Umbilical venous volume flow and fetal behavioral states in the normally developing fetus

被引:17
|
作者
Boito, SME
Ursem, NTC
Struijk, PC
Stijnen, T
Wladimiroff, JW
机构
[1] Erasmus MC, Dept Obstet & Gynaecol, NL-3015 GD Rotterdam, Netherlands
[2] Erasmus MC, Dept Epidemiol & Biostat, Rotterdam, Netherlands
关键词
fetal behavioral states; normal human pregnancy; umbilical venous volume blood flow;
D O I
10.1002/uog.956
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To determine the relationship between umbilical venous (UV) volume flow and fetal behavioral states 1F (quiet sleep) and 2F (active sleep) in normal pregnancies at 36-40 weeks of gestation. Methods Fetal behavioral states were established in 17 normal pregnancies by means of combined assessment of fetal heart rate patterns (FHRP), and fetal eye and body movements. UV vessel area (mm(2)) as obtained by tracing the inner vessel area using Labview and Imaq Vision software and UV time-averaged flow velocity (mm/s Doppler) were multiplied to calculate UV volume flow (mL/min) including flow/kg fetus. The pulsatility index (PI) in the umbilical artery was also determined. In each woman, all parameters were measured between three and five times in each behavioral state. Data are reported as mean +/-1 SD and analyzed by paired t-test. Results No statistically significant behavioral-state-related changes were observed for UV time-averaged velocity and UV volume flow, resulting in UV volume flow/kg fetus of 69.1 +/- 14.9 mL/min*kg at 1F and 71.6 +/- 12.1 mL/min*kg at 2F (not significant). A statistically significant increase (P = 0.02) was established for UV cross-sectional area (46.4 +/- 8.6 mm(2) VS. 49.0 +/- 10.1 mm(2)) and for fetal heart rate (FHR) from 134.2 +/- 10.3 bpm in 1F to 144.2 +/- 7 bpm in 2F. Umbilical artery PI was not significantly different between the two behavioral states. Conclusions On the basis of high venous vessel wall compliance, the significant increase in UV cross-sectional area during fetal behavioral state 2F may be determined by a rise in mean venous pressure. The significant rise in FHR may reflect increased fetal cardiac output during state 2F while the resistance at the hepato-ductal pathway remains relatively constant with the purpose of meeting raised energy demands during the active sleep state. This is further supported by the observed trend towards an increase in UV volume flow. Copyright (C) 2004 ISUOG. Published by John Wiley Sons, Ltd.
引用
收藏
页码:138 / 142
页数:5
相关论文
共 50 条
  • [41] Doppler measurement of blood volume flow in the fetal and umbilical arteries of small for gestational age fetuses
    Kassanos, D
    Salamalekis, E
    Loghis, C
    Vitoratos, N
    Panayotopoulos, N
    Creatsas, G
    FETUS AS A PATIENT, 2000, : 381 - 383
  • [42] Re: Fetal brain/liver volume ratio and umbilical volume flow parameters relative to normal and abnormal human development
    DuBose, TJ
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2004, 23 (02) : 205 - 206
  • [43] Umbilical venous diameter and flow in monochorionic diamniotic twin pregnancy: association with placental sharing and fetal demise
    Couck, I
    van der Merwe, J.
    Russo, F.
    Richter, J.
    Aertsen, M.
    Cauwberghs, B.
    Van Aelst, M.
    Lewi, L.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2022, 60 (04) : 514 - 522
  • [44] THE UMBILICAL ARTERY FLOW VELOCITY WAVE-FORM IN RELATION TO FETAL BREATHING MOVEMENTS, FETAL HEART-RATE AND FETAL BEHAVIORAL STATES IN NORMAL-PREGNANCY AT 37-39 WEEKS
    MULDERS, LGM
    MUIJSERS, GJJM
    JONGSMA, HW
    NIJHUIS, JG
    HEIN, PR
    EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1987, 26 (02): : 201 - 201
  • [45] UMBILICAL VENOUS-BLOOD FLOW AND ITS DISTRIBUTION BEFORE AND DURING AUTONOMIC BLOCKADE IN FETAL LAMBS
    EDELSTONE, DI
    MERICK, RE
    CARITIS, SN
    MUELLERHEUBACH, E
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1980, 138 (06) : 703 - 707
  • [46] RELATIONSHIP BETWEEN UMBILICAL AND FETAL CEREBRAL BLOOD-FLOW VELOCITY WAVE-FORMS AND UMBILICAL VENOUS-BLOOD GASES
    BONNIN, P
    GUYOT, B
    BAILLIART, O
    BENARD, C
    BLOT, P
    MARTINEAUD, JP
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1992, 2 (01) : 18 - 22
  • [47] DOPPLER COLOR-FLOW IMAGING OF FETAL INTRACEREBRAL ARTERIES AND UMBILICAL ARTERY IN THE SMALL-FOR-GESTATIONAL-AGE FETUS
    PAULIN, F
    SZABO, I
    RIGO, J
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1995, 102 (02): : 174 - 174
  • [48] DOPPLER COLOR-FLOW IMAGING OF FETAL INTRACEREBRAL ARTERIES AND UMBILICAL ARTERY IN THE SMALL-FOR-GESTATIONAL-AGE FETUS
    NOORDAM, MJ
    HEYDANUS, R
    HOP, WCJ
    HOEKSTRA, FME
    WLADIMIROFF, JW
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1994, 101 (06): : 504 - 508
  • [49] Prediction of Fetal Growth Restriction for Fetal Umbilical Arterial/Venous Blood Flow Index Evaluated by Ultrasonic Doppler under Intelligent Algorithm
    Yu, Xinying
    Yao, Ye
    Wang, Dan
    Tang, Jiani
    Lu, Jing
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2022, 2022
  • [50] THE UMBILICAL ARTERY BLOOD-FLOW VELOCITY WAVE-FORM IN RELATION TO FETAL BREATHING MOVEMENTS, FETAL HEART-RATE AND FETAL BEHAVIORAL STATES IN NORMAL-PREGNANCY AT 37 TO 39 WEEKS
    MULDERS, LGM
    MUIJSERS, GJJM
    JONGSMA, HW
    NIJHUIS, JG
    HEIN, PR
    EARLY HUMAN DEVELOPMENT, 1986, 14 (3-4) : 283 - 293