Correlations between central corneal power, axial length, anterior chamber depth and central corneal thickness of near-emmetropic young university students in Palestine

被引:0
|
作者
Aljarousha, Mohammed [1 ,2 ]
Daqa, Ansam A. [2 ]
Qanan, Fatma [2 ]
Murtaja, Haya [2 ]
Baraka, Nadeen [2 ]
机构
[1] Int Islamic Univ Malaysia, Fac Allied Hlth Sci, Dept Optometry & Visual Sci, Kuantan, Malaysia
[2] Islamic Univ Gaza, Fac Hlth Sci, Dept Optometry, Gaza, Palestine
来源
AFRICAN VISION AND EYE HEALTH JOURNAL | 2021年 / 80卷 / 01期
关键词
central corneal power; axial length; anterior chamber depth; ultrasonic pachymeter; automated refractometer-keratometer; corneal topography; Islamic University-Gaza; central corneal thickness; REFRACTIVE ERROR; CURVATURE; SHAPE; EYE;
D O I
10.4102/aveh.v80i1.571
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Researchers have found that the refractive states of the eye are influenced by a variety of variables. Aim: This study investigated the correlation between the central corneal power (CCP) and a number of variables, which include axial length (AL), anterior chamber depth (ACD) and the central corneal thickness (CCT) in near-emmetropic eyes of students. Setting: The study was conducted in the Optometry Laboratory of the Islamic University-Gaza (IUG), Palestine. Methods: In a prospective analysis, 200 near-emmetropic students were examined from February 2019 to May 2019 with an ultrasound scanner (A-scan), ultrasonic pachymeter and Visionix L79 automated refractometer Keratometer (ARK). Only the data of one eye were randomly chosen for investigation. Results: The means and standard deviations (s.d.) of the CCP, AL, ACD and CCT for male students (n = 97) were 43.19 dioptre (D) +/- 1.34 D, 23.54 mm +/- 0.68 mm, 3.59 mm +/- 0.26 mm and 549 mu m +/- 33 mu m, respectively. Furthermore, the means +/- s.d. of 103 female students were as follows: CCP 43.85 D +/- 1.43 D, AL 22.94 mm +/- 0.69 mm, ACD 3.35 mm +/- 0.25 mm and CCT 543 mu m +/- 35 mu m. There was a significant association between CCP and gender (p = 0.00). There was a negative significant correlation between CCP and AL for both the male (r = -0.64; p = 0.00) and the female (r = -0.71, p = 0.00) participants. Conclusion: This study provided information on CCP, AL, ACD and CCT in near-emmetropic eyes of adults. In male students, CCP was flatter and AL was longer when compared with female Palestinian students.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 30 条
  • [1] Relationship Between Central Corneal Thickness, Refractive Error, Corneal Curvature, Anterior Chamber Depth and Axial Length
    Chen, Mei-Ju
    Liu, Yin-Tzu
    Tsai, Chia-Chen
    Chen, Yen-Cheng
    Chou, Ching-Kuang
    Lee, Shu-Mei
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2009, 72 (03) : 133 - 137
  • [2] Central corneal thickness is not related to anterior scleral thickness or axial length
    Oliveira, Cristiano
    Tello, Celso
    Liebmann, Jeffrey
    Ritch, Robert
    JOURNAL OF GLAUCOMA, 2006, 15 (03) : 190 - 194
  • [3] Change in central corneal thickness, corneal endothelial cell density, anterior chamber depth and axial length after repair of rhegmatogenous retinal detachment
    Mukhtar, Ahsan
    Mehboob, Mohammad Asim
    Babar, Zaheer Uddin
    Ishaq, Mazhar
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2017, 33 (06) : 1412 - 1417
  • [4] Central corneal thickness, axial length, anterior chamber and optic disc structure in patients with central and branch retinal vein occlusion
    Vural, Gozde Sahin
    Karahan, Eyyup
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (02) : 1077 - 1083
  • [5] The comparative study of two recently developed A-scan devices:: determination of central corneal thickness, anterior chamber depth and axial length
    Sohajda, Zoltan
    Papp, Julia
    Berta, Andras
    Modis, Laszlo
    ACTA OPHTHALMOLOGICA, 2008, 86 (01) : 45 - 48
  • [6] Axial length, anterior chamber depth, lens thickness and horizontal corneal diameter in normal children
    Costa, AMC
    Calixto, N
    Milhomens, EG
    Cronemberger, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [7] Comparison of Central Corneal Thickness and Anterior Chamber Depth measured by Three Different Devices
    Shin, Minchul
    Chung, Se Yoon
    Lee, Hyo Kyung
    Hwang, Ho Sik
    Han, Kyung Eun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [8] Comparison of Anterior Chamber Depth and Central Corneal Thickness Measured Using Different Devices
    Jeung, Jae Gyun
    Gil, Tae Young
    Bae, Gi Hyun
    Shin, Seong Joo
    Chung, Sung Kun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (10): : 1570 - 1576
  • [9] Relationship between anterior chamber depth, refractive state, corneal diameter, and axial length
    Hosny, M
    Alió, JL
    Claramonte, P
    Attia, WH
    Pérez-Santonja, JJ
    JOURNAL OF REFRACTIVE SURGERY, 2000, 16 (03) : 336 - 340
  • [10] Effects of central corneal thickness, central corneal power, and axial length on intraocular pressure measurement assessed with goldmann applanation tonometry
    Fatih Özcura
    Sayime Aydın
    Nevin Uzgören
    Japanese Journal of Ophthalmology, 2008, 52 : 353 - 356