliary reflector below the specimen. The thickness of the specimen can be determined by comparing the wavelengths of light focused on the auxiliary reflector before and after placing the measurement specimen. Theoretical analysis and simulation showed that the proposed method has twice the measurement range of the conventional model. In order to verify the proposed CCM measurement model, a laboratory thickness measurement system was developed by the authors' team. A commercial laser scanning confocal microscope (Carl Zeiss LSM780) was used as the reference system. A set of quartz glasses was measured using both the proposed system and the reference system. Experimental comparison showed that the proposed method was able to achieve a measurement accuracy of 0.25 mu m. In addition, repeated measurements conducted at different heights showed negligible variation. Thus, it can be concluded that the specimen placement tolerance was improved significantly compared with the conventional model. (C) 2018 Optical Society of America
引用
收藏
页码:9722 / 9728
页数:7
相关论文
共 50 条
  • [41] Chromatic confocal microscopy with a finite pinhole size
    Ruprecht, AK
    Wiesendanger, TF
    Tiziani, HJ
    OPTICS LETTERS, 2004, 29 (18) : 2130 - 2132
  • [42] Diffractive hyperchromatic objective for chromatic confocal microscopy
    Chen, Jiabin
    Li, Shaobai
    Kang, Wenjun
    Guan, Shuyuan
    Hong, Zhihan
    Liang, Rongguang
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (12): : 6834 - 6844
  • [43] Corneal thickness measurement: Disagreement between confocal microscopy and ultrasonic pachometry
    Nau, CB
    McLaren, JW
    Lee, BH
    Erie, JC
    Hodge, DO
    Bourne, WM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U25 - U25
  • [44] An improved mounting method for observation of thick specimens using confocal microscopy
    Kagayama, M
    Sasano, Y
    Hirata, M
    Mizoguchi, I
    Takahashi, I
    BIOTECHNIC & HISTOCHEMISTRY, 1996, 71 (05) : 231 - 233
  • [45] Non-contact method of thickness measurement for thin-walled rotary shell parts based on chromatic confocal sensor
    Jiao, Sicheng
    Wang, Shixiang
    Gao, Minge
    Xu, Min
    MEASUREMENT, 2024, 224
  • [46] Using chromatic confocal apparatus for in-situ rolling thickness measurement in hot embossing process
    Chen, Yi-Chang
    Dong, Shu-Ping
    Wang, Chun-Chieh
    Kuo, Shih-Hsuan
    Wang, Wei-Cheng
    Tai, Hung-Ming
    INSTRUMENTATION, METROLOGY, AND STANDARDS FOR NANOMANUFACTURING IV, 2010, 7767
  • [47] A method for measuring and adaptively correcting lens center thickness based on the chromatic confocal principle
    Zhang, Haojie
    Li, Zhisong
    Hu, Honglei
    Sun, Jiaxing
    Hou, Yuzhu
    Song, Jinlong
    RESULTS IN PHYSICS, 2024, 56
  • [48] Influence of eccentricity and tilt of radial GRIN lens on its thickness measurement by chromatic confocal technology
    Li, Chunyan
    Li, Gengpeng
    Liu, Jihong
    Luo, Dou
    Liu, Jiayi
    OPTICAL ENGINEERING, 2021, 60 (09)
  • [49] Measurement of water falling film thickness to flat plate using confocal chromatic sensoring technique
    Zhou, D. W.
    Gambaryan-Roisman, T.
    Stephan, P.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2009, 33 (02) : 273 - 283
  • [50] Measurement of thickness and profile of a transparent material using fluorescent stereo microscopy
    Hu, Zhenxing
    Xu, Tingge
    Luo, Huiyang
    Gan, Rong Z.
    Lu, Hongbing
    OPTICS EXPRESS, 2016, 24 (26): : 29823 - 29830