Visualized experimental investigation on cross-flow indirect evaporative cooler with condensation

被引:33
|
作者
Meng, Dandong [1 ]
Lv, Jian [1 ]
Chen, Yi [2 ]
Li, Han [1 ]
Ma, Xuejian [1 ]
机构
[1] Tianjin Chengjian Univ, Sch Energy & Safety Engn, Tianjin 300384, Peoples R China
[2] Technol & Higher Educ Inst Hong Kong, Fac Sci & Technol, Hong Kong, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Visualized experiment; Indirect evaporative cooler; Turning point; Condensation; COOLING SYSTEM; MASS-TRANSFER; ANALYTICAL-MODEL; THERMAL COMFORT; PERFORMANCES; CLIMATE;
D O I
10.1016/j.applthermaleng.2018.09.026
中图分类号
O414.1 [热力学];
学科分类号
摘要
In hot and humid regions, condensation will easily occur in the dry channels of indirect evaporative cooler (IEC) due to high dew point temperature of primary air. However, the visualized investigation on cross-flow IEC with condensation has seldom been reported by previous studies. Therefore, a visualized cross-flow IEC was constructed with a transparent cover plate for observing the. condensation in a primary air channels. A series of experiment had been carried out to investigate the comprehensive performance of IEC under different inlet primary air temperature and humidity. The outlet primary air temperature, wb-effectiveness, water consumption rate, heat transfer rate and condensation rate were analysed in detail under non-condensation, partial condensation and total condensation cases. The experimental results showed that the turning point from non condensation to partial condensation was 33.0 degrees C under relative humidity of 50%, 29.0 degrees C under relative humidity of 60% and partial condensation to total condensation was 35.0 degrees C under relative humidity of 70%, 30.0 degrees C under relative humidity of 80%, respectively. Condensation improved the outlet primary air temperature, total heat transfer, water consumption rate and condensation rate but lowered the wb-effectiveness. Furthermore, the thermal resistance of condensate film was non-ignorable because of thick water film.
引用
收藏
页码:165 / 173
页数:9
相关论文
共 50 条
  • [41] Numerical investigation of the heat and mass transfer process within a cross-flow indirect evaporative cooling system for hot and humid climates
    Adam, Abdalazeem
    Han, Dong
    He, Weifeng
    Amidpour, Majid
    Zhong, Hong
    JOURNAL OF BUILDING ENGINEERING, 2022, 45
  • [42] Experimental investigation of in-line and cross-flow VIV
    Soreide, M
    PROCEEDINGS OF THE THIRTEENTH (2003) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 3, 2003, : 585 - 592
  • [43] EXPERIMENTAL AND SEMIANALYTICAL INVESTIGATION OF DROPLET DEFORMATION IN A CROSS-FLOW
    Joshi, Sumit
    Anand, T. N. C.
    ATOMIZATION AND SPRAYS, 2019, 29 (09) : 841 - 859
  • [44] An Experimental Investigation of the Performance of Cross-flow Hydro Turbines
    Verma, Vinay
    Gaba, Vivek Kumar
    Bhowmick, Shubhankar
    POWER AND ENERGY SYSTEMS ENGINEERING, (CPESE 2017), 2017, 141 : 630 - 634
  • [45] Experimental investigation of water spraying in an indirect evaporative cooler from nozzle type and spray strategy perspectives
    Sun, Tiezhu
    Huang, Xiang
    Chen, Yi
    Zhang, Hong
    ENERGY AND BUILDINGS, 2020, 214
  • [46] Numerical and experimental investigation of a cross-flow water turbine
    Sammartano, Vincenzo
    Morreale, Gabriele
    Sinagra, Marco
    Tucciarelli, Tullio
    JOURNAL OF HYDRAULIC RESEARCH, 2016, 54 (03) : 321 - 331
  • [47] Parameter sensitivity analysis of indirect evaporative cooler (IEC) with condensation from primary air
    Chen, Yi
    Yang, Hongxing
    Luo, Yimo
    CUE 2015 - APPLIED ENERGY SYMPOSIUM AND SUMMIT 2015: LOW CARBON CITIES AND URBAN ENERGY SYSTEMS, 2016, 88 : 498 - 504
  • [48] Thermal performance analysis of a mixed-flow indirect evaporative cooler
    Deepak, C.
    Naik, Rudra
    Godi, Sangamesh C.
    Mangrulkar, Chidanand K.
    Prashanth, H. K.
    APPLIED THERMAL ENGINEERING, 2022, 217
  • [49] AN EXPERIMENTAL INVESTIGATION OF MERGING BUOYANT JETS IN A CROSS-FLOW
    GREGORIC, M
    DAVIS, LR
    BUSHNELL, DJ
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1982, 104 (02): : 236 - 240
  • [50] Parameter sensitivity analysis and configuration optimization of indirect evaporative cooler (IEC) considering condensation
    Chen, Yi
    Yang, Hongxing
    Luo, Yimo
    APPLIED ENERGY, 2017, 194 : 440 - 453