Implantable Cardioverter-Defibrillator Registry Risk Score Models for Acute Procedural Complications or Death After Implantable Cardioverter-Defibrillator Implantation

被引:70
|
作者
Haines, David E. [1 ]
Wang, Yongfei [2 ]
Curtis, Jeptha [2 ]
机构
[1] Oakland Univ, Dept Cardiovasc Med, William Beaumont Sch Med, Beaumont Hosp,Heart Rhythm Ctr, Royal Oak, MI 48073 USA
[2] Yale Univ, Sch Med, Dept Internal Med, Sect Cardiovasc Med, New Haven, CT 06510 USA
关键词
complications; death; implantable cardioverter-defibrillators; outcome assessment; registries; MYOCARDIAL-INFARCTION; RANDOMIZED-TRIAL; PACEMAKER; OUTCOMES;
D O I
10.1161/CIRCULATIONAHA.110.959676
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Patients undergoing implantable cardioverter-defibrillator (ICD) implantation are at risk of postprocedural complications. However, we do not have a risk stratification schema to identify patients at high and low risk of adverse events. Methods and Results-We analyzed data from 268 701 ICD implants submitted to the ICD Registry and developed logistic regression models to identify variables most strongly associated with the risk of acute complications and/or in-hospital death. Overall, 3.2% of the population experienced an adverse event. A simple risk score consisting of 10 readily available variables successfully identified patients at high and low risk of complications. The variables included in the score and assigned points included: age >= 70 years (1 point), female (2 points), New York Heart Association class III (1 point) or IV (3 points), atrial fibrillation (1 point), prior valve surgery (3 points), chronic lung disease (2 points), blood urea nitrogen >30 (2 points), reimplantation for reasons other than battery change (6 points), ICD type dual chamber (2 points) or biventricular (4 points), and nonelective ICD implant (3 points). The risk of any in-hospital complication increased from 0.6% among patients with a score of <= 5 (8.4% of the population) to 8.4% among patients with >= 19 risk points (3.9% of the population). Conclusions-A simple risk score consisting of readily available clinical variables can identify high-and low-risk subsets of patients undergoing ICD implantation. This information can guide the physician in patient selection and determining the intensity of care required post procedure. (Circulation. 2011;123:2069-2076.)
引用
收藏
页码:2069 / 2076
页数:8
相关论文
共 50 条
  • [21] A prophylactic implantable cardioverter-defibrillator?
    Brugada, P
    Wellens, F
    Andries, E
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 : 128 - 133
  • [22] Implantable cardioverter-defibrillator advances
    Lerman, RD
    Cannom, DS
    CURRENT OPINION IN CARDIOLOGY, 1996, 11 (01) : 16 - 22
  • [23] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    LATTUCA, J
    VELTRI, EP
    AMERICAN HEART JOURNAL, 1989, 118 (06) : 1359 - 1359
  • [24] Indications for implantable Cardioverter-Defibrillator
    Tebbenjohanns, J
    Niehaus, M
    Korte, T
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2002, 127 (41) : 2120 - 2124
  • [25] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    EPSTEIN, AE
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1991, 102 (01): : 160 - 161
  • [26] SUBDIAPHRAGMATIC IMPLANTATION OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR GENERATOR
    OBADIA, JF
    CLAUDEL, JP
    RESCIGNO, G
    KIRKORIAN, G
    HERCULE, C
    CHASSIGNOLLE, JF
    TOUBOUL, P
    ANNALS OF THORACIC SURGERY, 1995, 59 (01): : 239 - 241
  • [27] The implantable cardioverter-defibrillator: An update
    Miller, Jared D.
    Yousuf, Omair
    Berger, Ronald D.
    TRENDS IN CARDIOVASCULAR MEDICINE, 2015, 25 (07) : 606 - 611
  • [28] Implantable cardioverter-defibrillator utilization
    Camm, John
    EUROPACE, 2011, 13 (03): : 448 - 448
  • [29] Erosion of an Implantable Cardioverter-Defibrillator
    Elmouchi, Darryl
    Woelfel, Alan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (24) : E47 - E47
  • [30] Twiddling with an implantable cardioverter-defibrillator
    McCann, Conor J.
    Beelen, Roel
    Geelen, Peter
    ACTA CARDIOLOGICA, 2009, 64 (05) : 695 - 695