Visualized experimental investigation on cross-flow indirect evaporative cooler with condensation

被引:33
|
作者
Meng, Dandong [1 ]
Lv, Jian [1 ]
Chen, Yi [2 ]
Li, Han [1 ]
Ma, Xuejian [1 ]
机构
[1] Tianjin Chengjian Univ, Sch Energy & Safety Engn, Tianjin 300384, Peoples R China
[2] Technol & Higher Educ Inst Hong Kong, Fac Sci & Technol, Hong Kong, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Visualized experiment; Indirect evaporative cooler; Turning point; Condensation; COOLING SYSTEM; MASS-TRANSFER; ANALYTICAL-MODEL; THERMAL COMFORT; PERFORMANCES; CLIMATE;
D O I
10.1016/j.applthermaleng.2018.09.026
中图分类号
O414.1 [热力学];
学科分类号
摘要
In hot and humid regions, condensation will easily occur in the dry channels of indirect evaporative cooler (IEC) due to high dew point temperature of primary air. However, the visualized investigation on cross-flow IEC with condensation has seldom been reported by previous studies. Therefore, a visualized cross-flow IEC was constructed with a transparent cover plate for observing the. condensation in a primary air channels. A series of experiment had been carried out to investigate the comprehensive performance of IEC under different inlet primary air temperature and humidity. The outlet primary air temperature, wb-effectiveness, water consumption rate, heat transfer rate and condensation rate were analysed in detail under non-condensation, partial condensation and total condensation cases. The experimental results showed that the turning point from non condensation to partial condensation was 33.0 degrees C under relative humidity of 50%, 29.0 degrees C under relative humidity of 60% and partial condensation to total condensation was 35.0 degrees C under relative humidity of 70%, 30.0 degrees C under relative humidity of 80%, respectively. Condensation improved the outlet primary air temperature, total heat transfer, water consumption rate and condensation rate but lowered the wb-effectiveness. Furthermore, the thermal resistance of condensate film was non-ignorable because of thick water film.
引用
收藏
页码:165 / 173
页数:9
相关论文
共 50 条
  • [1] Development of an experimental validated model of cross-flow indirect evaporative cooler with condensation
    Zheng, Bin
    Guo, Chunmei
    Chen, Tong
    Shi, Qi
    Lv, Jian
    You, Yuwen
    APPLIED ENERGY, 2019, 252
  • [2] Modelling and experimental investigation of the cross-flow dew point evaporative cooler with and without dehumidification
    Lin, J.
    Wang, R. Z.
    Kumja, M.
    Bui, T. D.
    Chua, K. J.
    APPLIED THERMAL ENGINEERING, 2017, 121 : 1 - 13
  • [3] An improved indirect evaporative cooler experimental investigation
    Shahzad, Muhammad Wakil
    Burhan, Muhammad
    Ybyraiymkul, Doskhan
    Oh, Seung Jin
    Ng, Kim Choon
    APPLIED ENERGY, 2019, 256
  • [4] Numerical study and optimization of the cross-flow Maisotsenko cycle indirect evaporative air cooler
    Pandelidis, Demis
    Anisimov, Sergey
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 103 : 1029 - 1041
  • [5] Numerical study on parametric correlations and regional applicability of a cross-flow indirect evaporative cooler
    Gao, Wenxue
    Yang, Mingchang
    Wang, Yan
    Yang, Lin
    Miao, Qingwei
    Yan, Rongsong
    Hu, Yingjie
    JOURNAL OF BUILDING ENGINEERING, 2024, 97
  • [6] Characteristics of primary air condensation in indirect evaporative cooler: Theoretical analysis and visualized validation
    Min, Yunran
    Chen, Yi
    Yang, Hongxing
    Guo, Chunmei
    BUILDING AND ENVIRONMENT, 2020, 174 (174)
  • [7] Experimental study on a cross-flow regenerative indirect evaporative cooling system
    Cui, Xin
    Tian, Wei
    Yang, Xiaohu
    Kong, Qiongxiang
    Chai, Yue
    Jin, Liwen
    CLEANER ENERGY FOR CLEANER CITIES, 2018, 152 : 395 - 400
  • [8] Performance measurement of a cross-flow indirect evaporative cooler: Effect of water nozzles and airflows arrangement
    De Antonellis, Stefano
    Joppolo, Cesare Maria
    Liberati, Paolo
    ENERGY AND BUILDINGS, 2019, 184 : 114 - 121
  • [9] Numerical analysis of cross-flow plate type indirect evaporative cooler: Modeling and parametric analysis
    Adam, Abdalazeem
    Han, Dong
    He, Weifeng
    Chen, Junjie
    APPLIED THERMAL ENGINEERING, 2021, 185
  • [10] Energetic and exergetic performance investigation of a cross-flow regenerative indirect evaporative cooler made up of aluminium plate heat exchangers
    Inanli, Mert
    Aydin, Devrim
    Rezaei, Marzieh
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2023, 238 (06) : 2821 - 2833