Automatic Determination of Vertical Cup-to-Disc Ratio in Retinal Fundus Images for Glaucoma Screening

被引:24
|
作者
Guo, Jiapan [1 ]
Azzopardi, George [1 ]
Shi, Chenyu [1 ]
Jansonius, Nomdo M. [2 ]
Petkov, Nicolai [1 ]
机构
[1] Univ Groningen, Bernoulli Inst Math Comp Sci & Artificial Intelli, NL-9747 AG Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Ophthalmol, NL-9713 GW Groningen, Netherlands
来源
IEEE ACCESS | 2019年 / 7卷
关键词
Glaucoma; retinal fundus images; vertical cup-to-disk ratio; trainable COSFIRE filters; GMLVQ; OPTIC-NERVE HEAD; TRAINABLE COSFIRE FILTERS; VESSEL DELINEATION; BLOOD-VESSELS; SEGMENTATION; LOCALIZATION; PREVALENCE; CLASSIFICATION; IDENTIFICATION; RECOGNITION;
D O I
10.1109/ACCESS.2018.2890544
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Glaucoma is a chronic progressive optic neuropathy that causes visual impairment or blindness if left untreated. It is crucial to diagnose it at an early stage in order to enable treatment. Fundus photography is a viable option for population-based screening. A fundus photograph enables the observation of the excavation of the optic disk-the hallmark of glaucoma. The excavation is quantified as a vertical cup-to-disk ratio (VCDR). The manual assessment of retinal fundus images is, however, time-consuming and costly. Thus, an automated system is necessary to assist human observers. We propose a computer-aided diagnosis system, which consists of the localization of the optic disk, the determination of the height of the optic disk and the cup, and the computation of the VCDR. We evaluated the performance of our approach on eight publicly available datasets, which have, in total, 1712 retinal fundus images. We compared the obtained VCDR values with those provided by an experienced ophthalmologist and achieved a weighted VCDR mean difference of 0.11. The system provides a reliable estimation of the height of the optic disk and the cup in terms of the relative height error (RHE = 0.08 and 0.09, respectively). The Bland-Altman analysis showed that the system achieves a good agreement with the manual annotations, especially for large VCDRs which indicate pathology.
引用
收藏
页码:8527 / 8541
页数:15
相关论文
共 50 条
  • [1] Automatic Measurement of Vertical Cup-to-Disc Ratio on Retinal Fundus Images
    Hatanaka, Yuji
    Noudo, Atsushi
    Muramatsu, Chisako
    Sawada, Akira
    Hara, Takeshi
    Yamamoto, Tetsuya
    Fujita, Hiroshi
    MEDICAL BIOMETRICS, PROCEEDINGS, 2010, 6165 : 64 - +
  • [2] Automated vertical cup-to-disc ratio determination from fundus images for glaucoma detection
    Gao, Xiaoyi Raymond
    Wu, Fengze
    Yuhas, Phillip T.
    Rasel, Rafiul Karim
    Chiariglione, Marion
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [3] Vertical cup-to-disc ratio measurement for diagnosis of glaucoma on fundus images
    Hatanaka, Yuji
    Noudo, Atsushi
    Muramatsu, Chisako
    Sawada, Akira
    Hara, Takeshi
    Yamamoto, Tetsuya
    Fujita, Hiroshi
    MEDICAL IMAGING 2010: COMPUTER - AIDED DIAGNOSIS, 2010, 7624
  • [4] Automated vertical cup-to-disc ratio determination from fundus images for glaucoma detection
    Xiaoyi Raymond Gao
    Fengze Wu
    Phillip T. Yuhas
    Rafiul Karim Rasel
    Marion Chiariglione
    Scientific Reports, 14
  • [5] Automated vertical cup-to-disc ratio determination from fundus images for glaucoma detection
    Wu, Fengze
    Rasel, Rafiul Karim
    Yuhas, Phillip Thomas
    Chiariglione, Marion
    Gao, Xiaoyi Raymond
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [6] MEASUREMENT OF OPTICAL CUP-TO-DISC RATIO IN FUNDUS IMAGES FOR GLAUCOMA SCREENING
    Alghmdi, Hanan
    Tang, Hongying Lilian
    Hansen, Morten
    O'Shea, Arrianne
    Al Turk, Lutfiah
    Peto, Tunde
    2015 INTERNATIONAL WORKSHOP ON COMPUTATIONAL INTELLIGENCE FOR MULTIMEDIA UNDERSTANDING (IWCIM), 2015,
  • [7] Automated Measurement of Cup-to-Disc Ratio for Diagnosing Glaucoma in Retinal Fundus Images
    Hatanaka, Y.
    Fukuta, K.
    Muramatsu, C.
    Sawada, A.
    Hara, T.
    Yamamoto, T.
    Fujita, H.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 11: BIOMEDICAL ENGINEERING FOR AUDIOLOGY, OPHTHALMOLOGY, EMERGENCY AND DENTAL MEDICINE, 2009, 25 (11): : 198 - +
  • [8] Automatic Measurement of Cup-to-Disc Ratio for Retinal Images
    Zhao, Xin
    Guo, Fan
    Zou, Beiji
    Liu, Xiyao
    Zhao, Rongchang
    PATTERN RECOGNITION AND COMPUTER VISION (PRCV 2018), PT I, 2018, 11256 : 453 - 465
  • [9] Optic cup and disk extraction from retinal fundus images for determination of cup-to-disc ratio
    Liu, J.
    Wong, D. W. K.
    Lim, J. H.
    Jia, X.
    Yin, F.
    Li, H.
    Xiong, W.
    Wong, T. Y.
    ICIEA 2008: 3RD IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, PROCEEDINGS, VOLS 1-3, 2008, : 1828 - +
  • [10] Automatic Measurement of Cup to Disc Ratio for Diagnosis of Glaucoma on Retinal Fundus Images
    Poshtyar, Azin
    Shanbehzadeh, Jamshid
    Ahmadieh, Hamid
    PROCEEDINGS OF THE 2013 6TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2013), VOLS 1 AND 2, 2013, : 24 - 27