Study well-shaped germanium detectors for low-background counting

被引:0
|
作者
Wei, W. -Z. [1 ]
Mei, D. -M. [1 ,2 ]
Zhang, C. [1 ]
机构
[1] Univ S Dakota, Dept Phys, Vermillion, SD 57069 USA
[2] Yangtze Univ, Sch Phys & Optoelect, Jingzhou 434023, Peoples R China
关键词
D O I
10.1088/1742-6596/606/1/012019
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Radiogenic particles are known as the main sources of background for all ultra-low background experiments in the detection of dark matter and neutrino properties. In particular, the radiogenic gamma rays from PMTs are a main component of the observed backgrounds in the noble liquid detectors such as XENON100 and LUX. This suggests a more accurate screening of PMTs is needed for the next generation experiments such as LUX-Zplin or Xenon1T. Hence, we propose to develop well-shaped germanium detectors for a better understanding of the radiogenic background from PMTs. A well-shaped germanium detector array and PMT (R11410MOD) have been designed in a Geant4-based Monte Carlo simulation, in which three radiogenic background isotopes from U-238, Th-232 and K-40 have been studied. In this work, we show the detector performance including the detector efficiency, energy resolution and the detector sensitivity for low-background counting in the detection of rare event physics.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] LOW-BACKGROUND COUNTING SYSTEMS COMPARED
    MILEY, HS
    BRODZINSKI, RL
    REEVES, JH
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1992, 160 (02): : 371 - 385
  • [2] A CONCRETE LOW-BACKGROUND COUNTING ENCLOSURE
    WOLLENBERG, HA
    SMITH, AR
    HEALTH PHYSICS, 1966, 12 (01): : 53 - +
  • [3] LOW-BACKGROUND BETA COUNTING ARRANGEMENT
    GYONYOR, B
    ACTA PHYSICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1974, 35 (1-4): : 131 - 139
  • [4] LOW-BACKGROUND COUNTING USING GE(LI) DETECTORS WITH ANTI-MUON-SHIELDS
    MULLER, G
    WISSMANN, F
    SCHRODER, F
    MONDRY, G
    BRINKMANN, HJ
    SMEND, F
    SCHUMACHER, M
    FETTWEIS, P
    CARCHON, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 295 (1-2): : 133 - 139
  • [5] LOW-BACKGROUND GERMANIUM SPECTROMETRY - THE BOTTOM LINE
    BRODZINSKI, RL
    MILEY, HS
    REEVES, JH
    AVIGNONE, FT
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1992, 160 (02): : 355 - 362
  • [6] Design and Characterization of a Low-Noise and Low-Background Charge Sensitive Amplifier for the Readout of Germanium Detectors
    Butta, D.
    Borghi, G.
    Carminati, M.
    Ferrari, G.
    Gieb, A.
    Henkes, F.
    Willers, M.
    Mertens, S.
    Riboldi, S.
    Fiorini, C.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2024, 71 (09) : 2171 - 2179
  • [7] The upgraded low-background germanium counting facility Gator for high-sensitivity ?-ray spectrometry
    Araujo, Gabriela R.
    Baudis, Laura
    Biondi, Yanina
    Bismark, Alexander
    Galloway, Michelle
    JOURNAL OF INSTRUMENTATION, 2022, 17 (08)
  • [8] Theory of photoresponse of low-background IR detectors
    Fouks, BI
    INFRARED SPACEBORNE REMOTE SENSING V, 1997, 3122 : 441 - 452
  • [9] LARGE, LOW-BACKGROUND WELL-TYPE DETECTORS FOR MEASUREMENTS OF ENVIRONMENTAL-RADIOACTIVITY
    REYSS, JL
    SCHMIDT, S
    LEGELEUX, F
    BONTE, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 357 (2-3): : 391 - 397