Resin-modified glass ionomer, modified composite or conventional glass ionomer for band cementation?: an in vitro evaluation

被引:21
|
作者
Millett, DT [1 ]
Cummings, A [1 ]
Letters, S [1 ]
Roger, E [1 ]
Love, J [1 ]
机构
[1] Glasgow Dent Hosp & Sch, Unit Orthodont, Glasgow G2 3JZ, Lanark, Scotland
关键词
D O I
10.1093/ejo/25.6.609
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aims of this study were to compare the mean shear-peel bond strength and predominant site of bond failure of micro-etched orthodontic bands cemented with resin-modified glass ionomer cement (RMGIC; Fuji Ortho LC or 3M Multi-Cure), a modified composite or a conventional GIC. The survival time of bands was also assessed following simulated mechanical stress in a ball mill. One hundred and twenty molar bands were cemented to extracted human third molars. Eighty bands (20 cemented with each cement) were used to assess the debonding force and 40 bands (10 cemented with each cement) were used to determine survival time. The specimens were prepared in accordance with the manufacturers' instructions for each cement. After storage in a humidor at 37degreesC for 24 hours, the shear debonding force was assessed for each specimen using a Nene M3000 testing machine with a crosshead speed of 1 mm/minute. The predominant site of band failure was recorded visually for all specimens as either at the band/cement or cement/enamel interface. Survival time was assessed following application of mechanical stress in a ball mill. There was no significant difference in mean shear-peel bond strength between the cement groups (P = 0.816). The proportion of specimens failing at each interface differed significantly between cement groups (P < 0.001). The predominant site of bond failure for bands cemented with the RMGIC (Fuji Ortho LC) or the modified composite was at the enamel/cement interface, whereas bands cemented with 3M Multi-Cure failed predominantly at the cement/band interface. Conventional GIC specimens failed mostly at the enamel/cement interface. The mean survival time of bands cemented with either of the RMGICs or with the modified composite was significantly longer than for those cemented with the conventional GIC. The findings indicate that although there appears to be equivalence in the mean shear-peel bond strength of the band cements assessed, the fatigue properties of the conventional GIC when subjected to simulated mechanical stress seem inferior to those of the other cements for band cementation.
引用
收藏
页码:609 / 614
页数:6
相关论文
共 50 条
  • [31] Resin-modified glass ionomer cement restorations in primary molars
    Folkesson, UH
    Andersson-Wenckert, IE
    van Dijken, JWV
    SWEDISH DENTAL JOURNAL, 1999, 23 (01) : 1 - 9
  • [32] Wear resistance of resin-modified glass ionomer cements.
    Gamou, K
    Hama, K
    Nagamine, M
    Staninec, M
    Torii, Y
    Irie, M
    Inoue, K
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 688 - 688
  • [33] Bonding amalgam to a resin-modified glass-ionomer base
    Belcher, MA
    Kunsemiller, JA
    AMERICAN JOURNAL OF DENTISTRY, 1999, 12 (06): : 305 - 308
  • [34] Clinical evaluations of resin-modified glass-ionomer restorations
    Sidhu, Sharanbir K.
    DENTAL MATERIALS, 2010, 26 (01) : 7 - 12
  • [35] In Vitro Evaluation of Microhardness of Resin-Modified Glass Ionomer Cements Subjected to a Candida albicans Biofilm
    Bertolin, Martinna Mendonca
    de Oliveira, Gigliony
    Charone, Senda
    de Araujo Soares, Rosangela Maria
    Ribeiro de Souza, Ivete Pomarico
    Portela, Maristela Barbosa
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2010, 10 (02): : 249 - 255
  • [36] Resin-modified glass ionomer cements: Bonding to enamel and dentin
    Fritz, UB
    Finger, WJ
    Uno, S
    DENTAL MATERIALS, 1996, 12 (03) : 161 - 166
  • [37] Resin-modified glass ionomer cements for bonding orthodontic retainers
    Baysal, Asli
    Uysal, Tancan
    EUROPEAN JOURNAL OF ORTHODONTICS, 2010, 32 (03) : 254 - 258
  • [38] Network competition in a resin-modified glass-ionomer cement
    Yelamanchili, A.
    Darvell, B. W.
    DENTAL MATERIALS, 2008, 24 (08) : 1065 - 1069
  • [39] DEPTH OF CURE OF RESIN-MODIFIED GLASS-IONOMER RESTORATIVES
    SWIFT, EJ
    PAWLUS, MA
    VARGAS, MA
    FORTIN, D
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 38 - 38
  • [40] SURFACE PH OF RESIN-MODIFIED GLASS POLYALKENOATE (IONOMER) CEMENTS
    WOOLFORD, MJ
    CHADWICK, RG
    JOURNAL OF DENTISTRY, 1992, 20 (06) : 359 - 364