Study well-shaped germanium detectors for low-background counting

被引:0
|
作者
Wei, W. -Z. [1 ]
Mei, D. -M. [1 ,2 ]
Zhang, C. [1 ]
机构
[1] Univ S Dakota, Dept Phys, Vermillion, SD 57069 USA
[2] Yangtze Univ, Sch Phys & Optoelect, Jingzhou 434023, Peoples R China
关键词
D O I
10.1088/1742-6596/606/1/012019
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Radiogenic particles are known as the main sources of background for all ultra-low background experiments in the detection of dark matter and neutrino properties. In particular, the radiogenic gamma rays from PMTs are a main component of the observed backgrounds in the noble liquid detectors such as XENON100 and LUX. This suggests a more accurate screening of PMTs is needed for the next generation experiments such as LUX-Zplin or Xenon1T. Hence, we propose to develop well-shaped germanium detectors for a better understanding of the radiogenic background from PMTs. A well-shaped germanium detector array and PMT (R11410MOD) have been designed in a Geant4-based Monte Carlo simulation, in which three radiogenic background isotopes from U-238, Th-232 and K-40 have been studied. In this work, we show the detector performance including the detector efficiency, energy resolution and the detector sensitivity for low-background counting in the detection of rare event physics.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Low-background monitoring cameras for the Daya Bay Antineutrino Detectors
    Band, H. R.
    Cherwinka, J. J.
    Heeger, K. M.
    Hinrichs, P.
    McFarlane, M. C.
    Wang, W.
    Webber, D. M.
    Wise, T.
    Xiao, Q.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [32] Astroparticle Physics with a Customized Low-Background Broad Energy Germanium Detector
    Finnerty, Padraic
    Collar, Juan I.
    Giovanetti, Graham K.
    Henning, Reyco
    Marino, Michael G.
    Schubert, Alexis G.
    Wilkerson, John F.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 671 - 673
  • [33] A cryogenic low-background low-noise CMOS preamplifier for HPGe detectors
    Hao, J.
    He, L.
    Deng, Z.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (06)
  • [34] LOW-BACKGROUND GERMANIUM SPECTROMETRY - THE BOTTOM LINE 3 YEARS LATER
    BRODZINSKI, RL
    MILEY, HS
    REEVES, JH
    AVIGNONE, FT
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1995, 193 (01): : 61 - 70
  • [35] Astroparticle physics with a customized low-background broad energy Germanium detector
    Aalseth, C. E.
    Amman, M.
    Avignone, F. T., III
    Back, H. O.
    Barabash, A. S.
    Barbeau, P. S.
    Bergevin, M.
    Bertrand, F. E.
    Boswell, M.
    Brudanin, V.
    Bugg, W.
    Burritt, T. H.
    Busch, M.
    Capps, G.
    Chan, Y. -D.
    Collar, J. I.
    Cooper, R. J.
    Creswick, R.
    Detwiler, J. A.
    Diaz, J.
    Doe, P. J.
    Efremenko, Yu.
    Egorov, V.
    Ejiri, H.
    Elliott, S. R.
    Ely, J.
    Esterline, J.
    Farach, H.
    Fast, J. E.
    Fields, N.
    Finnerty, P.
    Fujikawa, B.
    Fuller, E.
    Gehman, V. M.
    Giovanetti, G. K.
    Guiseppe, V. E.
    Gusey, K.
    Hallin, A. L.
    Harper, G. C.
    Hazama, R.
    Henning, R.
    Hime, A.
    Hoppe, E. W.
    Hossbach, T. W.
    Howe, M. A.
    Johnson, R. A.
    Keeter, K. J.
    Keillor, M.
    Keller, C.
    Kephart, J. D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 692 - 695
  • [36] A LOW-BACKGROUND BETA-COUNTING APPARATUS WITH A TRANSISTORIZED ANTICOINCIDENCE CIRCUIT
    BLINOV, VA
    KUZNETSO.MI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1966, (02): : 336 - &
  • [37] A 222Rn source for low-background liquid scintillation detectors
    Johnson, M
    Benziger, J
    Stoia, C
    Calaprice, F
    Chen, M
    Darnton, N
    Loeser, F
    Vogelaar, RB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 414 (2-3): : 459 - 465
  • [38] Gator: a low-background counting facility at the Gran Sasso Underground Laboratory
    Baudis, L.
    Ferella, A. D.
    Askin, A.
    Angle, J.
    Aprile, E.
    Bruch, T.
    Kish, A.
    Laubenstein, M.
    Manalaysay, A.
    Undagoitia, T. Marrodan
    Schumann, M.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [39] Evaluation and lifetime study of a cryogenic SAR ADC for HPGe detectors in low-background physics experiments
    Liu, F.
    Xue, T.
    Deng, Z.
    Liu, Y.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (07)
  • [40] A novel low-background photomultiplier tube developed for xenon based detectors
    Yun, Youhui
    Zhou, Zhizhen
    An, Baoguo
    Gao, Zhixing
    Han, Ke
    Liu, Jianglai
    Liang, Yuanzi
    Liu, Yang
    Meng, Yue
    Qian, Zhicheng
    Shang, Xiaofeng
    Si, Lin
    Song, Ziyan
    Wang, Hao
    Wang, Mingxin
    Wang, Shaobo
    Wu, Liangyu
    Wu, Weihao
    Wu, Yuan
    Yan, Binbin
    Yan, Xiyu
    Yuan, Zhe
    Zhang, Tao
    Zhao, Qiang
    Zeng, Xinning
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2025, 1073